Barkin Buyukcakir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Barkin Buyukcakir has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Dirk Vandermeulen
Department of Electrical Engineering (ESAT) - Processing Speech and Images (PSI), KU Leuven, Leuven, Belgium
4 shared publicationsPeter Claes
Department of Electrical Engineering (ESAT) - Processing Speech and Images (PSI), KU Leuven, Leuven, Belgium
4 shared publicationsJannick De Tobel
Department of Diagnostic Sciences, Ghent University, Ghent, Belgium
3 shared publicationsPatrick Thevissen
Imaging and Pathology - Forensic Odontology Department, KU Leuven, Leuven, Belgium
3 shared publications- Dirk Vandermeulen
KU Leuven
2 shared publications - Jannick De Tobel
Ghent University
2 shared publications
Latest Publications
- 11 February 2026
- Published by Springer Nature
- p. 154-176
Attention Maps in 3D Shape Classification for Dental Stage Estimation with Class Node Graph Attention Networks
- 11 February 2026
- Published by Springer Nature
- p. 154-176
Attention Maps in 3D Shape Classification for Dental Stage Estimation with Class Node Graph Attention Networks
- Open Access
- 26 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 42076
An autoencoder and vision transformer based interpretability analysis on the performance differences in automated staging of second and third molars
The practical adoption of deep learning in high-stakes forensic applications, such as dental age estimation, is often limited by the ‘black box’ nature of the models. This study introduces a framework designed to enhance both performance and transparency in this context. We use a notable performance disparity in the automated staging of mandibular second (tooth 37) and third (tooth 38) molars as a case study. The proposed framework, which combines a convolutional autoencoder (AE) with a Vision Transformer (ViT), improves classification accuracy for both teeth over a baseline ViT, increasing from 0.712 to 0.815 for tooth 37 and from 0.462 to 0.543 for tooth 38. Beyond improving performance, the framework provides multi-faceted diagnostic insights. Analysis of the AE’s latent space metrics and image reconstructions indicates that the remaining performance gap is data-centric, suggesting high intra-class morphological variability in the tooth 38 dataset is a primary limiting factor. This work highlights the insufficiency of relying on a single mode of interpretability, such as attention maps, which can appear anatomically plausible yet fail to identify underlying data issues. By offering a methodology that both enhances accuracy and provides evidence for why a model may be uncertain, this framework serves as a more robust tool to support expert decision-making in forensic age estimation.
- 26 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 42076
Open AccessAn autoencoder and vision transformer based interpretability analysis on the performance differences in automated staging of second and third molars
The practical adoption of deep learning in high-stakes forensic applications, such as dental age estimation, is often limited by the ‘black box’ nature of the models. This study introduces a framework designed to enhance both performance and transparency in this context. We use a notable performance disparity in the automated staging of mandibular second (tooth 37) and third (tooth 38) molars as a case study. The proposed framework, which combines a convolutional autoencoder (AE) with a Vision Transformer (ViT), improves classification accuracy for both teeth over a baseline ViT, increasing from 0.712 to 0.815 for tooth 37 and from 0.462 to 0.543 for tooth 38. Beyond improving performance, the framework provides multi-faceted diagnostic insights. Analysis of the AE’s latent space metrics and image reconstructions indicates that the remaining performance gap is data-centric, suggesting high intra-class morphological variability in the tooth 38 dataset is a primary limiting factor. This work highlights the insufficiency of relying on a single mode of interpretability, such as attention maps, which can appear anatomically plausible yet fail to identify underlying data issues. By offering a methodology that both enhances accuracy and provides evidence for why a model may be uncertain, this framework serves as a more robust tool to support expert decision-making in forensic age estimation.
