Afra Nawar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Afra Nawar has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Omer T. Inan
Georgia Institute of Technology, Atlanta, Georgia, USA
6 shared publications - Farhan N. Rahman
Georgia Institute of Technology, Atlanta, Georgia, USA
5 shared publications - Amit Jasvant Shah
Emory University, Atlanta, Georgia, USA
4 shared publications - Chuoqi Chen
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
4 shared publications - Onur Selim Kilic
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA, USA
3 shared publications - James Douglas Bremner
Emory University School of Medicine
2 shared publications
Latest Publications
- Open Access
- 16 November 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 8 (1) , 1-28
Towards Monitoring Acute Opioid Withdrawal Severity Using a Multimodal Wearable Chest Patch
To enable timely intervention and reduce risk of returning to use in individuals with opioid use disorder (OUD), there is a need to monitor opioid withdrawal severity using physiological biomarkers. However, in the context of opioid withdrawal, prior studies have relied on data recorded in controlled lab settings over short periods of time and have only focused on a limited set of biomarkers. To address these limitations, using multimodal wearable signals, we extracted and characterized 32 cardiorespiratory features from 16 individuals with OUD experiencing varying levels of withdrawal severity over a 7-day period. Across all participants, we found statistically significant ( p < 0.05) differences in six features between high and low withdrawal. For machine learning-based classification of high vs. low withdrawal, we found that performance improved when leveraging respiratory-focused and sex-/BMI-stratified models (highest macro F1 of 0.812). Finally, in 14 out of 16 participants, at least 1 feature statistically significantly ( p < 0.1) tracked changes in withdrawal scores over the 7-day period. Therefore, our analyses of these features uncovered substantial phenotype sensitivity and physiological heterogeneity across the study cohort. These findings underscore the need for phenotype-aware and personalized modeling approaches for continuous, sensor-based monitoring of withdrawal severity in the future.
- 16 November 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 8 (1) , 1-28
Open AccessTowards Monitoring Acute Opioid Withdrawal Severity Using a Multimodal Wearable Chest Patch
To enable timely intervention and reduce risk of returning to use in individuals with opioid use disorder (OUD), there is a need to monitor opioid withdrawal severity using physiological biomarkers. However, in the context of opioid withdrawal, prior studies have relied on data recorded in controlled lab settings over short periods of time and have only focused on a limited set of biomarkers. To address these limitations, using multimodal wearable signals, we extracted and characterized 32 cardiorespiratory features from 16 individuals with OUD experiencing varying levels of withdrawal severity over a 7-day period. Across all participants, we found statistically significant ( p < 0.05) differences in six features between high and low withdrawal. For machine learning-based classification of high vs. low withdrawal, we found that performance improved when leveraging respiratory-focused and sex-/BMI-stratified models (highest macro F1 of 0.812). Finally, in 14 out of 16 participants, at least 1 feature statistically significantly ( p < 0.1) tracked changes in withdrawal scores over the 7-day period. Therefore, our analyses of these features uncovered substantial phenotype sensitivity and physiological heterogeneity across the study cohort. These findings underscore the need for phenotype-aware and personalized modeling approaches for continuous, sensor-based monitoring of withdrawal severity in the future.
- Open Access
- 14 January 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 7 (1) , 1-17
Quantifying the Cardiovascular Response to Mental Stress Using a Compact Multimodal Wearable Sensing Patch
Acute psychological stress has a multifaceted impact on cardiovascular physiology, including increases in chronotropy, inotropy, and vascular tone. Chronic exposure to stress may greatly increase cardiovascular risk. To examine the cardiovascular impact of acute stress comprehensively, new multimodal portable monitoring solutions are needed. We examined the feasibility of using a compact multimodal wearable patch to measure laboratory-based stress-induced cardiovascular responses in a diverse sample with recent myocardial infarction (MI) and healthy participants (N = 37, 28 MI) during a protocol with a public-speaking stressor. Using the electrocardiogram, seismocardiogram, and photoplethysmogram captured from the device, we found several significant (p < 0.05) autonomic changes in the pooled sample suggesting stress activation: increases in heart rate, chest photoplethysmogram amplitude, and perfusion index and decreases in heart rate variability, left ventricular ejection time, pulse arrival time, and pulse transit time. We, thus, demonstrated that a single wearable device can capture stress-induced cardiovascular changes, enabling simultaneous examination of stress-induced inotropic, chronotropic, and vascular effects. This portable, wireless chest patch may be useful in comprehensively and unobtrusively examining stress-induced cardiovascular effects in-lab. Given the public health importance of psychological stress and cardiovascular disease, future studies should assess the device’s full clinical potential in larger groups with longer monitoring periods.
