YGYu Guo

Yu Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yu Guo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Unified Framework for Indirect Measurement of Human Ground Reaction Forces from Kinematics under Varying Contact Topologies

    by Jingtao Li, Jiale Ge, Yu Guo, Jingke Song, Yang Sun, Yuan Gao, Tieshi Zhao

    Contact force identification under complex and varying contact conditions is a key problem in multibody system dynamics, with human ground reaction force (GRF) estimation being one of the most representative applications. However, conventional force plates are spatially constrained and cannot provide continuous measurements under complex locomotion conditions. To address this issue, this study proposes a physics-consistent inverse dynamics framework for human motion across diverse locomotion conditions, enabling indirect GRF estimation from kinematic measurements. The human body is modeled as an open-chain multibody system with 18 rigid bodies and 33 degrees of freedom. A unified global dynamic equilibrium is established using screw theory and d'Alembert's principle. Physical constraints based on the continuous evolution of the center of pressure and the attenuation characteristics of the ground reaction moment are introduced to resolve the statically indeterminate contact-force distribution during double support, yielding a unique minimum-norm solution via least squares without requiring force-plate data or predefined motion patterns. Experimental results from level walking and stair ascent demonstrate high agreement between the reconstructed GRFs and force-plate measurements. Furthermore, vertical GRF and CoP time-series signals were reconstructed for five representative locomotion modes using publicly available human kinematic data, achieving an independent-test classification accuracy of 84.69% in gait recognition. These results demonstrate that the reconstructed signals effectively preserve locomotion-related dynamic information and generalize well across different locomotion modes. The proposed framework provides a physically consistent and scalable approach for the indirect measurement of external loads under complex contact conditions.

  • Image Feature Points-Driven Online Calibration Method for Monocular 1-D Galvanometer Systems

    by Jianxin Liu, Yu Guo, Chen Zhao, Ziming Chen, Yanwen Li

    Monocular one-dimensional galvanometer scanning systems have been widely used in the field of non-contact 3D scanning. However, this system has extremely high requirements for the temporal synchronization between motor control and camera acquisition, as well as the assembly accuracy of the mechanical structure. This paper proposes an online calibration method driven by image feature point data: by introducing an auxiliary structured light system, the intersection points of the Auxiliary Structured Light (ASL) and Measurement Structured Light (MSL) are used as the feature points input to the system, and a residual neural network (ResNet) is employed to realize the mapping process from feature point data to the MSL light plane normal vector. The acquisition of driving data required for the MSL calibration model and the measurement process are completely synchronized on the time axis, which avoids the problem of requiring synchronization between image and encoder data acquisition, and bypasses the rotation axis calibration process in the traditional physical model. In addition, based on the invariance of projective lines, this paper also proposes a dataset construction method and a two-stage training method suitable for this system. This dataset construction method can simplify the acquisition process of data required for neural network training, and the two-stage training mode can suppress the overfitting phenomenon during the training process and improve the generalization ability of the network. Experiments show that the diameter fitting error of the 3D reconstruction of the target sphere by this system is less than 40 μm.

  • Design and analysis of an adaptive cable-driven knee unloading exoskeleton based on a rhombus linkage mechanism

    by Yu Guo, Xiao Yang, Ziming Chen, Xiangyu Yan, Fei Liu

    Biomechanical intervention on lower limb joints using exoskeletons to reduce joint loads and provide walking assistance has become a research hotspot in the fields of rehabilitation and elderly care. To address the challenges of human-exoskeleton (H-E) kinematic compatibility and knee joint unloading demands, this study proposes a novel rhombus linkage exoskeleton mechanism capable of adaptive knee motion without requiring precise alignment with the human knee axis. The exoskeleton is driven by a Bowden cable system to provide thigh support, thereby achieving effective knee joint unloading. Based on the screw theory, the degrees of freedom (DOF) of the exoskeleton mechanism (DOF = 3) and the H-E closed-loop mechanism (DOF = 1) were analyzed, and the kinematic model of the exoskeleton and the H-E closed-loop kinematic model were established, respectively. A mechanical model of the driving system was developed, and a simulation was conducted to validate the accuracy of the model. The output characteristics of the cable-driven system were investigated under varying bending angles and bending times. A prototype was fabricated and tested in wearable scenarios. The experimental results demonstrate that the exoskeleton system exhibits excellent biocompatibility and weight-bearing support capability. Compatibility tests confirm that the exoskeleton does not interfere with human motion. Through human-in-the-loop optimization, the optimal Bowden cable output force profile was obtained, which minimizes gait impact while achieving a peak support force of 195.8 N . Further validation from wear trials with five subjects confirms the system’s low interference with natural human motion (maximum lower-limb joint angle deviation of only $8^\circ$ ).