Asahi Sujino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Asahi Sujino has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Takeo Nagura
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
3 shared publicationsAkihito Oya
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
2 shared publicationsAkimasa Ito
2 shared publicationsAtsuhiro Fujie
Department of Orthopaedic Surgery Keio University School of Medicine Tokyo Japan
2 shared publicationsMasaya Nakamura
2 shared publications- Naomichi Ogihara
Department of Biological Sciences, Graduate School of Science, The University of Tokyo, Tokyo, Japan
2 shared publications
Latest Publications
- 24 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (11) , e70296
Acetabular Cup Fixation in Total Hip Arthroplasty Evaluated Using Laser Resonance Frequency Analysis
The initial fixation of the acetabular cup is crucial for outcomes in total hip arthroplasty (THA); however, stability is evaluated subjectively. We developed a Laser Resonance Frequency Analysis (Laser‐RFA) system using low‐output laser‐induced vibration to objectively assess fixation. This study demonstrates the relationship between fixation strength and vibrational characteristics and evaluates surgeons' tactile assessment. In laboratory experiments, acetabular cups were press‐fit into polyurethane simulated bone and stimulated with frequency‐swept laser irradiation (preliminary laboratory experiment: 1500–4500 Hz; modified‐condition: 2250–2750 Hz). Peak frequencies measured by the Laser Doppler vibrometer were correlated with fixation strength. In the clinical study, peak frequencies from microphone‐recorded vibrations were compared between cases with and without screw fixation based on intraoperative tactile assessment. In a supplemental experiment, surgeons were divided into skilled and non‐skilled groups. Participants implanted an acetabular cup into simulated bone, and tactile fixation strength was quantified. Periodic waveforms were identified in the preliminary experiment, and six peaks (Waves A–F) were defined in the modified‐condition laboratory experiment. Waves A and B showed negative correlations with fixation strength, whereas Waves C–F showed positive correlations. Clinically, peak frequencies were lower in cases requiring screw fixation than in those not requiring screw fixation (approximately 2900 vs. 3050 Hz; p < 0.003). The supplemental experiment showed significant differences in fixation strength across all tactile assessment levels in the skilled group, whereas no significant differences were observed in the non‐skilled group. These findings indicate Laser‐RFA objectively assesses acetabular cup fixation and reflects the tactile assessment of experienced surgeons.
- 24 October 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (11) , e70296
Acetabular Cup Fixation in Total Hip Arthroplasty Evaluated Using Laser Resonance Frequency Analysis
The initial fixation of the acetabular cup is crucial for outcomes in total hip arthroplasty (THA); however, stability is evaluated subjectively. We developed a Laser Resonance Frequency Analysis (Laser‐RFA) system using low‐output laser‐induced vibration to objectively assess fixation. This study demonstrates the relationship between fixation strength and vibrational characteristics and evaluates surgeons' tactile assessment. In laboratory experiments, acetabular cups were press‐fit into polyurethane simulated bone and stimulated with frequency‐swept laser irradiation (preliminary laboratory experiment: 1500–4500 Hz; modified‐condition: 2250–2750 Hz). Peak frequencies measured by the Laser Doppler vibrometer were correlated with fixation strength. In the clinical study, peak frequencies from microphone‐recorded vibrations were compared between cases with and without screw fixation based on intraoperative tactile assessment. In a supplemental experiment, surgeons were divided into skilled and non‐skilled groups. Participants implanted an acetabular cup into simulated bone, and tactile fixation strength was quantified. Periodic waveforms were identified in the preliminary experiment, and six peaks (Waves A–F) were defined in the modified‐condition laboratory experiment. Waves A and B showed negative correlations with fixation strength, whereas Waves C–F showed positive correlations. Clinically, peak frequencies were lower in cases requiring screw fixation than in those not requiring screw fixation (approximately 2900 vs. 3050 Hz; p < 0.003). The supplemental experiment showed significant differences in fixation strength across all tactile assessment levels in the skilled group, whereas no significant differences were observed in the non‐skilled group. These findings indicate Laser‐RFA objectively assesses acetabular cup fixation and reflects the tactile assessment of experienced surgeons.
- Open Access
- 7 May 2026
- Published by Elsevier in SSRN Electronic Journal
GROUND REACTION FORCE IS MORE ANTERIORLY ORIENTED AT THE HIP JOINT IN HIP OSTEOARTHRITIS PATIENTS THAN IN HEALTHY ELDERLY
BackgroundMechanical loading promotes joint deformation and is a known risk factor for hip osteoarthritis, playing a key role in understanding its pathology. However, details of the lower limb load line remain unreported. In this study, we simultaneously measured hip joint loading using upright multidetector computed tomography and a force plate to characterize hip joint loading in healthy subjects and hip osteoarthritis patients. MethodsWe measured ground reaction force and performed CT imaging on 19 healthy elderly subjects and 18 hip osteoarthritis patients in a quiet standing posture. The acquired data were combined to evaluate the ground reaction force vector. FindingsThe ground reaction force passed through the medial-posterior acetabulum in both groups but was more anterior in hip osteoarthritis. No significant differences were found in center of pressure or ground reaction force direction. The femoral head was more posteriorly positioned, and femoral bowing was greater in hip osteoarthritis than in healthy subjects. InterpretationConsistent with previous studies, the ground reaction force vector shifted anteriorly in hip osteoarthritis. A possible explanation is increased femoral bowing, which may have shifted the femoral head posteriorly, resulting in anteriorly directed loading. This study provides precise, simultaneous ground reaction force and skeletal posture measurements, suggesting the anterior ground reaction force shift is due to femoral morphological changes.