- 14 January 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Computing for Healthcare
- Vol. 7 (1) , 1-17
Open AccessQuantifying the Cardiovascular Response to Mental Stress Using a Compact Multimodal Wearable Sensing Patch
Acute psychological stress has a multifaceted impact on cardiovascular physiology, including increases in chronotropy, inotropy, and vascular tone. Chronic exposure to stress may greatly increase cardiovascular risk. To examine the cardiovascular impact of acute stress comprehensively, new multimodal portable monitoring solutions are needed. We examined the feasibility of using a compact multimodal wearable patch to measure laboratory-based stress-induced cardiovascular responses in a diverse sample with recent myocardial infarction (MI) and healthy participants (N = 37, 28 MI) during a protocol with a public-speaking stressor. Using the electrocardiogram, seismocardiogram, and photoplethysmogram captured from the device, we found several significant (p < 0.05) autonomic changes in the pooled sample suggesting stress activation: increases in heart rate, chest photoplethysmogram amplitude, and perfusion index and decreases in heart rate variability, left ventricular ejection time, pulse arrival time, and pulse transit time. We, thus, demonstrated that a single wearable device can capture stress-induced cardiovascular changes, enabling simultaneous examination of stress-induced inotropic, chronotropic, and vascular effects. This portable, wireless chest patch may be useful in comprehensively and unobtrusively examining stress-induced cardiovascular effects in-lab. Given the public health importance of psychological stress and cardiovascular disease, future studies should assess the device’s full clinical potential in larger groups with longer monitoring periods.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
SCRIBE Design and Validation: Simultaneous Cardiac and Respiratory Impedance Biomarkers with Electromechanics
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (15) , 1
SCRIBE Design and Validation: Simultaneous Cardiac and Respiratory Impedance Biomarkers with Electromechanics
- 15 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 42194-42208
Life-Vest Embedded Ballistocardiogram Measurement System for Underwater Heart Rate and Heart Rate Variability Monitoring
- 15 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 42194-42208
Life-Vest Embedded Ballistocardiogram Measurement System for Underwater Heart Rate and Heart Rate Variability Monitoring
- 12 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (18) , 35447-35459
Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes
At-home cardiovascular monitoring has become widespread with the commercialization of the photoplethysmogram (PPG) in wearable devices. A tremendous opportunity for comprehensive monitoring of chronotropic, inotropic, and vascular characteristics of the cardiovascular system can be unlocked if PPG data are combined with signals of other modalities at the core body. However, little is known about the quality of core-body PPG or its reactivity to environmental conditions. To elucidate core-body PPG signals, we compared the reactivity and quality of sternum and back PPG signals to finger-based PPG in 24 healthy participants during a protocol with posture and breathing changes. We found that the signal quality of core-body PPG was affected by body location, wavelength, LED/photodiode configuration, posture, and breathing pattern. Notably, reflectance-mode red-wavelength core-body quality was less than that of transmittance-mode finger red-wavelength PPG (${p}~\lt 0.05$ ). However, green-wavelength core-body PPG quality was comparable (${p}~\gt 0.05$ , sternum) or significantly greater (${p}~\lt 0.001$ , back). We also found that PPG amplitude reactivity for core-body signals was in accordance with that of the finger (${p}~\gt 0.05$ or${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ ) = sign($\mu _{\text {periphery}}$ )) for posture changes but opposite (${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ )$\neq $ sign($\mu _{\text {periphery}}$ )) or significantly blunted (${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ ) = sign($\mu _{\text {periphery}}$ ), abs($\mu _{\text {core}}$ ) < abs($\mu _{\text {periphery}}$ )) during deep and resistive breathing. We, thus, demonstrate the importance of studying the reactivity of vasculature at different sensor locations, as their reactivity to various provocations is heterogeneous. Our findings can be used to develop improved hardware for sensing core-body PPG and algorithms for interpreting the signals acquired, enabling clinicians to more comprehensively understand patient cardiovascular health.- 12 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (18) , 35447-35459
Elucidating the Reactivity of Reflectance-Based Core-Body Photoplethysmogram to Posture and Respiratory Changes
At-home cardiovascular monitoring has become widespread with the commercialization of the photoplethysmogram (PPG) in wearable devices. A tremendous opportunity for comprehensive monitoring of chronotropic, inotropic, and vascular characteristics of the cardiovascular system can be unlocked if PPG data are combined with signals of other modalities at the core body. However, little is known about the quality of core-body PPG or its reactivity to environmental conditions. To elucidate core-body PPG signals, we compared the reactivity and quality of sternum and back PPG signals to finger-based PPG in 24 healthy participants during a protocol with posture and breathing changes. We found that the signal quality of core-body PPG was affected by body location, wavelength, LED/photodiode configuration, posture, and breathing pattern. Notably, reflectance-mode red-wavelength core-body quality was less than that of transmittance-mode finger red-wavelength PPG (${p}~\lt 0.05$ ). However, green-wavelength core-body PPG quality was comparable (${p}~\gt 0.05$ , sternum) or significantly greater (${p}~\lt 0.001$ , back). We also found that PPG amplitude reactivity for core-body signals was in accordance with that of the finger (${p}~\gt 0.05$ or${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ ) = sign($\mu _{\text {periphery}}$ )) for posture changes but opposite (${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ )$\neq $ sign($\mu _{\text {periphery}}$ )) or significantly blunted (${p}~\lt 0.05$ , sign($\mu _{\text {core}}$ ) = sign($\mu _{\text {periphery}}$ ), abs($\mu _{\text {core}}$ ) < abs($\mu _{\text {periphery}}$ )) during deep and resistive breathing. We, thus, demonstrate the importance of studying the reactivity of vasculature at different sensor locations, as their reactivity to various provocations is heterogeneous. Our findings can be used to develop improved hardware for sensing core-body PPG and algorithms for interpreting the signals acquired, enabling clinicians to more comprehensively understand patient cardiovascular health.- 19 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110480
Heart rate informed detection of cardiac events using the Kalman filter
- 19 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 195, 110480
Heart rate informed detection of cardiac events using the Kalman filter