Mahmoud S. Elmahdy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud S. Elmahdy has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Abu El Ela
Structural Engineering Department, Zagazig University, Zagazig, Egypt
3 shared publications - Dušan Katunský
Institute of Architectural Engineering, Faculty of Civil Engineering, Technical University of Košice, Košice, Slovakia
3 shared publications - Tarek Nageeb Salem
Structural Engineering Department, Zagazig University, Zagazig 44519, Egypt
3 shared publications - Erika Dolníková
Institute of Architectural Engineering, Faculty of Civil Engineering, Technical University of Kosice, Vysokoskolska 4, 042 00 Kosice, Slovakia
2 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Springer Nature in International Journal of Geo-Engineering
- Vol. 17 (1) , 32
Numerical analysis of seismic performance of deep strutted excavation-structure interaction in sandy soil
- 18 September 2026
- Published by Springer Nature in International Journal of Geo-Engineering
- Vol. 17 (1) , 32
Open AccessNumerical analysis of seismic performance of deep strutted excavation-structure interaction in sandy soil
- Open Access
Numerical Investigation of Seismic Soil–Structure–Excavation Interaction in Sand
The dynamic loads affecting earth-retaining structures may increase in seismically active regions. Therefore, studying the soil–structure interaction among the soil, shoring systems, and adjacent structures is crucial. However, there is limited research on this important topic. This study investigates the seismic performance of a deep braced excavation and a nearby 10-story building in sandy soil formation. The main focus of this study is the consideration of the influence of varying foundation depths of adjacent structures on the seismic response of the shoring system and the performance of the shoring system and adjacent structure under different earthquake records. PLAXIS 2D software (Version 22.02) was used to carry out the numerical analysis. Sandy soil was modeled using the Hardening Soil with small-strain stiffness model (HS-small). Back analysis of observation data extracted from a real case study of a deep braced excavation in the central district of Kaohsiung City, adjacent to the O7 Station on the Orange Line of the Kaohsiung MRT system in Taiwan, was used to validate the numerical analysis. Beyond model validation, a parametric study was conducted to address the effect of the foundation level of the building adjacent to the excavation on both the seismic behavior of the shoring system and the structure itself, using the Loma-Prieta (1989) earthquake record. The parametric study was further extended to assess the responses of the shoring system and the adjacent structure under the influence of the earthquake records of Loma-Prieta (1989), Northridge (1994), and El-Centro (1940). The results show that the maximum lateral displacement of the diaphragm wall occurred at the top of the wall in all studied cases. The maximum dynamic bending moment in the retaining structure was more than three times the static one on average. In contrast, the dynamic shear force was more than 2.85 times the static one on average. In addition, the dynamic axial force of the first and second struts was 1.38 and 3.17 times the static forces, respectively. The results also reveal large differences in the behavior of the shoring system and the adjacent structure between the different earthquake records.
Open AccessNumerical Investigation of Seismic Soil–Structure–Excavation Interaction in Sand
The dynamic loads affecting earth-retaining structures may increase in seismically active regions. Therefore, studying the soil–structure interaction among the soil, shoring systems, and adjacent structures is crucial. However, there is limited research on this important topic. This study investigates the seismic performance of a deep braced excavation and a nearby 10-story building in sandy soil formation. The main focus of this study is the consideration of the influence of varying foundation depths of adjacent structures on the seismic response of the shoring system and the performance of the shoring system and adjacent structure under different earthquake records. PLAXIS 2D software (Version 22.02) was used to carry out the numerical analysis. Sandy soil was modeled using the Hardening Soil with small-strain stiffness model (HS-small). Back analysis of observation data extracted from a real case study of a deep braced excavation in the central district of Kaohsiung City, adjacent to the O7 Station on the Orange Line of the Kaohsiung MRT system in Taiwan, was used to validate the numerical analysis. Beyond model validation, a parametric study was conducted to address the effect of the foundation level of the building adjacent to the excavation on both the seismic behavior of the shoring system and the structure itself, using the Loma-Prieta (1989) earthquake record. The parametric study was further extended to assess the responses of the shoring system and the adjacent structure under the influence of the earthquake records of Loma-Prieta (1989), Northridge (1994), and El-Centro (1940). The results show that the maximum lateral displacement of the diaphragm wall occurred at the top of the wall in all studied cases. The maximum dynamic bending moment in the retaining structure was more than three times the static one on average. In contrast, the dynamic shear force was more than 2.85 times the static one on average. In addition, the dynamic axial force of the first and second struts was 1.38 and 3.17 times the static forces, respectively. The results also reveal large differences in the behavior of the shoring system and the adjacent structure between the different earthquake records.
