DLDongguang Li

Dongguang Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dongguang Li has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Haiyu Zhao

    Huazhong University of Science and Technology

    1 shared publication
  • Huashun Sun

    National Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Jiahui Guo

    National Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Jingjia Ke

    Department of Instrument Science and Technology, State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Shuai Wang

    Department of Instrument Science and Technology, State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication
  • Tong Qu

    National Key Laboratory of Intelligent Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan, China

    1 shared publication

Latest Publications

  • Open Access

    Innovative Inverse-Slit Spatial-Filtering Architecture: Structural Advances for Chromatic Line Confocal Three-Dimensional Metrology

    by Haiyu Zhao, Shuai Wang, Jingjia Ke, Zimin An, Yi Tao, Dongguang Li, Tong Qu, XiaoJun Liu

    Chromatic line confocal imaging (LCI) performs optical metrology using the specular reflection from the sample surface. Under low-reflectance conditions, the limited photon flux results in a pronounced reduction in the signal-to-noise ratio (SNR). For high-dynamic-range (HDR) surfaces exhibiting large reflectance variations, a single-exposure dynamic-range mismatch imposes additional constraints: regions of low reflectance become noise-limited and are difficult to image reliably, whereas regions of high reflectance are prone to saturation detector response, consequently limiting the system’s detection capability. To address this issue, based on spectral confocal theory, an innovative inverse-slit spatial filtering architecture is proposed: the conventional light-transmitting slit centered on the optical axis is replaced with a central obscuration, symmetrically flanked by two wide transmission windows. This geometrically inverted design markedly enlarges the collection aperture, thereby improving both native SNR and photon flux. Meanwhile, this spatial-filtering architecture suppresses the central energy of the main lobe in the axial response of the conventional confocal system, introducing a controllable notch at the peak. On this basis, to fully exploit the optical advantages of the inverse-slit during reconstruction, a black top-hat transform is combined with a multiscale Hessian ridge detector and tailored to the inverse-Gaussian dark stripe produced by the axial response. Experimental results show that the inverse-slit architecture substantially improves measurement accuracy and efficiency, enhances robustness to HDR surfaces, and, under low-reflectance conditions, cuts the required exposure time to 15.19% of that needed with a conventional slit.

  • Dual-Wavelength Ranging Accuracy Enhancement Based on Improved Gas Absorption Wavelength Locking

    by Dongguang Li, Yilin Yang, Jiahui Guo, Huashun Sun, Tong Qu, Xiaojun Liu

    In this letter, we propose and experimentally validate an improved method for high-precision locking of the laser center wavelength based on the absorption spectrum of saturated HCN gas, aiming to enhance the repeatability accuracy of dual-wavelength ranging. By combining with high-precision phase-generated carrier displacement measurement technology, we achieved real-time measurement of the target distance. Our experimental results demonstrate that this method achieves excellent stability for the laser center wavelength, with a wavelength uncertainty of only $1.05\times 10^{-8}$ , a resolution better than 1 nm and a stability of 0.58 nm ( $1\sigma $ ), nanoscale displacement measurement is achieved. These enhancements are significant in expanding the application of sine frequency modulation interferometry.