Alexandra-Constanța Dudu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandra-Constanța Dudu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Andrei Gabriel Dragos
National Research and Development Institute for Marine Geology and Geoecology 23-25 Dimitrie Onciul Street 024053 GeoEcoMar Bucharest Romania Romania
3 shared publications - Constantin-Ștefan Sava
1 National Institute for Research and Development on Marine Geology and Geo-ecology – GeoEcoMar, Bucharest, Romania
3 shared publications - Corina Avram
National Research and Development Institute for Marine Geology and Geoecology 23-25 Dimitrie Onciul Street 024053 GeoEcoMar Bucharest Romania Romania
3 shared publications - Gabriel Iordache
National Research and Development Institute for Marine Geology and Geoecology 23-25 Dimitrie Onciul Street 024053 GeoEcoMar Bucharest Romania Romania
3 shared publications - Lia Stelea
National Research and Development Institute for Marine Geology and Geoecology 23-25 Dimitrie Onciul Street 024053 GeoEcoMar Bucharest Romania Romania
3 shared publications - Bogdan Baraitareanu
National Research and Development Institute for Marine Geology and Geoecology 23-25 Dimitrie Onciul Street 024053 GeoEcoMar Bucharest Romania Romania
2 shared publications
Latest Publications
- Open Access
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 3 (2)
Rezistivity Survey and Soil Flux Measurements in an Area with Natural CO2 Emissions
In monitoring CO₂ storage sites, it is assumed that detectable variations in electrical resistivity exist in the monitoring area, as CO₂ has a significantly higher resistivity compared to the fluids in the reservoir’s pores. Geophysical methods, particularly geoelectric ones, have been successfully applied to obtain detailed images of a wide range of geological structures, including the heterogeneity of aquifer lithology, aquifer layer thickness, the presence of shale lenses, the position of the hydrostatic level, the identification of fractures and cracks, as well as the characteristics of contamination plumes with inorganic and organic compounds. In this context, vertical electrical sounding (VES) is a near-surface geophysical method, aiming to determine the resistivity distribution with depth and at the surface. Complementary to the monitoring methods for the Băile Lăzărești site (Romania), electrical resistivity measurements – electrometry – were carried out to highlight water bodies near the surface, their regional extent, local geological characteristics, and potential gas migration pathways to the surface, by outlining resistivity anomalies. The method implemented was vertical electrical sounding (VES) – Schlumberger device (MiniSting R1) on 12 profiles (6 profiles from the 12 in the high CO₂ emission area in the northern part of the Lăzărești site, and 6 profiles in the low CO₂ emission area in the southern part of the site). For each of the 6 profiles measured in the high CO₂ emission area, 6 VES measurements were made, with 9 measurements each (a total of 54 resistivity values acquired for each profile). The distance between the current electrodes (AB) was 4, 6, 8, 10, 12, 14, 16, 18, and 20 meters, while the MN distance remained constant at 2 meters. Due to the physical-chemical properties of the soil (alternating shale, marl, and sandstone from the Cretaceous flysch), the maximum penetration depth was calculated at 4.20 meters. The length of the 6 profiles is 30 meters. The geoelectrical investigation revealed that the presence of shale content tends to reduce the increase in resistivity caused by the replacement of water with less conductive CO₂. The obtained results represent one important step to demonstrate the feasibility of using resistivity surveys for monitoring CO2 geological storage sites.
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 3 (2)
Open AccessRezistivity Survey and Soil Flux Measurements in an Area with Natural CO2 Emissions
In monitoring CO₂ storage sites, it is assumed that detectable variations in electrical resistivity exist in the monitoring area, as CO₂ has a significantly higher resistivity compared to the fluids in the reservoir’s pores. Geophysical methods, particularly geoelectric ones, have been successfully applied to obtain detailed images of a wide range of geological structures, including the heterogeneity of aquifer lithology, aquifer layer thickness, the presence of shale lenses, the position of the hydrostatic level, the identification of fractures and cracks, as well as the characteristics of contamination plumes with inorganic and organic compounds. In this context, vertical electrical sounding (VES) is a near-surface geophysical method, aiming to determine the resistivity distribution with depth and at the surface. Complementary to the monitoring methods for the Băile Lăzărești site (Romania), electrical resistivity measurements – electrometry – were carried out to highlight water bodies near the surface, their regional extent, local geological characteristics, and potential gas migration pathways to the surface, by outlining resistivity anomalies. The method implemented was vertical electrical sounding (VES) – Schlumberger device (MiniSting R1) on 12 profiles (6 profiles from the 12 in the high CO₂ emission area in the northern part of the Lăzărești site, and 6 profiles in the low CO₂ emission area in the southern part of the site). For each of the 6 profiles measured in the high CO₂ emission area, 6 VES measurements were made, with 9 measurements each (a total of 54 resistivity values acquired for each profile). The distance between the current electrodes (AB) was 4, 6, 8, 10, 12, 14, 16, 18, and 20 meters, while the MN distance remained constant at 2 meters. Due to the physical-chemical properties of the soil (alternating shale, marl, and sandstone from the Cretaceous flysch), the maximum penetration depth was calculated at 4.20 meters. The length of the 6 profiles is 30 meters. The geoelectrical investigation revealed that the presence of shale content tends to reduce the increase in resistivity caused by the replacement of water with less conductive CO₂. The obtained results represent one important step to demonstrate the feasibility of using resistivity surveys for monitoring CO2 geological storage sites.
