Tristan Lemke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tristan Lemke has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Felix Busch
School of Medicine and Health, Department of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, TUM University Hospital, Technical University of Munich, Munich, Germany
4 shared publications - Su Hwan Kim
Department of Diagnostic and Interventional Radiology, TUM University Hospital, School of Medicine and Health, Technical University of Munich, Munich, Germany
4 shared publications - Christian J. Mertens
Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum, Technical University of Munich (TUM), Munich, Germany
3 shared publications - Lisa Christine Adams
Technical University of Munich
3 shared publications - Alexander Wolfgang Marka
Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, 81675 Munich, Germany
2 shared publications Avan Kader
Institute for Diagnostic and Interventional Radiology, TUM School of Medicine and Health, TUM University Hospital Kinikum Rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany
2 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (10) , 7698-7709
TOPOS: target organ prediction on scout views for automated CT scan planning
Background: Overscanning is a common issue in CT planning, leading to unnecessary radiation exposure. Purpose: To develop a deep learning model to segment anatomical structures in scout views to optimize scan ranges and reduce radiation. Materials and methods: In this single-center retrospective study, 1146 patients undergoing CT between 2022 and 2025 were included. The model was trained on segmentations of 26 target structures in five regions (head, neck, chest, chest-to-pelvis, abdomen-to-pelvis), transferred to scout views and manually corrected. Performance was evaluated using the Dice-Sørensen coefficient and normalized surface distance on an internal test set of 100 patients and 36 external chest CTs. Automated versus manual scan planning was compared in 61 internal (chest, upper abdomen, head) and 14 external (chest) CTs, with z-axis coverage and dose-length product. Results: 1146 patients (mean age, 63 ± 17 years; 577 men) were included. For target structures in five regions, mean DSC and NSD were 0.93 and 0.88. External mean DSC across chest targets was 0.851 ± 0.051. Automated planning captured relevant anatomy in 98% of internal and 92.9% of external CTs. Scan length significantly decreased for automated planning in the internal test cohort (chest 50 mm (15%), p < 0.001; upper abdomen 60 mm (25%), p < 0.001; cranial 19 mm (11%), p < 0.001), yielding corresponding DLP reductions of 19%, 25% and 11%, respectively. In the external cohort, scan length decreased by 115 mm (28.7%, p < 0.0001) with a corresponding 28.5% DLP reduction. Conclusion: The proposed model enables reliable automated CT scan planning and reduces overscanning and radiation exposure without compromising diagnostic quality. Key Points: Question Can segmentation of anatomical structures on CT scout views enable automated scan planning to reduce overscanning and unnecessary radiation exposure? Findings A deep learning model segmented planning-relevant anatomy on CT scout views and reduced scan length and dose while preserving anatomical coverage. Clinical relevance Unnecessary radiation from overscanning is a patient safety concern. Automated CT planning with the proposed deep learning model reduces radiation exposure while ensuring full anatomical coverage for the evaluated scan regions. Graphical
- 14 May 2026
- Published by Springer Nature in European Radiology
- Vol. 36 (10) , 7698-7709
Open AccessTOPOS: target organ prediction on scout views for automated CT scan planning
Background: Overscanning is a common issue in CT planning, leading to unnecessary radiation exposure. Purpose: To develop a deep learning model to segment anatomical structures in scout views to optimize scan ranges and reduce radiation. Materials and methods: In this single-center retrospective study, 1146 patients undergoing CT between 2022 and 2025 were included. The model was trained on segmentations of 26 target structures in five regions (head, neck, chest, chest-to-pelvis, abdomen-to-pelvis), transferred to scout views and manually corrected. Performance was evaluated using the Dice-Sørensen coefficient and normalized surface distance on an internal test set of 100 patients and 36 external chest CTs. Automated versus manual scan planning was compared in 61 internal (chest, upper abdomen, head) and 14 external (chest) CTs, with z-axis coverage and dose-length product. Results: 1146 patients (mean age, 63 ± 17 years; 577 men) were included. For target structures in five regions, mean DSC and NSD were 0.93 and 0.88. External mean DSC across chest targets was 0.851 ± 0.051. Automated planning captured relevant anatomy in 98% of internal and 92.9% of external CTs. Scan length significantly decreased for automated planning in the internal test cohort (chest 50 mm (15%), p < 0.001; upper abdomen 60 mm (25%), p < 0.001; cranial 19 mm (11%), p < 0.001), yielding corresponding DLP reductions of 19%, 25% and 11%, respectively. In the external cohort, scan length decreased by 115 mm (28.7%, p < 0.0001) with a corresponding 28.5% DLP reduction. Conclusion: The proposed model enables reliable automated CT scan planning and reduces overscanning and radiation exposure without compromising diagnostic quality. Key Points: Question Can segmentation of anatomical structures on CT scout views enable automated scan planning to reduce overscanning and unnecessary radiation exposure? Findings A deep learning model segmented planning-relevant anatomy on CT scout views and reduced scan length and dose while preserving anatomical coverage. Clinical relevance Unnecessary radiation from overscanning is a patient safety concern. Automated CT planning with the proposed deep learning model reduces radiation exposure while ensuring full anatomical coverage for the evaluated scan regions. Graphical
- 1 May 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 319 (2) , e251347
Associations of MRI-derived Paraspinal IMAT and LMM with Cardiometabolic Risk Factors: Results from a German Cohort
Artificial intelligence–derived muscle composition from whole-body MRI scans identified individuals with cardiometabolic risk factors but no pre-existing conditions in a nationwide population.
- 1 May 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 319 (2) , e251347
Associations of MRI-derived Paraspinal IMAT and LMM with Cardiometabolic Risk Factors: Results from a German Cohort
Artificial intelligence–derived muscle composition from whole-body MRI scans identified individuals with cardiometabolic risk factors but no pre-existing conditions in a nationwide population.
- 1 November 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 317 (2) , e251844
A Prospective Controlled Trial of Large Language Model–based Simplification of Oncologic CT Reports for Patients with Cancer
Large language model–based simplification of oncologic CT reports substantially improved participant comprehension and reduced reading burden but required radiologist oversight because of clinically relevant errors in 3%–7% of simplified reports.
- 1 November 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 317 (2) , e251844
A Prospective Controlled Trial of Large Language Model–based Simplification of Oncologic CT Reports for Patients with Cancer
Large language model–based simplification of oncologic CT reports substantially improved participant comprehension and reduced reading burden but required radiologist oversight because of clinically relevant errors in 3%–7% of simplified reports.
- Open Access
- 8 October 2025
- Published by Elsevier in Radiography
- Vol. 31 (6) , 103189
Evaluation of commercial AI algorithms for the detection of fractures, effusions, and dislocations on real-world clinical data: A prospective registry study
- 8 October 2025
- Published by Elsevier in Radiography
- Vol. 31 (6) , 103189
Open AccessEvaluation of commercial AI algorithms for the detection of fractures, effusions, and dislocations on real-world clinical data: A prospective registry study
- Open Access
- 17 September 2025
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 205, 106120
Real-world clinical impact of three commercial AI algorithms on musculoskeletal radiography interpretation: A prospective crossover reader study
- 17 September 2025
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 205, 106120
Open AccessReal-world clinical impact of three commercial AI algorithms on musculoskeletal radiography interpretation: A prospective crossover reader study