HLHenny A. B. Lesnussa

Henny A. B. Lesnussa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Henny A. B. Lesnussa has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Analysis of Electrical Energy Savings Opportunities and Energy Conservation for Social Sector Customers in Manokwari Regency

    by Henny A. B. Lesnussa, Abdul Z Patiran, Yulianus R Pasalli

    The rapid growth of the population and socio-economic activities in society has led to anincreasing demand for and consumption of electrical energy every year. Customers in the social sector,specifically those under tariff categories S1, S2, and S3, such as office buildings, schools, universities,hospitals, and other buildings, are believed to be the largest consumers of electrical energy, given the highlevel of activity in this sector. This has prompted efforts to conserve energy, in line with GovernmentRegulation No. 70/2009 on Energy Conservation. To achieve this, the initial step involves conducting anenergy audit, a method used to calculate the energy consumption rate of a building. The purpose of thisstudy is to analyze energy consumption and energy conservation programs for social sector customers inManokwari Regency. The analysis results show that the Energy Consumption Intensity (IKE) for electricityuse among social sector customers in Manokwari is 64,5 kWh/m²/month, with an average IKE of 10,67kWh/m²/month, which is considered efficient for air-conditioned rooms according to the Ministry of Energyand Mineral Resources Regulation No. 13 of 2012. and then the recommended energy savings opportunityis 44,3%, equivalent to 12.279,18 kWh/month.

  • Open Access

    Analisa Kelayakan Taxiway Light (Studi Kasus Bandara Rendani Manokwari)

    by Raja H. Tampubolon, Henny A. B. Lesnussa, Abdul Z. Patiran

    Taxiway Light is a road that connects between the apron and the runway. Its existence is very important because with the taxiway light, the aircraft can go to an apron safely without disturbing other aircraft. CCR or Constant Current Regulator as a component, its functions to regulates a current fixed and constant in taxiway light with the lighting level divided into five levels, namely step 1 to step 5. The electrical system on the taxiway light is assembled and installed in series with the intention that if one of the circuits is extinguished, the other system is still running. The electrical system on the taxiway light uses the CCR components to produce a constant current. This research used the case study method. The existing load data on step1 is 3,727 Watts, step 2 is 4,495 Watts, step 3 is 5,450 Watts, step 4 is 6,896 Watts, step 5 is 8,723 Watts and step 1for load calculation data is 3,527 Watts, step 2 is 4,488 Watts, step 3 is 5,438 Watts, step 4 is 6,864 Watts, step 5 is 8,712 Watts which means that the results of the comparison at Rendani Airport are feasible because the existing load data is greater than the load data of the calculation results.