Yingduo Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yingduo Duan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Honglei Xu
Northwestern Polytechnical University
1 shared publication - Kai Cui
School of Microelectronics, Northwestern Polytechnical University, Xian, China
1 shared publication - Xiaoya Fan
Northwestern Polytechnical University
1 shared publication - Yan Lu
University of Macau
1 shared publication - Yanzhao Ma
Northwestern Polytechnical University
1 shared publication
Latest Publications
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 261-264
A Linear Dynamic Voltage Scaling Technique With Adaptive Minimum Voltage Headroom Tracking for Implantable Neurostimulation
This letter presents a linear dynamic voltage scaling (DVS) technique using a dual-loop multistage charge-pump maintaining the minimum voltage headroom for implantable neurostimulation. By adopting an analog DVS with adaptive feedback divider, the stimulus current source could be always kept operating at the boundary of the saturation region and the linear region under different stimulus currents. Furthermore, a simple mode-switched control is introduced to improve the loop response of charge-pump. The design has been fabricated in a 0.18- $\mu $ m BCD process. The DVS technique increases the measured stimulus efficiency up to 52.8% higher than a fixed supply voltage with a peak efficiency of 89.6% in the range of the stimulus current from 0.5 mA to 0.9 mA.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 261-264
A Linear Dynamic Voltage Scaling Technique With Adaptive Minimum Voltage Headroom Tracking for Implantable Neurostimulation
This letter presents a linear dynamic voltage scaling (DVS) technique using a dual-loop multistage charge-pump maintaining the minimum voltage headroom for implantable neurostimulation. By adopting an analog DVS with adaptive feedback divider, the stimulus current source could be always kept operating at the boundary of the saturation region and the linear region under different stimulus currents. Furthermore, a simple mode-switched control is introduced to improve the loop response of charge-pump. The design has been fabricated in a 0.18- $\mu $ m BCD process. The DVS technique increases the measured stimulus efficiency up to 52.8% higher than a fixed supply voltage with a peak efficiency of 89.6% in the range of the stimulus current from 0.5 mA to 0.9 mA.