- Open Access
- 15 September 2025
- Published by MDPI AG in Preprints.org
Numerical Study of Seismic- Soil-Structure-Excavation Interaction in Sand
The dynamic loads affecting earth retaining structures may increase in seismically active regions. Therefore, studying the soil-structure interaction between the soil, shoring systems, and adjacent structures is crucial. However, there is limited research on this important topic. This study analyzes the seismic performance of a deep-braced excavation and a nearby 10-story building in sandy soil formation. Sandy soil is modeled using the Hardening Soil model with small-strain stiffness (HS-small) using PLAXIS 2D software. The numerical model is validated against measured field data from a real case study of a deep-braced excavation in the central district of Kaohsiung City, adjacent to the O7 Station on the Orange Line of the Kaohsiung MRT system in Taiwan. After model validation, parametric study is conducted to investigate the impact of the foundation level of the building adjacent to the excavation on both the seismic behavior of the shoring system and the structure itself, using the Loma-Prieta (1989) earthquake record. The parametric study is further extended to assess the responses of the shoring system and the adjacent structure under the influence of the earthquake records of Loma Prieta (1989), Northridge (1994), and El Centro (1940). Analysis results show that the maximum lateral displacement of the diaphragm wall occurred at its top in all studied cases. The maximum bending moment in the retaining structure increased by more than three times of that calculated in the dynamic analysis compared to the static analysis. In contrast, the dynamic shear force is more than 2.85 times greater than the static one. In addition, the dynamic axial force in the 1st and 2nd struts increased by 1.38 and 3.17 times, respectively, compared to the static forces. Results also reveal that large differences in behavior of the shoring system and the adjacent structure are noticed between the used different earthquake records.
- 15 September 2025
- Published by MDPI AG in Preprints.org
Open AccessNumerical Study of Seismic- Soil-Structure-Excavation Interaction in Sand
The dynamic loads affecting earth retaining structures may increase in seismically active regions. Therefore, studying the soil-structure interaction between the soil, shoring systems, and adjacent structures is crucial. However, there is limited research on this important topic. This study analyzes the seismic performance of a deep-braced excavation and a nearby 10-story building in sandy soil formation. Sandy soil is modeled using the Hardening Soil model with small-strain stiffness (HS-small) using PLAXIS 2D software. The numerical model is validated against measured field data from a real case study of a deep-braced excavation in the central district of Kaohsiung City, adjacent to the O7 Station on the Orange Line of the Kaohsiung MRT system in Taiwan. After model validation, parametric study is conducted to investigate the impact of the foundation level of the building adjacent to the excavation on both the seismic behavior of the shoring system and the structure itself, using the Loma-Prieta (1989) earthquake record. The parametric study is further extended to assess the responses of the shoring system and the adjacent structure under the influence of the earthquake records of Loma Prieta (1989), Northridge (1994), and El Centro (1940). Analysis results show that the maximum lateral displacement of the diaphragm wall occurred at its top in all studied cases. The maximum bending moment in the retaining structure increased by more than three times of that calculated in the dynamic analysis compared to the static analysis. In contrast, the dynamic shear force is more than 2.85 times greater than the static one. In addition, the dynamic axial force in the 1st and 2nd struts increased by 1.38 and 3.17 times, respectively, compared to the static forces. Results also reveal that large differences in behavior of the shoring system and the adjacent structure are noticed between the used different earthquake records.