- Open Access
An Autoencoder and Vision Transformer-based Interpretability Analysis of the Differences in Automated Staging of Second and Third Molars
The practical adoption of deep learning in high-stakes forensic applications, such as dental age estimation, is often limited by the 'black box' nature of the models. This study introduces a framework designed to enhance both performance and transparency in this context. We use a notable performance disparity in the automated staging of mandibular second (tooth 37) and third (tooth 38) molars as a case study. The proposed framework, which combines a convolutional autoencoder (AE) with a Vision Transformer (ViT), improves classification accuracy for both teeth over a baseline ViT, increasing from 0.712 to 0.815 for tooth 37 and from 0.462 to 0.543 for tooth 38. Beyond improving performance, the framework provides multi-faceted diagnostic insights. Analysis of the AE's latent space metrics and image reconstructions indicates that the remaining performance gap is data-centric, suggesting high intra-class morphological variability in the tooth 38 dataset is a primary limiting factor. This work highlights the insufficiency of relying on a single mode of interpretability, such as attention maps, which can appear anatomically plausible yet fail to identify underlying data issues. By offering a methodology that both enhances accuracy and provides evidence for why a model may be uncertain, this framework serves as a more robust tool to support expert decision-making in forensic age estimation.
Open AccessAn Autoencoder and Vision Transformer-based Interpretability Analysis of the Differences in Automated Staging of Second and Third Molars
The practical adoption of deep learning in high-stakes forensic applications, such as dental age estimation, is often limited by the 'black box' nature of the models. This study introduces a framework designed to enhance both performance and transparency in this context. We use a notable performance disparity in the automated staging of mandibular second (tooth 37) and third (tooth 38) molars as a case study. The proposed framework, which combines a convolutional autoencoder (AE) with a Vision Transformer (ViT), improves classification accuracy for both teeth over a baseline ViT, increasing from 0.712 to 0.815 for tooth 37 and from 0.462 to 0.543 for tooth 38. Beyond improving performance, the framework provides multi-faceted diagnostic insights. Analysis of the AE's latent space metrics and image reconstructions indicates that the remaining performance gap is data-centric, suggesting high intra-class morphological variability in the tooth 38 dataset is a primary limiting factor. This work highlights the insufficiency of relying on a single mode of interpretability, such as attention maps, which can appear anatomically plausible yet fail to identify underlying data issues. By offering a methodology that both enhances accuracy and provides evidence for why a model may be uncertain, this framework serves as a more robust tool to support expert decision-making in forensic age estimation.
- Open Access
- 26 May 2025
- Published by Springer Nature in Research Square
Differences in Automated Staging of Second and Third Molars: An Autoencoder and Vision Transformer-based Interpretability Analysis
Dental age estimation is a critical part of forensic odontology applications. It is conventionally carried out by experts on dental orthopantomograms manually. Deep learning models are the current state-of-the-art in automated dental age estimation applications. When applying deep learning models to high-stakes scenarios, such as forensic investigations, understanding the model’s behaviour is critical. In this context, we investigate a scenario where the automated staging of tooth 37 and tooth 38, the left second and third mandibular molars, with a vision transformer (ViT) model displays a striking performance disparity, achieving accuracies of 0.64 and 0.37, respectively. We further explore the self-attention mechanism of the ViT in search of the reason for this disparity. Furthermore, to introduce additional transparency, we propose a pipeline consisting of a convolutional autoencoder (AE) trained with triplet loss, and a ViT model for classification. This pipeline achieves accuracies of 0.72 and 0.39 on teeth 37 and 38. We further explore the latent space, image reconstructions and attention maps, contrasting the two teeth in order to uncover the reason for the poor performance on tooth 38. Through probing our pipeline, we reveal the problem of high intra-class variation in the tooth 38 dataset, and demonstrate an approach that can offer increased transparency in deep learning applications on medical image data.
