HSHuma Saleem

Huma Saleem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huma Saleem has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enteral Nutrition Delivery Methods and Clinical Outcomes in Critically Ill Patients: A Retrospective Cohort Study

    by Yekta Jalaeian, Huma Saleem, Seda Akben, Abdolvahab Khademi, Nicole Behrooz, Anoeil Odisho, Laura Wrightwood, Sanjana Varghese, Hayley Abell, Eduard Shaykhinurov, et al.

    Background: Adequate enteral nutrition is essential in critical illness, yet optimal delivery strategies remain debated. Rate-based and volume-based are commonly used, with prior studies suggesting improved caloric delivery with volume-based. However, real-world clinical outcomes, particularly with mixed protocols and in COVID-19 patients, are unclear. We hypothesized that volume-based would improve caloric delivery versus rate-based or mixed, and that critically ill COVID-19 patients would achieve a lower goal intake. Methods: This single-center retrospective cohort study included ICU patients (2020-2023) receiving ≥48 h of enteral nutrition via rate-based, volume-based, or mixed strategies. The primary outcome was the percentage of prescribed intake achieved. Secondary outcomes included hospital and ICU length of stay, ventilator days, hospital-acquired pressure injuries and infections. Baseline illness severity was assessed using standard comorbidity and organ failure scores. Results: Among 324 patients, 24% achieved ≥80% of caloric goal, with no difference across feeding strategies ( P = .30). Mixed feeding was associated with longer hospital and ICU stays, more ventilator days, and longer enteral nutrition duration (all P < .01). Mixed feeding was associated with higher pressure injury compared with rate-based (30% vs 16%, P = .03), with no association with hospital-acquired infections. Among patients achieving ≥80% prescribed intake, associations with ICU length of stay and ventilator days were no longer significant. COVID-19 status did not modify these associations, with longer stays in COVID-positive patients receiving mixed protocol. Conclusions: Volume-based did not improve total energy delivery. Mixed feeding was associated with worse clinical outcomes, likely reflecting greater illness complexity rather than causation. Consistency of nutrition delivery may be more important than protocol type. Prospective multicenter studies are needed.

  • Authors' Response to Letter to the Editor

    by Brendan Sweeney, Justin Kim, Ariana Adnani, Huma Saleem, Seda Akben, Yin Rong Alvina Teo, Eduard Shaykhinurov, Maria Wu, Rishika Bheem, Samita Islam, et al.

  • Midline Catheters as an Alternative for Central Venous Catheters in Venous Pressure Monitoring: A Single Center Experience

    by Brendan Sweeney, Justin Kim, Ariana Adnani, Huma Saleem, Seda Akben, Yin Rong Alvina Teo, Eduard Shaykhinurov, Maria Wu, Rishika Bheem, Samita Islam, et al.

    Purpose: Midline catheters (ML) are long peripheral intravenous catheters placed in an upper extremity above the antecubital fossa via the basilic, cephalic, or brachial veins. These provide safe and comfortable long-term vascular access for critically ill patients. Central venous pressures (CVP) are obtained from central venous catheters (CVC) and are often used as resuscitation parameters. Given the proximity of ML to the axillary vein, we investigated if midline venous pressure (MVP) is comparable to CVP. Methods: This is an observational study conducted in adult critical care patients at a tertiary academic center. Inclusion criteria were patients with a CVC in the subclavian or internal jugular veins and a ML in place as part of standard ICU care. Pressure measurements were recorded from both catheters every 15 min over a 60-min period. Demographic, clinical, and physiological data points were collected. Continuous variables were analyzed using the t-test. Pearson correlation was used to evaluate the relationship between the paired variables. Results: We enrolled 50 patients with 5 pressure measurements taken per patient (n = 250). The mean MVP and CVP were 10.6 ± 6.4 mm Hg and 9.1 ± 6.3 mm Hg, respectively ( P < .001). In Bland Altman analysis, the mean bias was −1.48 ± 3.99 mm Hg with limits of agreement of −9.3 mm Hg to 6.3 mm Hg. The Pearson correlation coefficient was 0.8 ( P < .001). Conclusions: Our study investigated MVP as a correlate of CVP. Our results show a mean bias of −1.48 ± 3.99 mm Hg and a strong positive Pearson correlation coefficient of 0.8 between the MVP and the CVP. The large limits of agreement indicate MVP and CVP are not interchangeable. Despite this, clinically significant pressure values from CVCs and MLs trend similarly.