Eleonora Storto
Research Subjects
Eleonora Storto has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Frisoli
Institute of Mechanical Intelligence, Scuola Superiore Sant’Anna, 56127 Pisa, Italy
2 shared publications - Francesco Porcini
IIM Institute, PERCRO Laboratory
2 shared publications Mario Meola
Interdisciplinary Research Center Health Science
1 shared publication- Massimiliano Solazzi
Institute of Mechanical Intelligence, Department of Excellence in Robotics and AI, Sant’Anna School of Advanced Studies
1 shared publication - Valerio Novelli
IIM Institute, Scuola Superiore Sant’Anna of Pisa Italy, Via Alamanni 13b, 56010 Ghezzano, PI, Italy
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2266-2290
Teleoperation Architectures for Remote Ultrasound Diagnostic Imaging: A Systematic Review
Teleultrasound is a promising application of telemedicine, enabling remote diagnostic imaging through teleoperated systems. While previous reviews have addressed various aspects such as clinical applications, autonomy levels, or assistive functionalities, a systematic analysis of teleoperation architectures—the core enabler of remote manipulation and feedback—remains lacking. This paper presents a comprehensive review of thirty-nine teleultrasound systems, focusing specifically on teleoperation architectures. Each system is examined in terms of leader and follower design, control strategies, force-feedback implementation, time delay handling, communication infrastructure, and anatomical targets. The aim of this review is the evaluation of system transparency and stability, analyzed not only in relation to devices' mechanical design and control implementation, but specifically from a comprehensive architectural point of view. Also, the evaluation critically takes into account the realism of the test conditions. Through this lens, the review shows how architectural choices critically shape the performance and safety of remote ultrasound interactions. Open challenges and future directions are also discussed, offering a reference framework for researchers and developers working on next-generation remote ultrasound technologies.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2266-2290
Open AccessTeleoperation Architectures for Remote Ultrasound Diagnostic Imaging: A Systematic Review
Teleultrasound is a promising application of telemedicine, enabling remote diagnostic imaging through teleoperated systems. While previous reviews have addressed various aspects such as clinical applications, autonomy levels, or assistive functionalities, a systematic analysis of teleoperation architectures—the core enabler of remote manipulation and feedback—remains lacking. This paper presents a comprehensive review of thirty-nine teleultrasound systems, focusing specifically on teleoperation architectures. Each system is examined in terms of leader and follower design, control strategies, force-feedback implementation, time delay handling, communication infrastructure, and anatomical targets. The aim of this review is the evaluation of system transparency and stability, analyzed not only in relation to devices' mechanical design and control implementation, but specifically from a comprehensive architectural point of view. Also, the evaluation critically takes into account the realism of the test conditions. Through this lens, the review shows how architectural choices critically shape the performance and safety of remote ultrasound interactions. Open challenges and future directions are also discussed, offering a reference framework for researchers and developers working on next-generation remote ultrasound technologies.
- Open Access
Impact of Force Scaling on Physician Fatigue in a Bilateral Tele-Ultrasound System
Tele-ultrasound systems enable remote diagnostic imaging by transmitting both motion commands and haptic feedback between a sonographer and a robotic probe. While these systems aim to replicate conventional ultrasound procedures, they rarely address the physical strain typically experienced by sonographers. In this study, the effect of applying a force scaling strategy to haptic feedback on reducing muscular fatigue and task-induced stress during a realistic tele-ultrasound task is studied. First, a thorough operational and biomechanical analysis of the abdominal US procedure was performed to reconstruct a representative task in the laboratory. Then, a bilateral position–force tele-ultrasound architecture was implemented, and a total of 11 subjects performed the reconstructed remote ultrasound task under two randomized conditions: with and without force scaling. Surface electromyography (sEMG) signals were acquired from seven upper-limb muscles (posterior deltoid, trapezius, anterior deltoid, biceps, triceps, wrist flexors, and wrist extensors). Teleoperation-related stress was also assessed using a seven-item Likert-scale self-report questionnaire administered after each trial. Statistical significance was tested using Repeated Measures ANOVA for EMG data and the Wilcoxon signed-rank test for stress scores. The results showed a statistically significant reduction in muscle activation in 5 out of 7 muscles, and a clear mitigation of fatigue progression over time in the scaled condition. Additionally, perceived stress levels were significantly lower in the presence of force scaling in overall stress scores. These findings support the effectiveness of force scaling as a tool to enhance ergonomics in tele-ultrasound procedures without compromising the operator’s ability to perform the task. The proposed methodology proved robust and generalizable, offering valuable insight into the integration of human-centered design in tele-operated diagnostic systems.
Open AccessImpact of Force Scaling on Physician Fatigue in a Bilateral Tele-Ultrasound System
Tele-ultrasound systems enable remote diagnostic imaging by transmitting both motion commands and haptic feedback between a sonographer and a robotic probe. While these systems aim to replicate conventional ultrasound procedures, they rarely address the physical strain typically experienced by sonographers. In this study, the effect of applying a force scaling strategy to haptic feedback on reducing muscular fatigue and task-induced stress during a realistic tele-ultrasound task is studied. First, a thorough operational and biomechanical analysis of the abdominal US procedure was performed to reconstruct a representative task in the laboratory. Then, a bilateral position–force tele-ultrasound architecture was implemented, and a total of 11 subjects performed the reconstructed remote ultrasound task under two randomized conditions: with and without force scaling. Surface electromyography (sEMG) signals were acquired from seven upper-limb muscles (posterior deltoid, trapezius, anterior deltoid, biceps, triceps, wrist flexors, and wrist extensors). Teleoperation-related stress was also assessed using a seven-item Likert-scale self-report questionnaire administered after each trial. Statistical significance was tested using Repeated Measures ANOVA for EMG data and the Wilcoxon signed-rank test for stress scores. The results showed a statistically significant reduction in muscle activation in 5 out of 7 muscles, and a clear mitigation of fatigue progression over time in the scaled condition. Additionally, perceived stress levels were significantly lower in the presence of force scaling in overall stress scores. These findings support the effectiveness of force scaling as a tool to enhance ergonomics in tele-ultrasound procedures without compromising the operator’s ability to perform the task. The proposed methodology proved robust and generalizable, offering valuable insight into the integration of human-centered design in tele-operated diagnostic systems.