JGJoseph Gyesi

Joseph Gyesi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph Gyesi has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-Resolution Microtesla In-Situ 13C NMR Detection of “Scaled-Up” SABRE-Hyperpolarization of [1-13C]Pyruvate

    by Abubakar Abdurraaheem, Joseph N. Gyesi, Shiraz Nantogma, Patrick TomHon, Anna Samoilenko, Clementinah Oladun, Boyd M. Goodson, Matthew S. Rosen, Thomas Theis, Charlie Fehl, et al.

    SABRE-SHEATH (Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei) is a parahydrogen-based hyperpolarization technique increasingly used for metabolic sensing. Typically limited to 5-mm NMR tube reactors (0.5–1 mL volumes) and requiring manual sample transfer for quantification, SABRE remains constrained by its throughput. Here, we describe a new low-field magnetic resonance system that enables in-situ polarimetry of hyperpolarized [1-13C]pyruvate. This setup utilizes a mu-metal shielded solenoid magnet, performing hyperpolarization at 0.4 µT (SABRE-SHEATH) and in-situ NMR sensing at 140 µT (1.6 kHz 13C frequency), which eliminates the need for sample transfer. We demonstrate that a surface-coil detection design accommodates diverse sample geometries, including 15-mm ID HPLC columns. By increasing the parahydrogen flow rate 12-fold, we successfully scaled the production of [1-13C]pyruvate to a 10-mL volume, achieving a 7% polarization level—comparable to that of smaller 0.8-mL samples. Furthermore, the integration of automated fluidics and a saddle-shaped RF excitation coil enables both SABRE-SHEATH and Spin-Lock Induced Crossing (SLIC)-SABRE protocols. Notably, we demonstrate the utility of this in-situ detection for optimizing SABRE conditions, including the screening of DMSO concentrations. Finally, the ability to operate with diverse solvent systems and scalable volumes lays the foundation for producing biocompatible hyperpolarized formulations, broadening the potential for metabolic research. These advances establish a scalable, automated framework for producing larger, biocompatible volumes of hyperpolarized molecular probes.

  • Biocompatible SABRE Hyperpolarization of [1‐ 13 C]Ketoleucine for Cellular Metabolic Flux Sensing

    by Patrick TomHon, Joseph Gyesi, Abubakar Abdurraheem, Stephen McBride, Anna Samoilenko, Clementinah Oladun, Erica Curran, Megan Pike, Sydney D. Welch, Sydney Scofield, et al.

    Ketoleucine (α‐ketoisocaproate) is a novel hyperpolarized substrate for noninvasive metabolic imaging, enabling rapid, high‐sensitivity detection of branched‐chain amino acid flux, a pathway that is aberrant in many diseases including cancer and Alzheimer's disease. Utilizing NMR Signal Amplification by Reversible Exchange (SABRE) with an 80:20 acetone:water solvent system, we achieved >11% polarization of [1‐ 13 C]ketoleucine (corresponding to signal enhancement over 230,000‐fold at 0.55 T) at 70 mM within 2 min, using parahydrogen as a cheap and fast source of hyperpolarization. A two‐stage liquid–liquid extraction and gas stripping protocol removes excess excipients, yielding a biocompatible aqueous solution of [1‐ 13 C]ketoleucine (79 ± 10 mM). When mixed with Saccharomyces cerevisiae (Baker's yeast), hyperpolarized [1‐ 13 C]ketoleucine produced strong, long‐lasting signals, where downstream metabolites are observed for >200 s, allowing first‐order kinetic modeling of CO 2 and bicarbonate. These cell experiments demonstrate both the biocompatibility and signal strength of SABRE–hyperpolarized KL, establishing KL as a versatile hyperpolarized agent and opening avenues for real‐time investigation of metabolic dysregulation in cancer, neurodegenerative disorders, and beyond.


  • Open Access

    SABRE Ir-IMes Catalysis for the Masses

    by Izabelle Smith, Noah Terkildsen, Zachary Bender, Abubakar Abdurraheem, Shiraz Nantogma, Anna Samoilenko, Joseph Gyesi, Larisa M. Kovtunova, Oleg G. Salnikov, Igor V. Koptyug, et al.

    The Signal Amplification By Reversible Exchange (SABRE) technique provides enhancement of Nuclear Magnetic Resonance (NMR) signals up to several orders of magnitude using chemical exchange of a substrate and parahydrogen on an iridium complex. Therefore, the availability of such a catalytic complex to a broader community is an absolutely vital step for dissemination of the groundbreaking SABRE methodology. The most common SABRE catalyst, which is activated in situ, is based on Ir-IMes system (IMes = 1,3-Bis(2,4,6-trimethylphenyl)imidazol-2-ylidene). Earlier approaches for the synthesis of this catalyst often relied on specialized equipment and were limited to a comparatively small scale. This, in turn, increased the barrier of entry for new scientists to the area of SABRE hyperpolarization. Here, we present a robust, inexpensive, and easy to reproduce synthetic procedure for the preparation of this SABRE catalyst, which does not require specialized inert atmosphere equipment like a glove box or Schlenk line. The synthesis was validated on the scale of several grams vs. tens of milligrams scale in the reported approaches. The resulting SABRE catalyst, [Ir(IMes)(COD)Cl], was activated in situ and further evaluated in hyperpolarization experiments resulting in signal enhancements comparable to (or higher than) those for the catalyst prepared using Schlenk line equipment.


  • Open Access

    Parahydrogen-Based Hyperpolarization for the Masses at Millitesla Fields

    by Garrett L. Wibbels, Clementinah Oladun, Tanner Y. O’hara, Isaiah Adelabu, Joshua E. Robinson, Firoz Ahmed, Zachary T. Bender, Anna Samoilenko, Joseph Gyesi, Larisa M. Kovtunova, et al.

    Hyperpolarization (HP) techniques, such as Parahydrogen-Induced Polarization (PHIP), Signal Amplification by Reversible Exchange (SABRE), and dissolution Dynamic Nuclear Polarization (d-DNP), significantly enhance the sensitivity of nuclear magnetic resonance (NMR) spectroscopy for chemical analysis and metabolic imaging. However, the high cost of equipment, ranging from tens of thousands to millions of dollars, limits accessibility of hyperpolarization for the broad scientific community. In this work, we aim to mitigate some of the challenges by developing a cost-effective solution for parahydrogen (pH2)-based PHIP and SABRE HP methods. A custom coil-winding machine was designed to fabricate solenoid magnet coils, which were then evaluated for their magnetic field profiles, demonstrating a high degree of magnetic field homogeneity. A model 1H SABRE experiment successfully implemented the constructed solenoid, achieving efficient hyperpolarization. Additionally, the solenoid magnet can be utilized for in situ detection of hyperpolarization when integrated with a low-field NMR spectrometer, reducing the total setup cost to a few thousand dollars. These findings suggest that our approach makes HP technology more affordable and accessible, potentially broadening its applications in chemical and biomedical research, as well as educational settings involving undergraduate student researchers. This work provides a practical pathway to lower the financial barriers associated with pH2 HP setups.