- 26 May 2025
- Published by Springer Nature in Research Square
Open AccessDifferences in Automated Staging of Second and Third Molars: An Autoencoder and Vision Transformer-based Interpretability Analysis
Dental age estimation is a critical part of forensic odontology applications. It is conventionally carried out by experts on dental orthopantomograms manually. Deep learning models are the current state-of-the-art in automated dental age estimation applications. When applying deep learning models to high-stakes scenarios, such as forensic investigations, understanding the model’s behaviour is critical. In this context, we investigate a scenario where the automated staging of tooth 37 and tooth 38, the left second and third mandibular molars, with a vision transformer (ViT) model displays a striking performance disparity, achieving accuracies of 0.64 and 0.37, respectively. We further explore the self-attention mechanism of the ViT in search of the reason for this disparity. Furthermore, to introduce additional transparency, we propose a pipeline consisting of a convolutional autoencoder (AE) trained with triplet loss, and a ViT model for classification. This pipeline achieves accuracies of 0.72 and 0.39 on teeth 37 and 38. We further explore the latent space, image reconstructions and attention maps, contrasting the two teeth in order to uncover the reason for the poor performance on tooth 38. Through probing our pipeline, we reveal the problem of high intra-class variation in the tooth 38 dataset, and demonstrate an approach that can offer increased transparency in deep learning applications on medical image data.
- 6 August 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2469-2479
Artificial intelligence and dental age estimation: development and validation of an automated stage allocation technique on all mandibular tooth types in panoramic radiographs
Age estimation in forensic odontology is mainly based on the development of permanent teeth. To register the developmental status of an examined tooth, staging techniques were developed. However, due to inappropriate calibration, uncertainties during stage allocation, and lack of experience, non-uniformity in stage allocation exists between expert observers. As a consequence, related age estimation results are inconsistent. An automated staging technique applicable to all tooth types can overcome this drawback. This study aimed to establish an integrated automated technique to stage the development of all mandibular tooth types and to compare their staging performances. Calibrated observers staged FDI teeth 31, 33, 34, 37 and 38 according to a ten-stage modified Demirjian staging technique. According to a standardised bounding box around each examined tooth, the retrospectively collected panoramic radiographs were cropped using Photoshop CC 2021® software (Adobe®, version 23.0). A gold standard set of 1639 radiographs were selected (n31 = 259, n33 = 282, n34 = 308, n37 = 390, n38 = 400) and input into a convolutional neural network (CNN) trained for optimal staging accuracy. The performance evaluation of the network was conducted in a five-fold cross-validation scheme. In each fold, the entire dataset was split into a training and a test set in a non-overlapping fashion between the folds (i.e., 80% and 20% of the dataset, respectively). Staging performances were calculated per tooth type and overall (accuracy, mean absolute difference, linearly weighted Cohen’s Kappa and intra-class correlation coefficient). Overall, these metrics equalled 0.53, 0.71, 0.71, and 0.89, respectively. All staging performance indices were best for 37 and worst for 31. The highest number of misclassified stages were associated to adjacent stages. Most misclassifications were observed in all available stages of 31. Our findings suggest that the developmental status of mandibular molars can be taken into account in an automated approach for age estimation, while taking incisors into account may hinder age estimation.
- 6 August 2024
- Published by Springer Nature in International journal of legal medicine
- Vol. 138 (6) , 2469-2479
Artificial intelligence and dental age estimation: development and validation of an automated stage allocation technique on all mandibular tooth types in panoramic radiographs
Age estimation in forensic odontology is mainly based on the development of permanent teeth. To register the developmental status of an examined tooth, staging techniques were developed. However, due to inappropriate calibration, uncertainties during stage allocation, and lack of experience, non-uniformity in stage allocation exists between expert observers. As a consequence, related age estimation results are inconsistent. An automated staging technique applicable to all tooth types can overcome this drawback. This study aimed to establish an integrated automated technique to stage the development of all mandibular tooth types and to compare their staging performances. Calibrated observers staged FDI teeth 31, 33, 34, 37 and 38 according to a ten-stage modified Demirjian staging technique. According to a standardised bounding box around each examined tooth, the retrospectively collected panoramic radiographs were cropped using Photoshop CC 2021® software (Adobe®, version 23.0). A gold standard set of 1639 radiographs were selected (n31 = 259, n33 = 282, n34 = 308, n37 = 390, n38 = 400) and input into a convolutional neural network (CNN) trained for optimal staging accuracy. The performance evaluation of the network was conducted in a five-fold cross-validation scheme. In each fold, the entire dataset was split into a training and a test set in a non-overlapping fashion between the folds (i.e., 80% and 20% of the dataset, respectively). Staging performances were calculated per tooth type and overall (accuracy, mean absolute difference, linearly weighted Cohen’s Kappa and intra-class correlation coefficient). Overall, these metrics equalled 0.53, 0.71, 0.71, and 0.89, respectively. All staging performance indices were best for 37 and worst for 31. The highest number of misclassified stages were associated to adjacent stages. Most misclassifications were observed in all available stages of 31. Our findings suggest that the developmental status of mandibular molars can be taken into account in an automated approach for age estimation, while taking incisors into account may hinder age estimation.
