Heather Ralston
Heather Ralston has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adrian Butterworth
Microplate Dx, Thomas Graham Building, 295 Cathedral Street, Glasgow G1 1XL, U.K.
2 shared publications - Damion K. Corrigan
University of Strathclyde
2 shared publications - Paul A. Hoskisson
Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, G4 0RE, UK
2 shared publications Alistair Longmuir
Microplate Dx, Thomas Graham Building, 295 Cathedral Street, Glasgow G1 1XL, U.K.
1 shared publication- Alistair Longmuir
MicroplateDx
1 shared publication Amanda Winter
The Newcastle upon Tyne Hospitals NHS Foundation Trust
1 shared publication
Latest Publications
- Open Access
- 13 February 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (2) , 1041-1049
Toward Enhanced Selection of Antibiotics in a Hospital Laboratory—Development of a Rapid Electrochemical Antimicrobial Sensitivity Test for Urinary Tract Infections
Antimicrobial resistance poses a major global health threat, often driven by empirical antibiotic use due to the relatively slow (24-72 h) diagnostic pathway for urinary tract infections (UTIs). Due to their low cost and ease of multiplexing, electrochemical biosensors offer a promising alternative. Herein, we report on the Microplate Dx RapidPlate platform, a rapid electrochemical impedance spectroscopy (EIS)-based approach for accelerated antibiotic susceptibility testing (AST) directly from urine samples, without pre-treatment. This report charts the evolution of the core EIS-based AST measurement from a laboratory prototype into a fully realized Alpha prototype platform with an accompanying 32-channel electrochemical cartridge designed specifically for interrogation of urine samples. A total of 89 clinically derived urine samples were evaluated at three clinical sites (U.K. and India), with results compared against standard methods (VITEK 2 and disk diffusion). The impedance-based RapidPlate system detected bacterial growth within 50 min and provided susceptibility profiles by 85 min, with 95% concordance to reference tests. Consistent performance was demonstrated across diverse clinical settings and organisms, including Escherichia coli and Klebsiella pneumoniae. The RapidPlate AST system has demonstrated great potential as a cost-effective, point-of-care tool for rapid AST, supporting and improving UTI management and antimicrobial stewardship.
- 13 February 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (2) , 1041-1049
Open AccessToward Enhanced Selection of Antibiotics in a Hospital Laboratory—Development of a Rapid Electrochemical Antimicrobial Sensitivity Test for Urinary Tract Infections
Antimicrobial resistance poses a major global health threat, often driven by empirical antibiotic use due to the relatively slow (24-72 h) diagnostic pathway for urinary tract infections (UTIs). Due to their low cost and ease of multiplexing, electrochemical biosensors offer a promising alternative. Herein, we report on the Microplate Dx RapidPlate platform, a rapid electrochemical impedance spectroscopy (EIS)-based approach for accelerated antibiotic susceptibility testing (AST) directly from urine samples, without pre-treatment. This report charts the evolution of the core EIS-based AST measurement from a laboratory prototype into a fully realized Alpha prototype platform with an accompanying 32-channel electrochemical cartridge designed specifically for interrogation of urine samples. A total of 89 clinically derived urine samples were evaluated at three clinical sites (U.K. and India), with results compared against standard methods (VITEK 2 and disk diffusion). The impedance-based RapidPlate system detected bacterial growth within 50 min and provided susceptibility profiles by 85 min, with 95% concordance to reference tests. Consistent performance was demonstrated across diverse clinical settings and organisms, including Escherichia coli and Klebsiella pneumoniae. The RapidPlate AST system has demonstrated great potential as a cost-effective, point-of-care tool for rapid AST, supporting and improving UTI management and antimicrobial stewardship.
- Open Access
- 29 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Towards enhanced selection of antibiotics in a hospital laboratory – development of a rapid electrochemical-based antimicrobial sensitivity test for Urinary Tract Infections.
Antimicrobial resistance (AMR) poses a major global health threat, often driven by empirical antibiotic use due to the relatively slow (24-72 hour) diagnostic pathway for urinary tract infections (UTIs). Due to their low cost and ease of multiplexing, electro-chemical biosensors offer a promising alternative. Herein, we report on the Microplate Dx RapidPlate™ platform, a rapid electrochemical impedance spectroscopy (EIS) based approach for accelerated antibiotic susceptibility testing (AST) directly from urine samples, without pre-treatment. This report charts the evolution of the core EIS based AST measurement from laboratory proto-type into fully realised Alpha prototype platform with an accompanying 32-channel electrochemical cartridge designed specifically for interrogation of urine samples. A total of 89 clinically derived urine samples were evaluated at three clinical sites (UK and India), with results compared against standard methods (VITEK 2 and disk diffusion). The impedance based RapidPlate™ system detected bacterial growth within 50 minutes and provided susceptibility profiles by 85 minutes, with 94% concordance to reference tests. Consistent performance is demonstrated across diverse clinical settings and organisms, including Escherichia coli and Klebsiella pneumoniae. The RapidPlate™ AST system has demonstrated great potential as a cost-effective, point-of-care tool for rapid AST, supporting and improving UTI management and antimicrobial stewardship.
- 29 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTowards enhanced selection of antibiotics in a hospital laboratory – development of a rapid electrochemical-based antimicrobial sensitivity test for Urinary Tract Infections.
Antimicrobial resistance (AMR) poses a major global health threat, often driven by empirical antibiotic use due to the relatively slow (24-72 hour) diagnostic pathway for urinary tract infections (UTIs). Due to their low cost and ease of multiplexing, electro-chemical biosensors offer a promising alternative. Herein, we report on the Microplate Dx RapidPlate™ platform, a rapid electrochemical impedance spectroscopy (EIS) based approach for accelerated antibiotic susceptibility testing (AST) directly from urine samples, without pre-treatment. This report charts the evolution of the core EIS based AST measurement from laboratory proto-type into fully realised Alpha prototype platform with an accompanying 32-channel electrochemical cartridge designed specifically for interrogation of urine samples. A total of 89 clinically derived urine samples were evaluated at three clinical sites (UK and India), with results compared against standard methods (VITEK 2 and disk diffusion). The impedance based RapidPlate™ system detected bacterial growth within 50 minutes and provided susceptibility profiles by 85 minutes, with 94% concordance to reference tests. Consistent performance is demonstrated across diverse clinical settings and organisms, including Escherichia coli and Klebsiella pneumoniae. The RapidPlate™ AST system has demonstrated great potential as a cost-effective, point-of-care tool for rapid AST, supporting and improving UTI management and antimicrobial stewardship.