Edmond Baratte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Edmond Baratte has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Olivier Guaitella
LPP, CNRS, École Polytechnique, Sorbonne Université, Université Paris-Saclay, IP-Paris 91128 Palaiseau, France
4 shared publications - Tiago Silva
Universidade de Lisboa
3 shared publications - Dihya Sadi
Université Paris-Saclay
2 shared publications - Jean-Paul Booth
LPP, CNRS, École Polytechnique, Sorbonne Université, Université Paris-Saclay, IP-Paris 91128 Palaiseau, France
2 shared publications - Lex Kuijpers
Department of Applied Physics, Eindhoven Institute for Renewable Energy Systems, Eindhoven University of Technology, Eindhoven, The Netherlands
2 shared publications - Mauritius van de Sanden
Dutch Institute for Fundamental Energy Research
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (9) , 095005
Ro-vibrational temperatures of CO( X ) deduced from emission of third positive and Angström system of CO in CO 2 glow discharges
Optical emission spectroscopy (OES) offers a flexible diagnostic for plasma sources where conventional techniques such as infrared absorption or Raman spectroscopy are difficult to implement in situ . However, the quantitative interpretation of emission spectra remains challenging, which often limits the use of OES. In this work, we investigate the possibility of using OES to determine the rotational and vibrational excitation of CO in CO 2 glow discharges. Experiments were carried out in CO 2 DC glow discharges at 7.4 sccm flows and pressures between 1 and 5 Torr and currents between 10 and 50 mA. The analysis is based on emission from two electronic systems of CO: the Third Positive System, CO( b 3 Σ + → a 3 Π ), and the Angström system, CO( B 1 Σ + → A 1 Π ) covering respectively the 300–400 nm and 350–600 nm regions. A methodology is developed to extract rotational and vibrational temperatures from the measured spectra and to relate the emitting-state vibrational populations to the ground-state distribution using Franck–Condon factors. The results obtained from OES are systematically compared with in situ infrared absorption spectroscopy measurements performed under the same plasma conditions using Fourier Transform Infrared spectroscopy. This comparison enables the validation of the spectroscopic constants used in the simulations and provides an estimate of the accuracy of the proposed approach and the identification of crucial fundamental processes for careful treatment and interpretation. The methodology allows for the determination of CO rotational and vibrational temperatures with an accuracy of approximately 100 K. These results demonstrate that, when combined with appropriate spectral modeling, OES can provide quantitative information on excitation in CO 2 plasmas using compact and flexible spectrometers with an error of a maximum of 10% over the investigated experimental conditions.
- 1 September 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (9) , 095005
Open AccessRo-vibrational temperatures of CO( X ) deduced from emission of third positive and Angström system of CO in CO 2 glow discharges
Optical emission spectroscopy (OES) offers a flexible diagnostic for plasma sources where conventional techniques such as infrared absorption or Raman spectroscopy are difficult to implement in situ . However, the quantitative interpretation of emission spectra remains challenging, which often limits the use of OES. In this work, we investigate the possibility of using OES to determine the rotational and vibrational excitation of CO in CO 2 glow discharges. Experiments were carried out in CO 2 DC glow discharges at 7.4 sccm flows and pressures between 1 and 5 Torr and currents between 10 and 50 mA. The analysis is based on emission from two electronic systems of CO: the Third Positive System, CO( b 3 Σ + → a 3 Π ), and the Angström system, CO( B 1 Σ + → A 1 Π ) covering respectively the 300–400 nm and 350–600 nm regions. A methodology is developed to extract rotational and vibrational temperatures from the measured spectra and to relate the emitting-state vibrational populations to the ground-state distribution using Franck–Condon factors. The results obtained from OES are systematically compared with in situ infrared absorption spectroscopy measurements performed under the same plasma conditions using Fourier Transform Infrared spectroscopy. This comparison enables the validation of the spectroscopic constants used in the simulations and provides an estimate of the accuracy of the proposed approach and the identification of crucial fundamental processes for careful treatment and interpretation. The methodology allows for the determination of CO rotational and vibrational temperatures with an accuracy of approximately 100 K. These results demonstrate that, when combined with appropriate spectral modeling, OES can provide quantitative information on excitation in CO 2 plasmas using compact and flexible spectrometers with an error of a maximum of 10% over the investigated experimental conditions.