- 30 January 2024
- Published by Wiley in Journal of Forensic Sciences
- Vol. 69 (3) , 919-931
OPG‐based dental age estimation using a data‐technical exploration of deep learning techniques
Dental age estimation, a cornerstone in forensic age assessment, has been extensively tried and tested, yet manual methods are impeded by tedium and interobserver variability. Automated approaches using deep transfer learning encounter challenges like data scarcity, suboptimal training, and fine‐tuning complexities, necessitating robust training methods. This study explores the impact of convolutional neural network hyperparameters, model complexity, training batch size, and sample quantity on age estimation. EfficientNet‐B4, DenseNet‐201, and MobileNet V3 models underwent cross‐validation on a dataset of 3896 orthopantomograms (OPGs) with batch sizes escalating from 10 to 160 in a doubling progression, as well as random subsets of this training dataset. Results demonstrate the EfficientNet‐B4 model, trained on the complete dataset with a batch size of 160, as the top performer with a mean absolute error of 0.562 years on the test set, notably surpassing the MAE of 1.01 at a batch size of 10. Increasing batch size consistently improved performance for EfficientNet‐B4 and DenseNet‐201, whereas MobileNet V3 performance peaked at batch size 40. Similar trends emerged in training with reduced sample sizes, though they were outperformed by the complete models. This underscores the critical role of hyperparameter optimization in adopting deep learning for age estimation from complete OPGs. The findings not only highlight the nuanced interplay of hyperparameters and performance but also underscore the potential for accurate age estimation models through optimization. This study contributes to advancing the application of deep learning in forensic age estimation, emphasizing the significance of tailored training methodologies for optimal outcomes.
- 30 January 2024
- Published by Wiley in Journal of Forensic Sciences
- Vol. 69 (3) , 919-931
OPG‐based dental age estimation using a data‐technical exploration of deep learning techniques
Dental age estimation, a cornerstone in forensic age assessment, has been extensively tried and tested, yet manual methods are impeded by tedium and interobserver variability. Automated approaches using deep transfer learning encounter challenges like data scarcity, suboptimal training, and fine‐tuning complexities, necessitating robust training methods. This study explores the impact of convolutional neural network hyperparameters, model complexity, training batch size, and sample quantity on age estimation. EfficientNet‐B4, DenseNet‐201, and MobileNet V3 models underwent cross‐validation on a dataset of 3896 orthopantomograms (OPGs) with batch sizes escalating from 10 to 160 in a doubling progression, as well as random subsets of this training dataset. Results demonstrate the EfficientNet‐B4 model, trained on the complete dataset with a batch size of 160, as the top performer with a mean absolute error of 0.562 years on the test set, notably surpassing the MAE of 1.01 at a batch size of 10. Increasing batch size consistently improved performance for EfficientNet‐B4 and DenseNet‐201, whereas MobileNet V3 performance peaked at batch size 40. Similar trends emerged in training with reduced sample sizes, though they were outperformed by the complete models. This underscores the critical role of hyperparameter optimization in adopting deep learning for age estimation from complete OPGs. The findings not only highlight the nuanced interplay of hyperparameters and performance but also underscore the potential for accurate age estimation models through optimization. This study contributes to advancing the application of deep learning in forensic age estimation, emphasizing the significance of tailored training methodologies for optimal outcomes.