MacAulay Harvey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
MacAulay Harvey has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Danielle Tokarz
Department of Chemistry, Saint Mary’s University, 923 Robie Street, Halifax, Nova Scotia, B3H 3C3, Canada
3 shared publications - Richard Cisek
Department of Chemistry, Saint Mary's University, 923 Robie Street, Halifax, Nova Scotia B3H 3C3, Canada
3 shared publications Katherine Zinck
2 shared publicationsSaranyan Pillai
Dalhousie University
2 shared publicationsSean D. Christie
Dalhousie University
2 shared publicationsCaylee MacDonald
Department of Chemistry, Saint Mary's University, 923 Robie Street, Halifax, NS, B3H 3C3, Canada
1 shared publication
Latest Publications
- 21 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 851-871
Characterization of inner ear granular bodies by polarization-resolved second harmonic generation microscopy
Otoconia and corpuscles dissected from the inner ear of mice were investigated using polarization-resolved second harmonic generation microscopy (PSHG) to extract ultrastructural parameters. The PSHG parameter, ρ , typically related to helical tilt in collagen, was calculated for each image pixel, and the average ρ values were found to be 4.6 for corpuscles and -3.3 for otoconia. The negative ρ from otoconia was measured unambiguously, indicating that the symmetry of SHG emitters is not predominantly uniaxial, in contrast to typical biological SHG emitters such as collagen, myosin, or starch. The internal distribution of ρ values of corpuscles was radial and resembled the average ρ values of starch. Simulating otoconia structure as consisting of a biaxial system with two similar emitters > 90° apart predicts that disorder alters the measured ρ values, making them increasingly negative. An SHG measurement of otoconia during degradation was performed, revealing that the ρ values of otoconia significantly decrease with degradation in agreement with this model.
- 21 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 851-871
Characterization of inner ear granular bodies by polarization-resolved second harmonic generation microscopy
Otoconia and corpuscles dissected from the inner ear of mice were investigated using polarization-resolved second harmonic generation microscopy (PSHG) to extract ultrastructural parameters. The PSHG parameter, ρ , typically related to helical tilt in collagen, was calculated for each image pixel, and the average ρ values were found to be 4.6 for corpuscles and -3.3 for otoconia. The negative ρ from otoconia was measured unambiguously, indicating that the symmetry of SHG emitters is not predominantly uniaxial, in contrast to typical biological SHG emitters such as collagen, myosin, or starch. The internal distribution of ρ values of corpuscles was radial and resembled the average ρ values of starch. Simulating otoconia structure as consisting of a biaxial system with two similar emitters > 90° apart predicts that disorder alters the measured ρ values, making them increasingly negative. An SHG measurement of otoconia during degradation was performed, revealing that the ρ values of otoconia significantly decrease with degradation in agreement with this model.
- 24 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 511
Imaging otoconia by second harmonic generation microscopy: erratum
This errata contains a correction to our published paper [ Biomed. Opt. Express 13 ( 6 ), 3593 ( 2022 ) 10.1364/BOE.457967 ].
- 24 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 511
Imaging otoconia by second harmonic generation microscopy: erratum
This errata contains a correction to our published paper [ Biomed. Opt. Express 13 ( 6 ), 3593 ( 2022 ) 10.1364/BOE.457967 ].
- 12 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 4027-4039
Second harmonic generation of myofibrils exhibits a polarization-resolved “gradient” effect
Polarization-resolved second harmonic generation microscopy (PSHG) was used to investigate the ultrastructure of individual myofibrils and collagen fibrils to visualize the ρ parameter. A gradient in the ρ values was experimentally observed orthogonal to the myofibrils, and numerical focal volume simulations were performed, indicating myosin SHG has an imaginary chiral component, similar to collagen fibrils. Both types of fibrils were re-imaged after a 180° rotation to investigate the physical mechanism behind the gradient effect. A change in the gradient direction was often observed in myofibrils, but less so in collagen, where it was more variable. PSHG is often used to discriminate muscle and collagen diseases, and chiral SHG contributions, which are typically ignored, should be considered when interpreting PSHG data.
- 12 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 4027-4039
Second harmonic generation of myofibrils exhibits a polarization-resolved “gradient” effect
Polarization-resolved second harmonic generation microscopy (PSHG) was used to investigate the ultrastructure of individual myofibrils and collagen fibrils to visualize the ρ parameter. A gradient in the ρ values was experimentally observed orthogonal to the myofibrils, and numerical focal volume simulations were performed, indicating myosin SHG has an imaginary chiral component, similar to collagen fibrils. Both types of fibrils were re-imaged after a 180° rotation to investigate the physical mechanism behind the gradient effect. A change in the gradient direction was often observed in myofibrils, but less so in collagen, where it was more variable. PSHG is often used to discriminate muscle and collagen diseases, and chiral SHG contributions, which are typically ignored, should be considered when interpreting PSHG data.