XJXiaosong Jiang

Xiaosong Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaosong Jiang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deciphering the “non-verbal” code: A preliminary exploration of multimodal large language models for neonatal pain recognition

    by Xiaosong Jiang, Nannan Yang, Tingqi Shi, Xiaoyan Lu, Mingjing Fang, Hui Yang, Jianzheng Cai

    Background: Neonatal pain assessment primarily relies on behavioral rating scales. Although these tools provide objective measures, their scores are susceptible to inter-rater variability, potentially introducing bias. Moreover, intermittent assessments cannot capture pain progression over time. Multimodal large language models (MLLMs) offer a novel approach to addressing these limitations; however, their effectiveness in neonatal pain recognition remains largely unexplored. Objective: This study aimed to evaluate the performance of several MLLMs in neonatal pain video classification and investigate their applicability, limitations, and potential for clinical implementation. Methods: A previously established, annotation-validated multimodal dataset of acute neonatal pain was used. The dataset comprised 426 video recordings of neonatal heel lance procedures. Three MLLMs with dynamic video analysis capabilities (Qwen3-VL-Plus, Gemini-3-Pro, and ERNIE-4.5-Turbo) were evaluated. Carefully designed prompts guided the models to simulate nurses’ pain assessments. Model performance was comprehensively evaluated using accuracy, weighted Cohen’s kappa coefficient, precision, recall, and F1 score. Results: Gemini-3-Pro achieved the best classification performance, with an accuracy of 86.9% and a weighted kappa coefficient of 0.695, followed by Qwen3-VL-Plus (83.6%, kappa = 0.624) and ERNIE-4.5-Turbo (78.4%, kappa = 0.563). Gemini-3-Pro demonstrated an excellent recall of 0.974 and an F1 score of 0.905 for the pain category. However, all models showed relatively lower recall for the no-pain category (0.664–0.868), suggesting a trade-off between pain and no-pain classification and indicating challenges in achieving both high sensitivity and specificity. Conclusion: MLLMs demonstrate considerable potential for neonatal pain assessment, with particularly strong performance in pain screening. Their structured reasoning and interpretable outputs may support clinical decision-making. However, the observed performance imbalance between pain and no-pain classification suggests that these models are not yet capable of independently replacing clinical judgment and are better suited as assistive tools to optimize clinical workflows.

  • Open Access

    The performance boundaries of knowledge prompts: A study on injection strategies and scale effects for ICD coding tasks in large language models

    by Xiaosong Jiang, Chen Wang, Guxue Shan, Zhimao Wu, Ping Li, Yanxing Yang, Siyu Zha, Li Liu, Tingqi Shi

    Background: International Classification of Diseases (ICD) coding is essential for health insurance reimbursement, healthcare delivery, and public health management, supporting quality assessment, cost control, and clinical research. Traditional ICD coding relies on manual processes that are labor-intensive, time-consuming, and prone to human error. Large language models (LLMs) offer a promising approach for automating medical record coding; however, their clinical application is limited by the complexity of medical records and the highly specialized nature of clinical knowledge. Objective: This study aims to evaluate the effects of different knowledge-based prompting strategies on LLMs’ ICD coding performance, identify optimal combinations of models and prompts, and assess their effectiveness in real-world medical record coding tasks. Methods: A total of 800 discharge summaries from the Department of Urology at the First Affiliated Hospital of Soochow University, dated between 1 January and 31 May 2025, were randomly selected to construct a standardized dataset. The study was conducted in two stages. First, five prompting strategies were evaluated using GPT-4o across primary diagnosis, secondary diagnosis, and surgical procedure coding to identify the optimal strategy. Second, this strategy was applied to multiple LLMs to compare coding performance. Results: Contextual prompting tailored to medical specialties achieved the best performance with GPT-4o, with accuracies of 84%, 85%, and 82% for the three coding tasks. Using this strategy, DeepSeek-V3 achieved the highest overall performance, with accuracies of 89.5%, 88.6%, and 93.3%, respectively. Conclusion: An integrated framework combining contextual prompting with DeepSeek-V3 substantially improves automated ICD coding accuracy and efficiency, demonstrating strong potential for clinical application.

  • Open Access

    Feasibility and Effectiveness of a Low-Code AI Platform for Developing a Neonatal Multimodal Pain Classification Model

    by Nannan Yang, Xiaosong Jiang, Xue Jin, Xinran Dai, Yuanjing Gu, Huiping Jiang, Liping Pu, Tingqi Shi

    Background: Artificial intelligence (AI) has advanced neonatal pain recognition, yet a significant gap persists in translating complex algorithms into practical clinical applications. Low-code AI development platforms, which simplify and automate model creation, offer a potential solution to bridge this gap between research and bedside practice. Objective: This study aimed to explore the feasibility of constructing and validating a neonatal multimodal pain classification model using a commercial low-code AI development platform (EasyDL). The objective was to develop an accessible, cost-effective, and efficient method that empowers clinical professionals to create their own AI tools without extensive programming expertise. Methods: We uploaded 426 neonatal acute pain multimodal data segments to the EasyDL platform and trained a video classification model using its AutoML capabilities. The model underwent internal testing on a held-out dataset portion, followed by external validation on an independent prospective cohort. For external validation, we compared model performance against the N-PASS (Neonatal Pain, Agitation, and Sedation Scale) scores assessed by a senior nurse as the clinical gold standard. Results: The neonatal multimodal pain classification model developed on the platform showed strong performance. Internal validation achieved 89.6% accuracy and an 85.8% F1 score. External validation on unseen data reached 87.7% accuracy, with AUC exceeding 0.95 across all pain categories (no pain, mild pain, severe pain). The streamlined development process enabled seamless API deployment to an Android mobile device for clinical use. Conclusion: Developing a neonatal multimodal pain classification model using a low-code AI platform proves both feasible and effective. The model demonstrates robust performance and strong clinical integration potential. This approach offers a practical pathway to democratize AI development, enabling healthcare professionals to create digital solutions for neonatal pain management.