Satish
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Satish has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Kushal Sen
Department of Textile Technology Indian Institute of Technology New Delhi India
2 shared publicationsSneh Anand
Centre for Biomedical Engineering Indian Institute of Technology New Delhi India
2 shared publicationsBabita
LF, HF Impedance and DC Metrology, CSIR-NPL
1 shared publicationJ. C. Biswas
CSIR-National Physical Laboratory
1 shared publicationJyoti Swami
Amity University
1 shared publication- Kushal Sen
Department of Textile and Fibre Engineering, Indian Institute of Technology
1 shared publication
Latest Publications
- 28 July 2022
- Published by Springer Nature
- p. 85-90
Establishment of Metrological Traceability of AC Resistance Using Electrical Equivalent Circuit at CSIR-NPL
- 28 July 2022
- Published by Springer Nature
- p. 85-90
Establishment of Metrological Traceability of AC Resistance Using Electrical Equivalent Circuit at CSIR-NPL
- Open Access
- 8 April 2021
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 15 (7) , 562-568
Analysis of glucose‐dependent dielectric properties of aqueous‐based solution: A proof of concept
In spite of widespread research and exploration, the status of non‐invasive blood glucometer for diabetic people is far from satisfactory. This unlocks the prospect for further significant research in the field of non‐invasive blood glucose sensing. An approach towards the research on the development of non‐invasive blood glucometer relies on the establishment of correlation, if any, exists between the dielectric properties of blood and the blood glucose level. In this context, the in‐vitro study is undertaken as a proof of concept using a standard liquid‐dielectric‐test‐fixture. The research is conducted to analyse the variation in dielectric properties of aqueous‐based solution with respect to glucose concentration by utilising test fixture. The employed measurement set‐up and the procedure used for the estimation of dielectric properties (complex‐relative‐permittivity and dissipation factor) of the solution under test are presented. The measurement set‐up is validated by determining the dielectric properties of the reference liquid. The evaluation of uncertainty‐in‐measurement in the complex‐relative‐permittivity and dissipation factor is also provided in detail. However, the variation in dielectric properties is found to be small under tested conditions, and the in‐vitro study conducted out in the perspective of proof of concept has provided an insight that the change in glucose concentration results in quantifiable variation in dielectric properties.
- 8 April 2021
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 15 (7) , 562-568
Open AccessAnalysis of glucose‐dependent dielectric properties of aqueous‐based solution: A proof of concept
In spite of widespread research and exploration, the status of non‐invasive blood glucometer for diabetic people is far from satisfactory. This unlocks the prospect for further significant research in the field of non‐invasive blood glucose sensing. An approach towards the research on the development of non‐invasive blood glucometer relies on the establishment of correlation, if any, exists between the dielectric properties of blood and the blood glucose level. In this context, the in‐vitro study is undertaken as a proof of concept using a standard liquid‐dielectric‐test‐fixture. The research is conducted to analyse the variation in dielectric properties of aqueous‐based solution with respect to glucose concentration by utilising test fixture. The employed measurement set‐up and the procedure used for the estimation of dielectric properties (complex‐relative‐permittivity and dissipation factor) of the solution under test are presented. The measurement set‐up is validated by determining the dielectric properties of the reference liquid. The evaluation of uncertainty‐in‐measurement in the complex‐relative‐permittivity and dissipation factor is also provided in detail. However, the variation in dielectric properties is found to be small under tested conditions, and the in‐vitro study conducted out in the perspective of proof of concept has provided an insight that the change in glucose concentration results in quantifiable variation in dielectric properties.
- 22 November 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 131-137
Characterization of Capacitance Standards at High Frequency at National Physical Laboratory, India
- 22 November 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 131-137
Characterization of Capacitance Standards at High Frequency at National Physical Laboratory, India
- 15 November 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 185-190
Impedance Spectroscopy of Aqueous Solution Samples of Different Glucose Concentrations for the Exploration of Non-Invasive-Continuous-Blood-Glucose-Monitoring
- 15 November 2017
- Published by Springer Nature in MAPAN
- Vol. 33 (2) , 185-190
Impedance Spectroscopy of Aqueous Solution Samples of Different Glucose Concentrations for the Exploration of Non-Invasive-Continuous-Blood-Glucose-Monitoring
- 12 July 2016
- Published by Springer Nature in MAPAN
- Vol. 31 (3) , 225-230
Determination of Glucose-Dependent Dielectric Properties of Ringer Lactate Using Open-Ended Coaxial Probe Method
- 12 July 2016
- Published by Springer Nature in MAPAN
- Vol. 31 (3) , 225-230
Determination of Glucose-Dependent Dielectric Properties of Ringer Lactate Using Open-Ended Coaxial Probe Method