T. D. Mamedova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
T. D. Mamedova has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Gennadiy G. Khubulava
Military Medical Academy
2 shared publications - A. A. Kojdan
Pavlov University
1 shared publication - A. B. Sazonov
Military Medical Academy
1 shared publication - A. V. Kriventsov
Military Medical Academy
1 shared publication - Aleksey Borisovich Naumov
Saint-Petersburg State Pediatric Medical University
1 shared publication - Ekaterina V. Mikhailova
Saint-Petersburg State Pediatric Medical University
1 shared publication
Latest Publications
- 12 January 2026
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (4)
Experience in using a cell-free vascular matrix in smalldiameter arterial surgery
Introduction . Modern vascular surgery faces a need for reliable biocompatible models for small-diameter vessel prosthetics, as traditional methods are limited due to donor material shortages and risks of complications such as thrombosis and infection. In this context, the use of prostheses made from decellularized aorta (DCA) – a natural biological scaffold preserving the extracellular matrix that stimulates vascular wall regeneration – is studied. Aim: To evaluate the manufacturability and biocompatibility of DCA prostheses made from rat aorta, when transplanted into the abdominal aorta of animals, with investigation of patency and vascular wall response over 4 weeks. Material and Methods . Chemical and physical decellularization of the aorta using SDS, Triton X-100, and enzymes was performed; prostheses were implanted into 20 Wistar rats. Patency was assessed immediately and 30 minutes post-operation, with morphological control including ultrasound with Doppler performed at 4 weeks. Histological analysis used cross-sections stained with hematoxylin and eosin. Results. Prosthesis transplantation occurred without technical complications. The DCA showed sufficient strength and elasticity. After 4 weeks, normal capillary perfusion in hind limb tissues was noted. Doppler imaging revealed a decrease in mean linear blood flow velocity (about 25%, p < 0.001) in the prosthesis region. Thrombosis or stenosis developed in 60% of animals, aneurysms in 30%. Histology revealed lymphocytic infiltration and intimal hyperplasia in most animals, explaining impaired vessel patency. Conclusion. Decellularized aortic prostheses demonstrate unique biocompatibility and structural similarity to native vessels but carry a high risk of complications such as thrombosis, stenosis, and aneurysms. Modifications, possibly including synthetic coatings or endothelial cell cultivation, are needed to improve stability and thromboresistance.
- 12 January 2026
- Published by Cardiology Research Institute in Siberian Journal of Clinical and Experimental Medicine
- Vol. 40 (4)
Experience in using a cell-free vascular matrix in smalldiameter arterial surgery
Introduction . Modern vascular surgery faces a need for reliable biocompatible models for small-diameter vessel prosthetics, as traditional methods are limited due to donor material shortages and risks of complications such as thrombosis and infection. In this context, the use of prostheses made from decellularized aorta (DCA) – a natural biological scaffold preserving the extracellular matrix that stimulates vascular wall regeneration – is studied. Aim: To evaluate the manufacturability and biocompatibility of DCA prostheses made from rat aorta, when transplanted into the abdominal aorta of animals, with investigation of patency and vascular wall response over 4 weeks. Material and Methods . Chemical and physical decellularization of the aorta using SDS, Triton X-100, and enzymes was performed; prostheses were implanted into 20 Wistar rats. Patency was assessed immediately and 30 minutes post-operation, with morphological control including ultrasound with Doppler performed at 4 weeks. Histological analysis used cross-sections stained with hematoxylin and eosin. Results. Prosthesis transplantation occurred without technical complications. The DCA showed sufficient strength and elasticity. After 4 weeks, normal capillary perfusion in hind limb tissues was noted. Doppler imaging revealed a decrease in mean linear blood flow velocity (about 25%, p < 0.001) in the prosthesis region. Thrombosis or stenosis developed in 60% of animals, aneurysms in 30%. Histology revealed lymphocytic infiltration and intimal hyperplasia in most animals, explaining impaired vessel patency. Conclusion. Decellularized aortic prostheses demonstrate unique biocompatibility and structural similarity to native vessels but carry a high risk of complications such as thrombosis, stenosis, and aneurysms. Modifications, possibly including synthetic coatings or endothelial cell cultivation, are needed to improve stability and thromboresistance.
- Open Access
- 9 August 2025
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Grekov's Bulletin of Surgery
- Vol. 184 (3) , 16-24
Prevention and approaches to bleeding control during ascending aorta replacement
Introduction. Bleeding is an extremely urgent problem in aortic surgery, where its frequency and significance are greater than in other cardiac operations. Among the measures to prevent bleeding, surgical technique plays a fundamental role, especially the methods of forming the anastomosis with the aorta to ensure its tightness. The scientific literature presents many technical modifications of aortic anastomoses, but there are currently no large comparative studies with a high degree of evidence.The objective of this study was to evaluate the efficiency of the protocol of intraoperative support and control of surgical hemostasis, which describes the principles of surgical technique when performing interventions on the aorta, the technique of forming anastomoses and methods of staged control of hemostasis stability during ascending aorta replacement.Methods and materials. Patients who underwent ascending aorta replacement were divided into two groups. The group where the above protocol was used (n=24) and the group with the standard surgical technique (n=19). These groups were compared with each other by the following parameters: bleeding frequency, blood loss volume, frequency of resternotomies, volume of transfused blood components, treatment duration, complication and mortality rate.Results. Statistically significant differences (pConclusions. The protocol of intraoperative support and control of surgical hemostasis is an effective approach to prevent bleeding during ascending aorta replacement.
- 9 August 2025
- Published by FSBEI HE I.P. Pavlov SPbSMU MOH Russia in Grekov's Bulletin of Surgery
- Vol. 184 (3) , 16-24
Open AccessPrevention and approaches to bleeding control during ascending aorta replacement
Introduction. Bleeding is an extremely urgent problem in aortic surgery, where its frequency and significance are greater than in other cardiac operations. Among the measures to prevent bleeding, surgical technique plays a fundamental role, especially the methods of forming the anastomosis with the aorta to ensure its tightness. The scientific literature presents many technical modifications of aortic anastomoses, but there are currently no large comparative studies with a high degree of evidence.The objective of this study was to evaluate the efficiency of the protocol of intraoperative support and control of surgical hemostasis, which describes the principles of surgical technique when performing interventions on the aorta, the technique of forming anastomoses and methods of staged control of hemostasis stability during ascending aorta replacement.Methods and materials. Patients who underwent ascending aorta replacement were divided into two groups. The group where the above protocol was used (n=24) and the group with the standard surgical technique (n=19). These groups were compared with each other by the following parameters: bleeding frequency, blood loss volume, frequency of resternotomies, volume of transfused blood components, treatment duration, complication and mortality rate.Results. Statistically significant differences (pConclusions. The protocol of intraoperative support and control of surgical hemostasis is an effective approach to prevent bleeding during ascending aorta replacement.