NLNick-Sidney Lemberger

Nick-Sidney Lemberger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nick-Sidney Lemberger has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enabling 3D refractive index tomography in laser scanning microscopy with a simple tape-on detector

    by Nick S. Lemberger, Carsten Fallnich

    We introduce quantitative scanned oblique back-illumination microscopy (qsOBM) for laser scanning microscopes (LSMs), enabling quantitative three-dimensional refractive index (RI) tomography in thick scattering samples. By exploiting the reciprocity of light scattering, the established camera-based qOBM reconstruction framework is extended to a scanning implementation. Experimentally, qsOBM is realized with a slide-mounted four-quadrant photodetector requiring only minimal optomechanical modification of a conventional LSM. We demonstrate quantitative RI imaging and multimodal qsOBM/epi-detected second-harmonic generation (SHG) microscopy of type I collagen and adipose tissue in chicken muscle. The resulting RI tomograms provide label-free volumetric morphological information that complements SHG microscopy and expands the capabilities of existing LSM platforms for multimodal tissue imaging.

  • Open Access

    Automated correction of optical attenuation in stimulated Raman scattering imaging

    by Nick S. Lemberger, Kristin Wallmeier, Carsten Fallnich

    Transmission losses in stimulated Raman scattering (SRS) microscopy degrade quantitative chemical imaging by introducing artifacts. We present a real-time correction scheme based on active electronic gain control to independently compensate for pump and Stokes transmission losses. In addition to correcting Stokes losses in transmission mode, our method uses the pump light that is backscattered from the focal volume to measure the pump transmission factors affecting the SRS process and exploits the logarithmic gain interface of a variable gain amplifier to implement the required square root operation for compensation. Validation experiments on both homogeneous and heterogeneous samples demonstrated a chemically specific contrast that is almost independent of transmission losses, leading to a significant improvement in image uniformity and representing a step towards quantitative SRS imaging.

  • Adaptive optics stimulated Raman scattering microscopy for topical product pharmacokinetic imaging

    by Saara K. Luna, Benjamin A. Kuzma, Nick-Sidney Lemberger, Kristin Wallmeier, Carsten Fallnich, Conor L. Evans

    Topically applied drug products are used to treat various dermatological conditions, enabling local and targeted delivery of active pharmaceutical ingredients. To ensure appropriate topical drug efficacy and delivery, it is necessary to understand the pharmacokinetics of topical drug uptake. Stimulated Raman scattering (SRS) microscopy, a chemically specific imaging modality, is well-suited to quantitatively measure the spatiotemporal kinetics of topical drug permeation in skin. However, SRS imaging depth in skin is often limited due to skin heterogeneity and scattering effects, distorting the laser focus and reducing the SRS signal. Adaptive optics (AO) can help overcome and correct depth limitations by adjusting wavefront shape and improving laser focus with a programmable optical element, such as a deformable membrane mirror. Previous work has demonstrated the use of AO in optimizing coherent anti-Stokes Raman scattering (CARS) signal in tissue imaging. In this study, we evaluated the ability of AO to improve the SRS signal in tissue imaging using a deformable membrane mirror as the AO element, which utilized a simulated annealing algorithm to search for mirror shapes producing optimal SRS signal at different tissue imaging depths. AO SRS images had an 11% increase in SRS signal intensity and >350% increase in image contrast between high and low signal regions compared to non-AO SRS images in nude mouse ear skin at the same depth. Mirror shapes optimized at greater imaging depths produced increased SRS intensity and contrast for a range of imaging depths (up to 290 μ m in chicken muscle). Using AO SRS, we performed time-lapse imaging of ruxolitinib uptake in ex vivo human skin, demonstrating that AO SRS can be used to quantitatively measure topical drug pharmacokinetics in deeper skin structures (>100 μ m).


  • Open Access

    Improved Dual-Modality Bioequivalence Evaluation of Topical Formulations Within Human Skin Using Stimulated Raman Scattering Microscopy

    by Dandan Tu, Nick-Sidney Lemberger, Kristin Wallmeier, Jackson Riseman, Benjamin A. Kuzma, Yuxiao Wei, Ting Chean Khoo, Elena Rantou, Priyanka Ghosh, Markham C. Luke, et al.

    Background: The use of optical microscopic techniques has gained increasing attention in recent years for studying the bioavailability (BA) and bioequivalence (BE) of topical drugs. Stimulated Raman scattering (SRS), one type of optical imaging technique, probes chemical-specific information and has excellent spatiotemporal resolution. It uses intrinsic molecular vibrational signatures, and therefore, labeling samples or other treatments is unnecessary to track a molecule. Because of its unique advantages, studies have used SRS for BA evaluations and, more recently, for BE evaluations. In BE evaluation, low data variance within a treatment group is important to ensure sensitivity and specificity in comparing treatment groups. Methods: When measuring forward-direction SRS signals transmitted through skin, the signal intensity is susceptible to variance due to several factors, such as the microscope system’s performance, the different optical features of topical drug products, and the heterogeneity of skin in transmitting light. This work closely investigated the effects of these factors on an SRS signal and developed solutions to reduce their effects on the data variance. Specifically, we constructed a method using a dual-modality detector built in-house, which simultaneously measured both the SRS signal and total light transmission synchronized in time and co-registered in space. Results: We developed equations to normalize SRS signals using the transmission intensity, and the results demonstrated a clear improvement in the SRS signal via a reduction in the signal variance (up to a 9.46% CV value decrease) that is otherwise caused by various factors associated with the use of topical drugs and the composition of the skin. We carried out an exploratory BE study using tretinoin-containing topical products and observed improvements in BE assessment with the developed method (could achieve a reduction of 0.11 in the CI value). Conclusions: This work has led to a better understanding of the factors that affect SRS imaging and has provided an effective method to compensate for these factors in BE assessments. This is a critical initial effort for better practical implementation of SRS in cutaneous pharmacokinetics (cPKs) studies of topical drugs.