Marshall Wilson
Research Subjects
Research Interests
Marshall Wilson has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Savtchouk
Semilab SDI
2 shared publications - Birgit Kallinger
Fraunhofer IISB
2 shared publications - Carlos Almeida
Semilab SDI
2 shared publications - Gennadi Polisski
Semilab
2 shared publications - Jacek Lagowski
Semilab SDI
2 shared publications - Liliana Gutierrez
Semilab SDI
2 shared publications
Latest Publications
- Open Access
- 19 May 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1191, 29-35
Evaluation of Oxide Processing Steps in SiC Technology Using Contactless Corona-Based CV Measurements
An area of increasing interest for SiC device processing is the processing and qualification of silicon oxides. In this article a contactless corona CV (CnCV) measurement procedure is evaluated as a way to gain more knowledge about the different processes related to oxides. A 21-point measurement pattern is used to gain information about uniformity of oxide properties. Two different types of oxides have been considered, low pressure chemical vapor deposited (CVD) oxides using tetraethylorthosilicate (TEOS) and thermally grown oxides. The two different groups have received different combinations of pre- and post-processing steps prior to measurements. As expected, low pressure CVD (LPCVD) and thermally grown SiO 2 without any post oxidation annealing (POA) showed significantly different electrical characteristics compared to the wafers that did get a POA. This difference could clearly be distinguished by CnCV, meaning that individual process steps can be analyzed without the fabrication of any test structures on the wafers. As the individual process steps can be analyzed, the uniformity of the individual steps can be accessed. Using a 21-point pattern it was possible to show that there is a non-uniformity in the LPCVD process used prior to the POA. This makes the CnCV technique suitable for in-line characterization and process monitoring.
- 19 May 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1191, 29-35
Open AccessEvaluation of Oxide Processing Steps in SiC Technology Using Contactless Corona-Based CV Measurements
An area of increasing interest for SiC device processing is the processing and qualification of silicon oxides. In this article a contactless corona CV (CnCV) measurement procedure is evaluated as a way to gain more knowledge about the different processes related to oxides. A 21-point measurement pattern is used to gain information about uniformity of oxide properties. Two different types of oxides have been considered, low pressure chemical vapor deposited (CVD) oxides using tetraethylorthosilicate (TEOS) and thermally grown oxides. The two different groups have received different combinations of pre- and post-processing steps prior to measurements. As expected, low pressure CVD (LPCVD) and thermally grown SiO 2 without any post oxidation annealing (POA) showed significantly different electrical characteristics compared to the wafers that did get a POA. This difference could clearly be distinguished by CnCV, meaning that individual process steps can be analyzed without the fabrication of any test structures on the wafers. As the individual process steps can be analyzed, the uniformity of the individual steps can be accessed. Using a 21-point pattern it was possible to show that there is a non-uniformity in the LPCVD process used prior to the POA. This makes the CnCV technique suitable for in-line characterization and process monitoring.
- Open Access
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 63-69
Non-Contact Full Wafer Imaging of Electrically Active Defects in 4H-SiC Epi with Comparison to End of Line Electrical Device Data
In this work we present the results of a comparison between the non-contact corona-based QUAD (Quality, Uniformity and Defects) technique for inline mapping of electrically active defects in SiC epi and final wafer level electrical device data on merged PiN Schottky diodes. A new defect analysis method for the QUAD mapping is introduced that involves the creation of a die yield bin map using the in-die values of depletion voltage that facilitates the comparison to the wafer level final electrical device data. Excellent correlation of the QUAD wafer bin map results to the final wafer level electrical device data was observed, illustrating that QUAD mapping of defects in SiC epi can provide a powerful and convenient inline complement to UVPL measurements for determining which defects are electrically active and will impact device performance.
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 63-69
Open AccessNon-Contact Full Wafer Imaging of Electrically Active Defects in 4H-SiC Epi with Comparison to End of Line Electrical Device Data
In this work we present the results of a comparison between the non-contact corona-based QUAD (Quality, Uniformity and Defects) technique for inline mapping of electrically active defects in SiC epi and final wafer level electrical device data on merged PiN Schottky diodes. A new defect analysis method for the QUAD mapping is introduced that involves the creation of a die yield bin map using the in-die values of depletion voltage that facilitates the comparison to the wafer level final electrical device data. Excellent correlation of the QUAD wafer bin map results to the final wafer level electrical device data was observed, illustrating that QUAD mapping of defects in SiC epi can provide a powerful and convenient inline complement to UVPL measurements for determining which defects are electrically active and will impact device performance.