- 7 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessGROUND REACTION FORCE IS MORE ANTERIORLY ORIENTED AT THE HIP JOINT IN HIP OSTEOARTHRITIS PATIENTS THAN IN HEALTHY ELDERLY
BackgroundMechanical loading promotes joint deformation and is a known risk factor for hip osteoarthritis, playing a key role in understanding its pathology. However, details of the lower limb load line remain unreported. In this study, we simultaneously measured hip joint loading using upright multidetector computed tomography and a force plate to characterize hip joint loading in healthy subjects and hip osteoarthritis patients. MethodsWe measured ground reaction force and performed CT imaging on 19 healthy elderly subjects and 18 hip osteoarthritis patients in a quiet standing posture. The acquired data were combined to evaluate the ground reaction force vector. FindingsThe ground reaction force passed through the medial-posterior acetabulum in both groups but was more anterior in hip osteoarthritis. No significant differences were found in center of pressure or ground reaction force direction. The femoral head was more posteriorly positioned, and femoral bowing was greater in hip osteoarthritis than in healthy subjects. InterpretationConsistent with previous studies, the ground reaction force vector shifted anteriorly in hip osteoarthritis. A possible explanation is increased femoral bowing, which may have shifted the femoral head posteriorly, resulting in anteriorly directed loading. This study provides precise, simultaneous ground reaction force and skeletal posture measurements, suggesting the anterior ground reaction force shift is due to femoral morphological changes.
- 8 September 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (10) , 1193-1202
Kinematic and Kinetic Effects of 10-Degree Coronal Wedge Floors on Lower Limb Joints During Static Standing: An Upright Multidetector-Row CT Study
Background: Coronal wedge insoles are commonly prescribed to mitigate musculoskeletal disorders, yet their static-standing kinematic and kinetic effects on lower extremity joints remain insufficiently understood. Methods: This cross-sectional experimental study included 15 healthy older adults (mean 64.9 ± 6.0 y; 11 females, 4 males) who underwent CT imaging of the entire lower limbs during static standing. Ground reaction forces (GRFs) were simultaneously recorded using right and left force plates, with their sum equal in magnitude and opposite in direction to the body weight vector. Three floor conditions were tested: a 10-degree medial wedge, a flat surface, and a 10-degree lateral wedge. Lower limb alignment, GRF vector inclinations, projected GRF location at the height of the joint center, and external joint moments were assessed under 3 floor conditions. Results: Coronal wedges altered hip and subtalar joint angles, with medial wedges inducing hindfoot supination and hip abduction, whereas lateral wedges promoted hindfoot pronation and hip internal rotation. The GRF vector was found to generally pass lateral to the tibiotalar and subtalar joints and medial to the hip joint, generating eversion and adduction moments, respectively. Notably, these moments increased on the lateral wedge but were reduced on the medial wedge. In contrast, projected GRF location at joint height remained near the knee joint center across all conditions, resulting in minimal varus/valgus knee moments. Conclusion: This study provides the first quantifications of the 3-dimensional GRF vector concerning joint centers during static standing; these exploratory findings warrant confirmation during gait and in symptomatic cohorts. Our study suggests that lateral wedges tend to increase external joint moments at the hip and tibiotalar. Although further investigation is needed, these mechanical effects at the hip may have potential relevance and should be considered with caution when prescribing lateral wedge insoles.
- 8 September 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (10) , 1193-1202
Kinematic and Kinetic Effects of 10-Degree Coronal Wedge Floors on Lower Limb Joints During Static Standing: An Upright Multidetector-Row CT Study
Background: Coronal wedge insoles are commonly prescribed to mitigate musculoskeletal disorders, yet their static-standing kinematic and kinetic effects on lower extremity joints remain insufficiently understood. Methods: This cross-sectional experimental study included 15 healthy older adults (mean 64.9 ± 6.0 y; 11 females, 4 males) who underwent CT imaging of the entire lower limbs during static standing. Ground reaction forces (GRFs) were simultaneously recorded using right and left force plates, with their sum equal in magnitude and opposite in direction to the body weight vector. Three floor conditions were tested: a 10-degree medial wedge, a flat surface, and a 10-degree lateral wedge. Lower limb alignment, GRF vector inclinations, projected GRF location at the height of the joint center, and external joint moments were assessed under 3 floor conditions. Results: Coronal wedges altered hip and subtalar joint angles, with medial wedges inducing hindfoot supination and hip abduction, whereas lateral wedges promoted hindfoot pronation and hip internal rotation. The GRF vector was found to generally pass lateral to the tibiotalar and subtalar joints and medial to the hip joint, generating eversion and adduction moments, respectively. Notably, these moments increased on the lateral wedge but were reduced on the medial wedge. In contrast, projected GRF location at joint height remained near the knee joint center across all conditions, resulting in minimal varus/valgus knee moments. Conclusion: This study provides the first quantifications of the 3-dimensional GRF vector concerning joint centers during static standing; these exploratory findings warrant confirmation during gait and in symptomatic cohorts. Our study suggests that lateral wedges tend to increase external joint moments at the hip and tibiotalar. Although further investigation is needed, these mechanical effects at the hip may have potential relevance and should be considered with caution when prescribing lateral wedge insoles.