- Open Access
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 3 (2)
An Assessment of Topographic and Morphodynamic Features of Borviz Valley, Bodoc Locality, Transylvania Using Photogrammetry
Photogrammetry is a specialized technique essential for acquiring high - resolution 2D and 3D spatial data in a non - invasive manner. Its applications are particularly significant in terrain mapping and topographic analysis, where it serves as a complementary tool for geophysical and geological surveys. Additionally, photogrammetric data play a crucial role in monitoring landslides and erosion, particularly in valley - dominated landscapes, as exemplified in this study. Furthermore, photogrammetry is widely utilized in flood risk assessment and mitigation, as well as in infrastructure planning and land use management, contributing to more informed decision - making in environmental and engineering contexts. In this study, we conducted a survey over an 83,000 - square - meter area situated in Borviz Valley ( that serves as a tributary to the Olt River ) , within Bodoc locality, in the historical region of Transylvania, Romania. The aerial photogrammetric data acquisition was carried out using a DJI Phantom 4 Pro V2.0 UAV system, supplemented by a Trimble R2 GNSS system and a network of nine ground control points (GCPs) to enhance geospatial accuracy. The dataset, consisting of 436 images, was processed using specialized photogrammetric software, such as Agisoft Metashape, along with various Topographic and GIS tools, including ESRI ArcGIS and Blue Marble Geographics Global Mapper. This processing workflow resulted in high - resolution 3D models and 2D maps, represented by a range of photogrammetric products, including Digital Elevation Models (DEMs), Digital Terrain Models (DTMs), classified point clouds, and orthophotos (orthomosaics). By generating classified elevation models that include only the terrain class while excluding vegetation, built structures, and other anthropogenic objects, we obtained a more detailed representation of the ground surface, allowing for a more accurate depiction of the valley’s morphological characteristics. Furthermore, the orthophoto (orthomosaic), produced by integrating all photographic images acquired during the photogrammetric survey, provides a highly precise geospatial reference. This dataset can serve as a valuable resource for future survey planning across various domains such as topography, civil engineering, general infrastructure, utility construction, etc.
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 3 (2)
Open AccessAn Assessment of Topographic and Morphodynamic Features of Borviz Valley, Bodoc Locality, Transylvania Using Photogrammetry
Photogrammetry is a specialized technique essential for acquiring high - resolution 2D and 3D spatial data in a non - invasive manner. Its applications are particularly significant in terrain mapping and topographic analysis, where it serves as a complementary tool for geophysical and geological surveys. Additionally, photogrammetric data play a crucial role in monitoring landslides and erosion, particularly in valley - dominated landscapes, as exemplified in this study. Furthermore, photogrammetry is widely utilized in flood risk assessment and mitigation, as well as in infrastructure planning and land use management, contributing to more informed decision - making in environmental and engineering contexts. In this study, we conducted a survey over an 83,000 - square - meter area situated in Borviz Valley ( that serves as a tributary to the Olt River ) , within Bodoc locality, in the historical region of Transylvania, Romania. The aerial photogrammetric data acquisition was carried out using a DJI Phantom 4 Pro V2.0 UAV system, supplemented by a Trimble R2 GNSS system and a network of nine ground control points (GCPs) to enhance geospatial accuracy. The dataset, consisting of 436 images, was processed using specialized photogrammetric software, such as Agisoft Metashape, along with various Topographic and GIS tools, including ESRI ArcGIS and Blue Marble Geographics Global Mapper. This processing workflow resulted in high - resolution 3D models and 2D maps, represented by a range of photogrammetric products, including Digital Elevation Models (DEMs), Digital Terrain Models (DTMs), classified point clouds, and orthophotos (orthomosaics). By generating classified elevation models that include only the terrain class while excluding vegetation, built structures, and other anthropogenic objects, we obtained a more detailed representation of the ground surface, allowing for a more accurate depiction of the valley’s morphological characteristics. Furthermore, the orthophoto (orthomosaic), produced by integrating all photographic images acquired during the photogrammetric survey, provides a highly precise geospatial reference. This dataset can serve as a valuable resource for future survey planning across various domains such as topography, civil engineering, general infrastructure, utility construction, etc.
