Lei Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lei Lu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guihui Zhong
Department of Hydraulic Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Qiuping Wang
Department of Hydraulic Engineering, College of Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Qunfang Hu
Tongji University
1 shared publication - Shengxin Xu
Department of Hydraulic Engineering, College of Civil Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Shuguang Liu
College of Civil Engineering, Tongji University, Shanghai, China
1 shared publication - Zhan Su
Shanghai Institute of Disaster Prevention and Relief, Tongji University, Shanghai 200092, China
1 shared publication
Latest Publications
- Open Access
A Method for Improving the Efficiency and Effectiveness of Automatic Image Analysis of Water Pipes
The integrity of urban water supply pipelines, an essential element of municipal infrastructure, is frequently undermined by internal defects such as corrosion, tuberculation, and foreign matter. Traditional inspection methods relying on CCTV are time-consuming, labor-intensive, and prone to subjective interpretation, which hinders the timely and accurate assessment of pipeline conditions. This study proposes YOLOv8-VSW, a systematically optimized and lightweight model based on YOLOv8 for automated defect detection in in-service pipelines. The framework is twofold: First, to overcome data limitations, a specialized defect dataset was constructed and augmented using photometric transformation, affine transformation, and noise injection. Second, the model architecture was improved on three levels: a VanillaNet backbone was adopted for lightweighting, a C2f-Star module was introduced to enhance multi-scale feature fusion, and the WIoUv3 dynamic loss function was employed to improve robustness under complex imaging conditions. Experimental results demonstrate the superior performance of the proposed YOLOv8-VSW model. This study validates the framework on a curated, real-world image dataset, where YOLOv8-VSW achieved mAP@50 of 83.5%, a 4.0% improvement over the baseline. Concurrently, GFLOPs were reduced by approximately 38.9%, while the inference speed was increased to 603.8 FPS. The findings validate the effectiveness of the proposed method, delivering a solution that effectively balances detection accuracy, computational efficiency, and model size. The results establish a strong technical basis for the intelligent and automated control of safety in urban water supply systems.
Open AccessA Method for Improving the Efficiency and Effectiveness of Automatic Image Analysis of Water Pipes
The integrity of urban water supply pipelines, an essential element of municipal infrastructure, is frequently undermined by internal defects such as corrosion, tuberculation, and foreign matter. Traditional inspection methods relying on CCTV are time-consuming, labor-intensive, and prone to subjective interpretation, which hinders the timely and accurate assessment of pipeline conditions. This study proposes YOLOv8-VSW, a systematically optimized and lightweight model based on YOLOv8 for automated defect detection in in-service pipelines. The framework is twofold: First, to overcome data limitations, a specialized defect dataset was constructed and augmented using photometric transformation, affine transformation, and noise injection. Second, the model architecture was improved on three levels: a VanillaNet backbone was adopted for lightweighting, a C2f-Star module was introduced to enhance multi-scale feature fusion, and the WIoUv3 dynamic loss function was employed to improve robustness under complex imaging conditions. Experimental results demonstrate the superior performance of the proposed YOLOv8-VSW model. This study validates the framework on a curated, real-world image dataset, where YOLOv8-VSW achieved mAP@50 of 83.5%, a 4.0% improvement over the baseline. Concurrently, GFLOPs were reduced by approximately 38.9%, while the inference speed was increased to 603.8 FPS. The findings validate the effectiveness of the proposed method, delivering a solution that effectively balances detection accuracy, computational efficiency, and model size. The results establish a strong technical basis for the intelligent and automated control of safety in urban water supply systems.