DMDavid Alexander Lemos Martínez

David Alexander Lemos Martínez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Alexander Lemos Martínez has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effectiveness of pulmonary rehabilitation in post COVID-19 patients: a systematic review and meta-analysis

    by Nathali Carvajal Tello, Alejandro Segura Ordoñez, David Alexander Lemos Martínez, Andres Fabricio Caballero Lozada, Leonardo Arzayus Patiño

    Introduction: Respiratory sequelae continue to be a prevalent problem in post-COVID-19 patients. Greater awareness among healthcare professionals regarding the effectiveness of rehabilitation could enhance its implementation. Objective: To evaluate the effects of pulmonary rehabilitation on aerobic capacity, muscle strength, functionality, quality of life, and reduction of dyspnea in post-COVID-19 patients. Methodology: It was developed in accordance with the PRISMA guidelines and registered in PROSPERO CRD42023368896. A search was conducted in four electronic databases (PubMed, Science Direct, Scopus, and Springer), with no language restrictions. Controlled clinical trials and cohort studies were selected, and their methodological quality was assessed using the PEDRO scale and the MINORS scale, respectively. The risk of bias of the controlled clinical trials included in the meta-analysis was assessed using the Cochrane Risk of Bias 2 (RoB 2.0) tool). Results: Twenty-one articles were included in the analysis, with a total of 1,761 patients aged between 39 and 71 years. Fifty-seven percent of the programs were conducted in-hospital, while 43% were offered on an outpatient basis or through telehealth. The duration of the programs varied between 3 and 12 weeks, with a weekly frequency of 3 to 6 sessions, one to two sessions per day, with each session lasting 20 to 50 minutes. Conclusions: Pulmonary rehabilitation, which includes strength training, endurance training, and aerobic capacity training, showed a positive effect on improving dyspnea, aerobic capacity, muscle strength, lung function, quality of life, and functionality in patients with post-COVID-19 sequelae.


  • Open Access

    Design and Technical Validation of a Novel O2 Mixed Fitting for Dual Connection in Medical Oxygen Delivery Systems

    by Oscar Ivan Quintero Osorio, Berkan Basançelebi, Elinaldo da Conceição dos Santos, Sergio I Prada, David Alexander Lemos, Andrés Felipe Domínguez, Antonio M Esquinas

    Background: Medical oxygen delivery systems require adaptable connection interfaces capable of supporting different clinical configurations during oxygen therapy. Integrating multifunctional connection mechanisms within a single component offers an opportunity to improve system versatility and connection management in respiratory care settings. Objective: To design and experimentally validate a novel dual-connection fitting for medical oxygen delivery, designated as the O2 Mixed Fitting, that enables simultaneous attachment of both a bubble humidifier and conventional oxygen tubing while remaining installed on the flowmeter. Methods: A comprehensive state-of-the-art review informed the conceptual development of the device. Iterative design refinement was performed using computer-aided design. The final device was manufactured by injection molding using medical-grade Acrylonitrile Butadiene Styrene. Validation included gas flow analysis, leak and pressure-holding tests, microbiological and physical stability evaluation under controlled climatic conditions, and sustainability assessment using a structured eco-design framework. Results: The integrated dual-connection mechanism enabled transition between humidified and non-humidified oxygen delivery without detachment from the flowmeter. Gas flow measurements remained within predefined accuracy tolerances, including ± 0.5 L/min at low flows and ± 10% at higher flows. No leakage was detected during pressure testing up to 10 psi. During the 12-month natural stability study, physical and microbiological parameters remained within predefined acceptance criteria under climatic zone IVb conditions. The eco-design assessment demonstrated favorable environmental performance. Conclusion: The O2 Mixed Fitting represents an innovative dual-connection solution for medical oxygen delivery applications. Laboratory validation confirmed structural integrity, flow stability, pressure resistance, and physical and microbiological stability under the evaluated conditions. The integrated design enhances functional versatility while maintaining full compatibility with existing clinical infrastructure. Further clinical and operational studies are warranted to evaluate its potential impact on patient care and clinical workflow.

  • Open Access

    Design of a glove dispenser to promote rational glove use and hand hygiene in an intensive care unit

    by David Alexander Lemos Martinez, Helen Johana Ortíz Rojas, Stephanie Pabón Lozano, Sergio Prada, Carolina Castro Gomez

    Introduction. Healthcare-associated infections continue to pose a significant challenge in intensive care units (ICUs), where inappropriate glove use and poor hand hygiene can contribute to pathogen transmission and the unnecessary consumption of resources. Gloves represent an essential protective barrier against exposure to potentially infectious biological material, including blood, body fluids, and secretions. Objective. To design, develop, and evaluate a glove dispenser intended to promote appropriate glove use and support hand hygiene practices in an intensive care unit (ICU). Materials and Methods. A technological design study was conducted between January 2023 and January 2024 following a five-phase development process: needs assessment, device specification, concept generation, prototype development and refinement, and final prototype construction. The process incorporated direct clinical observations, feedback from ICU healthcare personnel, iterative usability testing, and pilot implementation in a real clinical setting. Results. A glove dispenser prototype integrated with an alcohol-based hand sanitizer dispenser was developed, incorporating visual prompts based on World Health Organization recommendations to encourage appropriate glove use and hand hygiene. During pilot implementation, 50 healthcare workers participated. Exposure to body fluids was observed in 60% of procedures; glove use was indicated in 72% of cases; 88% of participants used a single pair of gloves per procedure; and 88% reported performing hand hygiene after glove removal. Conclusion. The proposed device represents a technological strategy designed to support appropriate glove use and reinforce hand hygiene practices. Its potential impact on infection prevention and resource optimization should be evaluated in future studies.

  • Open Access

    Effects of an exercise program on physiological variables and 6 Minute walk test in obesity

    by Alejandro Segura Ordoñez, Sebastian Yara Muñoz, Nathali Carvajal, David Alexander Lemos Martínez, José Guillermo Ortega, Mildrey Mosquera

    Introduction: Obesity represents a clinical and public health challenge that requires comprehensive, evidence-based strategies. Objective: To describe changes in aerobic capacity and physiological variables in adults with grade II and III obesity after participating in a multidisciplinary program that included supervised exercise, nutritional support, and psychological counseling. Methodology: Prospective longitudinal study based on the medical records of patients who completed 24 or 36 supervised exercise sessions (twice a week, 60 minutes). Aerobic capacity was assessed using the six-minute walk test (6MWT), and anthropometric, hemodynamic, and respiratory variables were recorded before and after the intervention. Results: Sixty-two patients (83.9% women) were included, of whom 67.7% had at least one comorbidity. After the program, significant reductions in body weight and body mass index (p < 0.05) were observed, with moderate to large effect sizes. The 6MWT showed significant improvements in heart rate, respiratory rate, and systolic and diastolic blood pressure, while changes in oxygen saturation were minimal and clinically irrelevant. The distance walked increased by an average of 22 meters, accompanied by modest increases in estimated VO₂ and METs. However, most changes did not reach clinically relevant thresholds. Conclusions: Completing a multidisciplinary program with supervised moderate-to-vigorous exercise improved some functional and physiological parameters in adults with severe obesity, although the magnitude of the benefits was limited, highlighting the need for longer and more intensive interventions.