Ruixu Geng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ruixu Geng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Binbin Zhang
School of Cyber Science and Technology University of Science and Technology of China 230026 Hefei China
1 shared publicationBinquan Wang
School of Cyber Science and Technology University of Science and Technology of China 230026 Hefei China
1 shared publication- Dongheng Zhang
University of Science and Technology of China
1 shared publication Pengcheng Huang
School of Cyber Science and Technology University of Science and Technology of China 230026 Hefei China
1 shared publication- Yadong Li
School of Cyber Science and Technology University of Science and Technology of China 230026 Hefei China
1 shared publication - Yan Chen
University of Science and Technology of China
1 shared publication
Latest Publications
- Open Access
Automatic Phase Calibration for High-resolution mmWave Sensing via Ambient Radio Anchors
Millimeter-wave (mmWave) radar systems with large array have pushed radar sensing into a new era, thanks to their high angular resolution. However, our long-term experiments indicate that array elements exhibit phase drift over time and require periodic phase calibration to maintain high-resolution, creating an obstacle for practical high-resolution mmWave sensing. Unfortunately, existing calibration methods are inadequate for periodic recalibration, either because they rely on artificial references or fail to provide sufficient precision. To address this challenge, we introduce AutoCalib, the first framework designed to automatically and accurately calibrate high-resolution mmWave radars by identifying Ambient Radio Anchors (ARAs)-naturally existing objects in ambient environments that offer stable phase references. AutoCalib achieves calibration by first generating spatial spectrum templates based on theoretical electromagnetic characteristics. It then employs a pattern-matching and scoring mechanism to accurately detect these anchors and select the optimal one for calibration. Extensive experiments across 11 environments demonstrate that AutoCalib capable of identifying ARAs that existing methods miss due to their focus on strong reflectors. AutoCalib's calibration performance approaches corner reflectors (74% phase error reduction) while outperforming existing methods by 83%. Beyond radar calibration, AutoCalib effectively supports other phase-dependent applications like handheld imaging, delivering 96% of corner reflector calibration performance without artificial references.
Open AccessAutomatic Phase Calibration for High-resolution mmWave Sensing via Ambient Radio Anchors
Millimeter-wave (mmWave) radar systems with large array have pushed radar sensing into a new era, thanks to their high angular resolution. However, our long-term experiments indicate that array elements exhibit phase drift over time and require periodic phase calibration to maintain high-resolution, creating an obstacle for practical high-resolution mmWave sensing. Unfortunately, existing calibration methods are inadequate for periodic recalibration, either because they rely on artificial references or fail to provide sufficient precision. To address this challenge, we introduce AutoCalib, the first framework designed to automatically and accurately calibrate high-resolution mmWave radars by identifying Ambient Radio Anchors (ARAs)-naturally existing objects in ambient environments that offer stable phase references. AutoCalib achieves calibration by first generating spatial spectrum templates based on theoretical electromagnetic characteristics. It then employs a pattern-matching and scoring mechanism to accurately detect these anchors and select the optimal one for calibration. Extensive experiments across 11 environments demonstrate that AutoCalib capable of identifying ARAs that existing methods miss due to their focus on strong reflectors. AutoCalib's calibration performance approaches corner reflectors (74% phase error reduction) while outperforming existing methods by 83%. Beyond radar calibration, AutoCalib effectively supports other phase-dependent applications like handheld imaging, delivering 96% of corner reflector calibration performance without artificial references.