- Top Cited PapersOpen Access
- 1 January 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (1) , 015009
Determination of the accuracy of actinometry and line ratio techniques in an O 2 glow discharge: I. Comparison of absolute oxygen atom densities with CRDS measurements
The accuracy of oxygen atom density measurements in plasmas by optical emission actinometry was tested by comparison to simultaneous direct absorption measurements on the 1 D 2 ← 3 P 2 transition by cavity ringdown spectroscopy (CRDS). The accuracy of the latter technique depends only on the accuracy to which the transition probability is known. Measurements were performed on a glow discharge in O 2 operating between 0.5 and 5 Torr, and using both Ar and Xe as the actinometer gas. The rate constants for electron impact excitation, and thus the actinometry calibration factors, were calculated from the (measured) reduced electric field using a Boltzmann equation solver (Loki-B). Several sets of cross-section were tested for the EEDF calculation and for the electron impact excitation to the specific levels of O, Ar and Xe used for actinometry. The best results were obtained with the IST Lisbon cross-section set for O 2 and O, and the BSR500 excitation cross-sections for Ar and Xe. Good agreement with the CRDS trends and absolute values was observed when using Xe as the actinometer gas, whereas with Ar the trends were well reproduced but it was necessary to increase the electron impact cross-section of the transition Ar( 1 S 0 → 2 p 1 ) of the BSR500 database by a factor of 3±0.3 to reproduce the absolute values.
- 1 January 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (1) , 015009
Top Cited PapersOpen AccessDetermination of the accuracy of actinometry and line ratio techniques in an O 2 glow discharge: I. Comparison of absolute oxygen atom densities with CRDS measurements
The accuracy of oxygen atom density measurements in plasmas by optical emission actinometry was tested by comparison to simultaneous direct absorption measurements on the 1 D 2 ← 3 P 2 transition by cavity ringdown spectroscopy (CRDS). The accuracy of the latter technique depends only on the accuracy to which the transition probability is known. Measurements were performed on a glow discharge in O 2 operating between 0.5 and 5 Torr, and using both Ar and Xe as the actinometer gas. The rate constants for electron impact excitation, and thus the actinometry calibration factors, were calculated from the (measured) reduced electric field using a Boltzmann equation solver (Loki-B). Several sets of cross-section were tested for the EEDF calculation and for the electron impact excitation to the specific levels of O, Ar and Xe used for actinometry. The best results were obtained with the IST Lisbon cross-section set for O 2 and O, and the BSR500 excitation cross-sections for Ar and Xe. Good agreement with the CRDS trends and absolute values was observed when using Xe as the actinometer gas, whereas with Ar the trends were well reproduced but it was necessary to increase the electron impact cross-section of the transition Ar( 1 S 0 → 2 p 1 ) of the BSR500 database by a factor of 3±0.3 to reproduce the absolute values.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (1) , 015010
Determination of the accuracy of actinometry and line ratio techniques in an O 2 glow discharge: II. Electric field measurements with Ar and Xe admixtures *
A line-ratio method for determining the reduced electric field is benchmarked against independent measurements from electrostatic probes and cavity ring-down spectroscopy. The method is applied to oxygen DC glow discharges with trace admixtures of argon and xenon. A corona model incorporating fluorescence quenching by heavy species is used to simulate the emission, with electron-impact excitation rates calculated using the LisbOn KInetics Boltzmann solver. The excitation cross sections and quenching coefficients are those proposed and validated for actinometry in part one of this combined study (Baratte et al 2025 Plasma Sources Sci. Technol. ). The reduced electric field is determined over a pressure range of 0.55 to 5 Torr (at 40 mA) and a current range of 15 to 50 mA (at 5 Torr). Consistent agreement with measured emission line intensities is achieved when applying a correction factor of κ c , Ar = 3 ± 0.5 to the excitation cross sections for the argon lines at 750 nm and 811 nm. With this correction, the reduced electric field values obtained from the line-ratio method are in good agreement with direct measurements. A comparison of different line ratios is presented, showing that the best performance is achieved using the ratio of the Ar 750 nm and Xe 828 nm lines. This ratio is particularly sensitive to changes in the electron energy distribution function, due to the large difference in excitation thresholds, while remaining independent of the knowledge of species densities.
- 1 January 2026
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 35 (1) , 015010
Open AccessDetermination of the accuracy of actinometry and line ratio techniques in an O 2 glow discharge: II. Electric field measurements with Ar and Xe admixtures *
A line-ratio method for determining the reduced electric field is benchmarked against independent measurements from electrostatic probes and cavity ring-down spectroscopy. The method is applied to oxygen DC glow discharges with trace admixtures of argon and xenon. A corona model incorporating fluorescence quenching by heavy species is used to simulate the emission, with electron-impact excitation rates calculated using the LisbOn KInetics Boltzmann solver. The excitation cross sections and quenching coefficients are those proposed and validated for actinometry in part one of this combined study (Baratte et al 2025 Plasma Sources Sci. Technol. ). The reduced electric field is determined over a pressure range of 0.55 to 5 Torr (at 40 mA) and a current range of 15 to 50 mA (at 5 Torr). Consistent agreement with measured emission line intensities is achieved when applying a correction factor of κ c , Ar = 3 ± 0.5 to the excitation cross sections for the argon lines at 750 nm and 811 nm. With this correction, the reduced electric field values obtained from the line-ratio method are in good agreement with direct measurements. A comparison of different line ratios is presented, showing that the best performance is achieved using the ratio of the Ar 750 nm and Xe 828 nm lines. This ratio is particularly sensitive to changes in the electron energy distribution function, due to the large difference in excitation thresholds, while remaining independent of the knowledge of species densities.