MDMayer B. Davidson

Mayer B. Davidson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mayer B. Davidson has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ImmunoDip®: An Improved Screening Method for Microalbuminuria

    by Mayer B. Davidson, Mohsen Bazargan, George Bakris, Anne Peters Harmel, Vito Campese, Emad Basta

    Background: It is important to test for microalbuminuria in patients with diabetes, hypertension and possible insulin resistance syndrome. Current screening methods are suboptimal. This study evaluates a new office screening test for microalbuminuria that utilizes a monoclonal antibody against human serum albumin (ImmunoDip®). Methods: 182 urine samples were collected from patients attending diabetes, nephrology or hypertension clinics. The ImmunoDip® screening test was carried out in the 182 samples after which albumin and creatinine concentrations were measured quantitatively in a reference laboratory. Results: Screening the 182 patient samples with ImmunoDip® and designating an albumin:creatinine ratio of ≧30 µg/mg as positive yielded a sensitivity of 96%, a specificity of 80%, a positive predictive value (PPV) of 66% and a negative predictive value (NPV) of 98%. The reduced specificity and PPV were not due to an intrinsic inaccuracy with ImmunoDip® screening of these samples, but rather was shown to be due to the discordance between the accepted upper limits of normal for the albumin:creatinine ratio (30 µg/mg) and the albumin concentration (20 mg/l), the latter corresponding to a ratio of 20 µg/mg. In 35 samples with albumin concentrations of 20–50 mg/l, ImmunoDip® screening yielded only one false negative (FN) result. Conclusions: ImmunoDip® is an excellent screening tool for microalbuminuria.


  • Revisiting the oral glucose tolerance test criterion for the diagnosis of diabetes

    by Mayer B. Davidson, David L. Schriger, Anne L. Peters, Brett Lorber

    OBJECTIVE: The Expert Committee on the Diagnosis and Classification of Diabetes retained the 2-hour glucose concentration on an oral glucose tolerance test of ≥11.1 mmol/L (200 mg/dL) as a criterion to diagnose diabetes. Since glycated hemoglobin levels have emerged as the best measure of long-term glycemia and an important predictor of microvascular and neuropathic complications, we evaluated the distribution of hemoglobin A1C (Hb A1C) levels in individuals who had undergone an oral glucose tolerance test to determine how well 2-hour values could identify those with normal versus increased Hb A1C levels. DESIGN: A cross-sectional analysis of 2 large data sets was performed. We cross-tabulated 2-hour glucose concentrations on an oral glucose tolerance test separated into 4 intervals (RESULTS: Approximately two thirds of patients in both data sets with 2-hour glucose concentrations of 11.1 to 13.3 mmol/L (200–239 mg/dL) had normal Hb A1C levels. In contrast, 60% to 80% of patients in both data sets with 2-hour glucose concentrations ≥13.3 mmol/L (240 mg/dL) had elevated Hb A1C levels. CONCLUSION: Since Hb A1C levels are the best measures presently available that reflect long-term glycemia, we conclude that the 2-hour glucose concentration criterion on an oral glucose tolerance test for the diagnosis of diabetes should be raised from ≥11.1 mmol/L (200 mg/dL) to ≥13.3 mmol/L (240 mg/dL) to remain faithful to the concept that diagnostic concentrations of glucose should predict the subsequent development of specific diabetic complications (e.g., retinopathy).