- Open Access
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 19-26
Coherency between Epitaxial Defectivity, Surface Voltage, Photoluminescence Mapping and Electrical Wafer Sorting for 200mm SiC Wafers
Electrical Wafer Sorting (EWS) on 12 000, 650 V SiC MOSFETs devices from 7 wafers of 200 mm 4H-SiC are compared with electrical deviations and defectivity of initial epitaxial layers measured using Charge biased non-Contact Voltage imaging, QUAD (Quality Uniformity And Defects), and optical surface detection with PL-imaging, respectively. We successfully demonstrate an increased prediction rate in both KR (kill-ratio) and YI (yield-impact) compared to conventional PL-imaging. It is also shown that QUAD not only supplements PL-imaging but supersedes it predicting failure in some electrical test conditions. We therefore show that the combination of QUAD and PL-imaging results significantly improves the accuracy of device failure prediction by uniquely locating faults in the wafers, and thus, improving foresight of successful device fabrication.
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 19-26
Open AccessCoherency between Epitaxial Defectivity, Surface Voltage, Photoluminescence Mapping and Electrical Wafer Sorting for 200mm SiC Wafers
Electrical Wafer Sorting (EWS) on 12 000, 650 V SiC MOSFETs devices from 7 wafers of 200 mm 4H-SiC are compared with electrical deviations and defectivity of initial epitaxial layers measured using Charge biased non-Contact Voltage imaging, QUAD (Quality Uniformity And Defects), and optical surface detection with PL-imaging, respectively. We successfully demonstrate an increased prediction rate in both KR (kill-ratio) and YI (yield-impact) compared to conventional PL-imaging. It is also shown that QUAD not only supplements PL-imaging but supersedes it predicting failure in some electrical test conditions. We therefore show that the combination of QUAD and PL-imaging results significantly improves the accuracy of device failure prediction by uniquely locating faults in the wafers, and thus, improving foresight of successful device fabrication.
- Open Access
- 5 September 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1157, 49-56
Recent Advancement in Noncontact Wafer Level Electrical Characterization for WBG Technologies
A breakthrough high throughput WBG semiconductor dopant monitoring method has recently been introduced based on the novel concept of sweeping the electrical bias by near UV illumination-induced photoneutralization of corona charge. As originally discovered for 4H-SiC, the doping determination can be realized using the value of the photoneutralization time constant. In the present work this procedure is tested for β-Ga2O3 with a larger energy gap of 4.8eV, using a correspondingly deeper UV range. Such deep UV application to the AlGaN/GaN HEMT structure resulted in the development of a new measurement principle capable of increasing the HEMT wafer measurement throughput 10 times compared to previous corona noncontact C-V metrology. The new principle involves a linear illumination-induced corona charge bias sweep. Combined with surface voltage monitoring, it provides a means for fast and precise determination of the pinch-off voltage, VP, the AlGaN electrical thickness, and the 2D electron gas density.
- 5 September 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1157, 49-56
Open AccessRecent Advancement in Noncontact Wafer Level Electrical Characterization for WBG Technologies
A breakthrough high throughput WBG semiconductor dopant monitoring method has recently been introduced based on the novel concept of sweeping the electrical bias by near UV illumination-induced photoneutralization of corona charge. As originally discovered for 4H-SiC, the doping determination can be realized using the value of the photoneutralization time constant. In the present work this procedure is tested for β-Ga2O3 with a larger energy gap of 4.8eV, using a correspondingly deeper UV range. Such deep UV application to the AlGaN/GaN HEMT structure resulted in the development of a new measurement principle capable of increasing the HEMT wafer measurement throughput 10 times compared to previous corona noncontact C-V metrology. The new principle involves a linear illumination-induced corona charge bias sweep. Combined with surface voltage monitoring, it provides a means for fast and precise determination of the pinch-off voltage, VP, the AlGaN electrical thickness, and the 2D electron gas density.