Pavel Strmiska
Pavel Strmiska has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ondrej Cejpek
4 shared publications- Jiri Hajek3 shared publications
- Milan Malý
Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
3 shared publications Frantisek Prinz
2 shared publicationsJan Jedelsky
2 shared publications- Jan Jedelsky
Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Outside-in-gas versus outside-in-liquid effervescent atomizers: internal flow, discharge coefficient and drop size
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by about 4% and D32 by about 12% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.
- 29 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOutside-in-gas versus outside-in-liquid effervescent atomizers: internal flow, discharge coefficient and drop size
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by about 4% and D32 by about 12% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.
- Open Access
- 16 July 2026
- Published by Elsevier in SSRN Electronic Journal
Outside-in-gas versus outside-in-liquid effervescent atomizers: internal flow, discharge coefficient and drop size
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by 3–8% and D32 by 15–24% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.
- 16 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessOutside-in-gas versus outside-in-liquid effervescent atomizers: internal flow, discharge coefficient and drop size
Effervescent atomizers are sensitive to the two-phase flow regime that develops in their mixing chamber, but the link between the regime, discharge stability and drop size is still poorly quantified. The internal flow of a modular transparent atomizer was visualized with a high-speed camera and related the observed regimes to the discharge coefficient (CD) and Sauter mean diameter (D32). The test matrix covered three mixing-chamber diameters (3–12 mm), three exit orifices (0.75–3 mm), seven aerator designs, both outside-in-gas (OIG) and outside-in-liquid (OIL) configurations, gas-to-liquid mass ratios (GLR) of 0.1–10.8% and mixing overpressures of 50–200 kPa. GLR was the strongest predictor of the flow regime; however, bubbly, churn and slug flow coexisted at GLR = 0.1%, while annular flow dominated above 1.2%. Different regimes occurred at nearly identical superficial velocities in the mixing chamber, depending on the aerator and configuration, so published regime maps predicted the transitions only partially. Slug flow raised CD by 3–8% and D32 by 15–24% relative to churn flow at matched conditions, which links the internal flow structure directly to the discharge behaviour. CD decayed logarithmically with GLR rather than following a power law. Distinction between OIL and OIG configurations was observed for CD and D32. Smaller aerator holes improved atomization in OIG but promoted slug flow in OIL; the two configurations therefore need separate design rules.
- Open Access
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
Disturbance Wave and Slug Passage Frequency in Effervescent Atomizers
Effervescent atomizers mix gas and liquid internally at low pressure, advantageous for atomization of viscous and contaminated liquids. Periodic fluctuations in spray cone angle and discharge character limits their practical application. This study systematically investigates instability frequency across 34 atomizer geometries, spanning gas-to-liquid ratios (GLR) of 0.1%-10.8%, mixing overpressures of 50-200 kPa, and both outside-in-liquid (OIL) and outside-in-gas (OIG) configurations. Two instability mechanisms were identified: slug flow at low GLR, where large gas bubbles alternate with liquid plugs producing cyclic jet-and-spray behavior, and disturbance waves in annular flow at higher GLR, where periodic liquid-film thickening generates similar oscillating discharge patterns. Instability frequencies were extracted using three complementary methods applied to high-speed image sequences: spectral proper orthogonal decomposition, and fast Fourier transforms of spray cone angle and flow-regime class data from machine learning segmentation. Results reveal that instability frequency is governed by superficial phase velocities and mixing chamber length, expressed as f = (U g + U l)/L, with distinct coefficients for OIL and OIG configurations. Frequencies of the instability reach values from single Hz to several hundreds, with geometry being the main driving factor influencing the superficial velocity ranges. The length dependence departs from classical two-phase pipe-flow, indicating that disturbance waves and slug flow within the chambers operate under different mechanisms than fully developed pipe flows. The OIG configuration exhibited higher instability frequencies overall, this is attributed to reduced liquid holdup and higher effective liquid velocities. OIG outperformed OIL in spray cone angle variation, with 30-50% lower coefficient of variance.
- 15 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDisturbance Wave and Slug Passage Frequency in Effervescent Atomizers
Effervescent atomizers mix gas and liquid internally at low pressure, advantageous for atomization of viscous and contaminated liquids. Periodic fluctuations in spray cone angle and discharge character limits their practical application. This study systematically investigates instability frequency across 34 atomizer geometries, spanning gas-to-liquid ratios (GLR) of 0.1%-10.8%, mixing overpressures of 50-200 kPa, and both outside-in-liquid (OIL) and outside-in-gas (OIG) configurations. Two instability mechanisms were identified: slug flow at low GLR, where large gas bubbles alternate with liquid plugs producing cyclic jet-and-spray behavior, and disturbance waves in annular flow at higher GLR, where periodic liquid-film thickening generates similar oscillating discharge patterns. Instability frequencies were extracted using three complementary methods applied to high-speed image sequences: spectral proper orthogonal decomposition, and fast Fourier transforms of spray cone angle and flow-regime class data from machine learning segmentation. Results reveal that instability frequency is governed by superficial phase velocities and mixing chamber length, expressed as f = (U g + U l)/L, with distinct coefficients for OIL and OIG configurations. Frequencies of the instability reach values from single Hz to several hundreds, with geometry being the main driving factor influencing the superficial velocity ranges. The length dependence departs from classical two-phase pipe-flow, indicating that disturbance waves and slug flow within the chambers operate under different mechanisms than fully developed pipe flows. The OIG configuration exhibited higher instability frequencies overall, this is attributed to reduced liquid holdup and higher effective liquid velocities. OIG outperformed OIL in spray cone angle variation, with 30-50% lower coefficient of variance.
- Open Access
- 17 September 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 255
Effect of shear-thinning on pressure-swirl atomization
- 17 September 2025
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 255
Open AccessEffect of shear-thinning on pressure-swirl atomization