Haydar Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haydar Hassan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Abdulraheem Kadhim AbidAli
Department of Metallurgical, College of Materials Engineering, University of Babylon, Babylon, Iraq
1 shared publication Ahmed Ouda
Metallurgical Engineering, Materials Engineering College, University of Babylon
1 shared publication- Anasalwjood A. Mahmoud
Department of metal, college of materials Engineering, University of Babylon, Babylon, Iraq
1 shared publication Jamal Al-Deen
Department of metal, college of materials Engineering, University of Babylon, Babylon, Iraq
1 shared publicationMalik Abdul-Husien
Metallurgical Engineering, Materials Engineering College, University of Babylon; Technical Institute of Babylon, Al-Furat Al-Awsat Technical University (ATU), Iraq
1 shared publication
Latest Publications
- Open Access
- 15 June 2025
- Published by Engineering Society of Corrosion in Zastita materijala
- Vol. 66 (2) , 421-428
Effect of (Ge) addition on mechanical properties of (Ti12Mo5Ta) alloy used in biomedical applications
The primary objective of this investigation is to examine the impact of adding (Ge) to the Ti12Mo5Ta alloy on its compressive strength, hardness, and elastic modulus. A Ti-Mo-Ta alloy with an 83% Ti, 12% Mo, and 5% Ta composition was synthesized by powder metallurgy, with the inclusion of Ge. The mixing procedure lasted for a duration of 5 hours, with a compacting pressure of 800MPa applied to create a disk sample. After the compaction step, the samples were sintered by gradually increasing the temperature to 950 ºC at a rate of 10 ˚C/min, which took a total of 7 hours. The addition of (Ge) is done in different weight percentages, ranging from 0.5% to 5%.The impact of (Ge) was examined using X-ray diffraction. The addition of 0.5% to 5% (Ge) enhances the compressive strength of the Ti12Mo5Ta alloy. Similarly, the macro hardness of the alloy increases with higher Ge content.Conversely the inclusion of 0.5% to 5% (Ge) causes a decrease in the elastic modulus of the Ti12Mo5Ta alloy.
- 15 June 2025
- Published by Engineering Society of Corrosion in Zastita materijala
- Vol. 66 (2) , 421-428
Open AccessEffect of (Ge) addition on mechanical properties of (Ti12Mo5Ta) alloy used in biomedical applications
The primary objective of this investigation is to examine the impact of adding (Ge) to the Ti12Mo5Ta alloy on its compressive strength, hardness, and elastic modulus. A Ti-Mo-Ta alloy with an 83% Ti, 12% Mo, and 5% Ta composition was synthesized by powder metallurgy, with the inclusion of Ge. The mixing procedure lasted for a duration of 5 hours, with a compacting pressure of 800MPa applied to create a disk sample. After the compaction step, the samples were sintered by gradually increasing the temperature to 950 ºC at a rate of 10 ˚C/min, which took a total of 7 hours. The addition of (Ge) is done in different weight percentages, ranging from 0.5% to 5%.The impact of (Ge) was examined using X-ray diffraction. The addition of 0.5% to 5% (Ge) enhances the compressive strength of the Ti12Mo5Ta alloy. Similarly, the macro hardness of the alloy increases with higher Ge content.Conversely the inclusion of 0.5% to 5% (Ge) causes a decrease in the elastic modulus of the Ti12Mo5Ta alloy.
- Open Access
- 1 August 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1973 (1) , 012146
Improved performance of Ti6Al4V alloy in Biomedical applications - Review.
The advantages of Ti6Al4v alloy are high strength, low density, and And the advantage of it being non-toxic and the human body does not reject it. Because of these properties, Ti6Al4v are distinguished by their unique properties. To manufacture high strength and lightweight components for biomedical applications, Ti6Al4v alloy is suitable for purpose because of its properties necessary for manufacture. The properties of TiAl4v alloy about its mechanical properties, its corrosion resistance, wear testing, biocompatibility, and bone fusion in biomedical applications, are discussed in the paper. Although TiAl4v alloy has desirable properties, studies have proven to release the two elements of aluminum and vanadium. These two elements are toxic and affect the biocompatibility of Ti6Al4v despite its unique properties. To avoid that, researchers are looking for a way to solve the problem by addition alloy elements that are less toxic and have good mechanical properties. Examples of these elements are zirconium and tantalum..
- 1 August 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1973 (1) , 012146
Open AccessImproved performance of Ti6Al4V alloy in Biomedical applications - Review.
The advantages of Ti6Al4v alloy are high strength, low density, and And the advantage of it being non-toxic and the human body does not reject it. Because of these properties, Ti6Al4v are distinguished by their unique properties. To manufacture high strength and lightweight components for biomedical applications, Ti6Al4v alloy is suitable for purpose because of its properties necessary for manufacture. The properties of TiAl4v alloy about its mechanical properties, its corrosion resistance, wear testing, biocompatibility, and bone fusion in biomedical applications, are discussed in the paper. Although TiAl4v alloy has desirable properties, studies have proven to release the two elements of aluminum and vanadium. These two elements are toxic and affect the biocompatibility of Ti6Al4v despite its unique properties. To avoid that, researchers are looking for a way to solve the problem by addition alloy elements that are less toxic and have good mechanical properties. Examples of these elements are zirconium and tantalum..