- Open Access
- 25 September 2025
- Published by MDPI AG in Environments
- Vol. 12 (10) , 344
DNA Metabarcoding of Soil Microbial Communities in a Postvolcanic Region: Case Study from Băile Lăzărești, Romania
This study investigates the impact of post-volcanic gas emissions on soil microbial communities in the Băile Lăzărești region (Romania). Nineteen soil samples across a CO2 gradient ranging from background levels to ≈46,221 ppm. Methane and hydrogen sulfide showed localized peaks (CH4 up to 8271 ppm; H2S up to ~10.12 ppm), with CH4 contributing to outlier community patterns. eDNA metabarcoding identified 3064 OTUs, (2463 bacterial and 601 fungal). Bacteria were dominated by Proteobacteria, fungi by Ascomycota, with Thelebolales nearly ubiquitous. Alpha diversity (Chao1, Fisher) declined significantly in high-CO2 soils (>3000 ppm), while intermediate concentrations (1000–3000 ppm) showed heterogeneous responses. Beta-diversity analyses (PCoA, clustering) revealed distinct grouping of high-CO2 soils, with sample P16 (CH4-rich) forming an outlier. A PCA including CO2, CH4, and H2S confirmed CO2 as the main driver of variance (>65%), with CH4 accounting for local effects. At the genus level, Acidobacterium, Granulicella, Streptomyces, and Nocardia increased with CO2, while Rhizobium and Pseudomonas declined. Fungal responses were mixed: Thelebolus and Cladosporium increased, whereas Mortierella and Cryptococcus decreased. Overall, elevated soil CO2 reduced microbial richness and reorganized communities, while CH4 shaped local niches. These findings provide key natural analog insights for assessing ecological risks of CO2 leakage from geological storage.
- 25 September 2025
- Published by MDPI AG in Environments
- Vol. 12 (10) , 344
Open AccessDNA Metabarcoding of Soil Microbial Communities in a Postvolcanic Region: Case Study from Băile Lăzărești, Romania
This study investigates the impact of post-volcanic gas emissions on soil microbial communities in the Băile Lăzărești region (Romania). Nineteen soil samples across a CO2 gradient ranging from background levels to ≈46,221 ppm. Methane and hydrogen sulfide showed localized peaks (CH4 up to 8271 ppm; H2S up to ~10.12 ppm), with CH4 contributing to outlier community patterns. eDNA metabarcoding identified 3064 OTUs, (2463 bacterial and 601 fungal). Bacteria were dominated by Proteobacteria, fungi by Ascomycota, with Thelebolales nearly ubiquitous. Alpha diversity (Chao1, Fisher) declined significantly in high-CO2 soils (>3000 ppm), while intermediate concentrations (1000–3000 ppm) showed heterogeneous responses. Beta-diversity analyses (PCoA, clustering) revealed distinct grouping of high-CO2 soils, with sample P16 (CH4-rich) forming an outlier. A PCA including CO2, CH4, and H2S confirmed CO2 as the main driver of variance (>65%), with CH4 accounting for local effects. At the genus level, Acidobacterium, Granulicella, Streptomyces, and Nocardia increased with CO2, while Rhizobium and Pseudomonas declined. Fungal responses were mixed: Thelebolus and Cladosporium increased, whereas Mortierella and Cryptococcus decreased. Overall, elevated soil CO2 reduced microbial richness and reorganized communities, while CH4 shaped local niches. These findings provide key natural analog insights for assessing ecological risks of CO2 leakage from geological storage.
- Open Access
- 25 September 2023
- Published by Babes-Bolyai University Cluj-Napoca in Studia Universitatis Babeș-Bolyai Chemia
- Vol. 68 (3) , 51-70
COMPARISON OF MEMBRANE-BASED PRE-AND POST-COMBUSTION CO2 CAPTURE OPTIONS APPLIED IN ENERGY-INTENSIVE INDUSTRIAL APPLICATIONS
Deployment of decarbonization technologies in energy-intensive industrial applications (e.g., heat and power, metallurgy, cement, chemical sectors etc.) is of great importance for reducing CO2 emission and achieving global climate neutrality. Membrane CO2 removal systems gained relevant attention as possible energy and cost-efficient CO2 capture technology. This paper is evaluating membrane-based pre- and post-combustion CO2 capture to be applied in various industrial applications with high fossil CO2 emissions. The evaluation was geared mainly towards quantification of ancillary energy consumptions of membrane systems as well as the specification of captured CO2 in respect to its potential utilization and storage applications. As the assessment show, the membrane-based systems are promising CO2 capture technology for both pre- and post-combustion capture configurations.
- 25 September 2023
- Published by Babes-Bolyai University Cluj-Napoca in Studia Universitatis Babeș-Bolyai Chemia
- Vol. 68 (3) , 51-70
Open AccessCOMPARISON OF MEMBRANE-BASED PRE-AND POST-COMBUSTION CO2 CAPTURE OPTIONS APPLIED IN ENERGY-INTENSIVE INDUSTRIAL APPLICATIONS
Deployment of decarbonization technologies in energy-intensive industrial applications (e.g., heat and power, metallurgy, cement, chemical sectors etc.) is of great importance for reducing CO2 emission and achieving global climate neutrality. Membrane CO2 removal systems gained relevant attention as possible energy and cost-efficient CO2 capture technology. This paper is evaluating membrane-based pre- and post-combustion CO2 capture to be applied in various industrial applications with high fossil CO2 emissions. The evaluation was geared mainly towards quantification of ancillary energy consumptions of membrane systems as well as the specification of captured CO2 in respect to its potential utilization and storage applications. As the assessment show, the membrane-based systems are promising CO2 capture technology for both pre- and post-combustion capture configurations.