Qingtian Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qingtian Su has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Changze Xu
Shandong Provincial Communications Planning and Design Institute Group Co., Ltd., Jinan 250031, China
1 shared publication - Chong Shen
Department of Bridge Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Fawas. O. Matanmi
Department of Bridge Engineering, Tongji University, 1239 Siping Road, Shanghai 200092, China
1 shared publication - Hai Yan
Shanghai Municipal Engineering Design Institute (Group) Co., Ltd., Shanghai 200092, China
1 shared publication - Haowen Zheng
Department of Bridge Engineering, Tongji University, Shanghai 200092, China
1 shared publication - Rui Zhao
Department of Bridge Engineering, Tongji University, Shanghai 200092, China
1 shared publication
Latest Publications
- Open Access
Global Structural Performance and Repeated-Loading Effects of Steel–Concrete Composite Bridge Decks with Permanent Flat Steel Bottom Formwork
This study investigates the structural role of permanent flat steel bottom formwork in steel–concrete composite bridge decks from construction to long-term service through global numerical analysis and full-scale testing. A three-dimensional finite element model of a 3 × 40 m continuous composite girder bridge of the Beijing-Taipei (Jingtai) Expressway expansion project compared girders with and without the formwork during girder erection, concrete casting, secondary dead loading, and vehicle loading; a full-scale two-span specimen was tested under staged static loading, 2 million load cycles, and a failure test. The 8 mm formwork substantially reduced upper girder stresses: maximum top-flange compressive and tensile stresses fell by approximately 35% and 38% during erection and by 40% and 39% during casting, with deflection under dead and vehicle loads reduced by up to 3.9%. Increasing plate thickness from 6 to 8 mm clearly improved the response, while 10 mm gave limited further benefit. During repeated loading, cracks propagated, and stiffness degraded, but no visible steel–concrete interfacial slip was observed. After 2 million cycles, tensile strains in the midspan bottom plate and intermediate-support top reinforcement increased by approximately 13.4% and 21%, while initial flexural stiffness and ultimate flexural resistance decreased by approximately 10% and 9.7%, with residual resistance well above service-load demand. It serves as both construction formwork and a permanent structural component, informing design, plate-thickness selection, and durability assessment.
Open AccessGlobal Structural Performance and Repeated-Loading Effects of Steel–Concrete Composite Bridge Decks with Permanent Flat Steel Bottom Formwork
This study investigates the structural role of permanent flat steel bottom formwork in steel–concrete composite bridge decks from construction to long-term service through global numerical analysis and full-scale testing. A three-dimensional finite element model of a 3 × 40 m continuous composite girder bridge of the Beijing-Taipei (Jingtai) Expressway expansion project compared girders with and without the formwork during girder erection, concrete casting, secondary dead loading, and vehicle loading; a full-scale two-span specimen was tested under staged static loading, 2 million load cycles, and a failure test. The 8 mm formwork substantially reduced upper girder stresses: maximum top-flange compressive and tensile stresses fell by approximately 35% and 38% during erection and by 40% and 39% during casting, with deflection under dead and vehicle loads reduced by up to 3.9%. Increasing plate thickness from 6 to 8 mm clearly improved the response, while 10 mm gave limited further benefit. During repeated loading, cracks propagated, and stiffness degraded, but no visible steel–concrete interfacial slip was observed. After 2 million cycles, tensile strains in the midspan bottom plate and intermediate-support top reinforcement increased by approximately 13.4% and 21%, while initial flexural stiffness and ultimate flexural resistance decreased by approximately 10% and 9.7%, with residual resistance well above service-load demand. It serves as both construction formwork and a permanent structural component, informing design, plate-thickness selection, and durability assessment.
- Open Access
Investigation on Static Performance of Piers Assembled with Steel Cap Beams and Single Concrete Columns
To reduce the weight of prefabricated cap beams, a new type of hybrid pier with a steel cap beam and single concrete column with an innovative flange–rebar–ultra-high-performance concrete (UHPC) connection structure is proposed in this paper. Focusing on the static performance of hybrid piers, a specimen with a geometric similarity ratio of 1:4 was fabricated for testing. The results showed that the ultimate load-bearing capacity reached 960 kN, and the failure mode was characterized by an obvious overall vertical displacement of 70.2 mm at the cantilever end, accompanied by local buckling in the webs between transversal diaphragms and ribs. Due to the varying-thickness design, longitudinal strains were comparable between the middle section (thin plates) and the root section (thick plates) of the cantilever beam, showing a trend of an initial increase followed by a decrease from the end of the cantilever beam to the road centerline. Meanwhile, the cross-sections of the connection joint and concrete column transformed from overall compression to eccentric compression during the test. At the ultimate state, their steel structures remained elastic, with no obvious damage in the concrete or UHPC, verifying good load-bearing capacity. Furthermore, the finite element analysis showed the new connection joint and construction method of hinged-to-rigid could reduce the column top concrete compressive stress by 18–54%, tensile stress by 11–68%, and steel cap beam Mises stress by 10%. Finally, based on the experimental and numerical studies, the safety reserve coefficient of the new hybrid pier was over 2.7.
Open AccessInvestigation on Static Performance of Piers Assembled with Steel Cap Beams and Single Concrete Columns
To reduce the weight of prefabricated cap beams, a new type of hybrid pier with a steel cap beam and single concrete column with an innovative flange–rebar–ultra-high-performance concrete (UHPC) connection structure is proposed in this paper. Focusing on the static performance of hybrid piers, a specimen with a geometric similarity ratio of 1:4 was fabricated for testing. The results showed that the ultimate load-bearing capacity reached 960 kN, and the failure mode was characterized by an obvious overall vertical displacement of 70.2 mm at the cantilever end, accompanied by local buckling in the webs between transversal diaphragms and ribs. Due to the varying-thickness design, longitudinal strains were comparable between the middle section (thin plates) and the root section (thick plates) of the cantilever beam, showing a trend of an initial increase followed by a decrease from the end of the cantilever beam to the road centerline. Meanwhile, the cross-sections of the connection joint and concrete column transformed from overall compression to eccentric compression during the test. At the ultimate state, their steel structures remained elastic, with no obvious damage in the concrete or UHPC, verifying good load-bearing capacity. Furthermore, the finite element analysis showed the new connection joint and construction method of hinged-to-rigid could reduce the column top concrete compressive stress by 18–54%, tensile stress by 11–68%, and steel cap beam Mises stress by 10%. Finally, based on the experimental and numerical studies, the safety reserve coefficient of the new hybrid pier was over 2.7.