GJGyeong Hwan Ji

Gyeong Hwan Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gyeong Hwan Ji has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sensitivity Enhancement of Weak Reflection Signals in Reflectometry via Concurrent Pulse Superposition

    by Gyeong Hwan Ji, Gu-Young Kwon, Hyun-Mo Seong, Seung Jin Chang

    With the continuous expansion of modern electrical infrastructure, the scale and deployment of electrical cable networks have rapidly increased, underscoring the critical importance of systematic cable system maintenance. Among various diagnostic technologies, reflectometry has emerged as a highly effective and prominent methodology for precise fault detection and localization. Although the operational reliability of these networks fundamentally relies on precise fault detection, identifying minor or early-stage degradation remains a formidable challenge due to the marginal magnitude of the weak reflected signals. To address this limitation, this paper proposes a concurrent pulse superposition (CPS) method to enhance the detection sensitivity of weak reflection signatures in reflectometry without requiring expensive hardware modifications. The proposed method was evaluated through simulations covering fault resistances from 50Ω to 1000Ω and SNR levels from 15dB to 35dB. Across these conditions, CPS increased the reflection peak magnitude by approximately 2.5–3.5 times and maintained identifiable peaks in all tested cases, whereas the conventional method failed under several combinations of high fault resistance and low SNR. Consequently, this approach is expected to significantly empower the diagnostic analysis of extremely weak, early-stage faults, offering a practical solution for predictive maintenance in electrical systems.

  • Expectation–Maximization Framework for Fault Diagnosis in Branched Cable Networks via Time–Frequency Domain Reflectometry

    by Hobin Lim, Gyeong Hwan Ji, Yong-June Shin

    Time–frequency domain reflectometry (TFDR) has been widely used in industrial cable diagnostics for its high resolution and accurate fault localization. While TFDR is effective for localizing single faults or terminals of industrial cables, its performance is not guaranteed when applied to branched cable networks, where overlapping reflections from multiple terminations occur frequently. In particular, the diagnostic function of TFDR often interprets overlapping reflections as a single response, which complicates the estimation of terminal or fault locations. To address this challenge, we present a signal-level decomposition algorithm based on an enhanced expectation–maximization (EM) framework that directly separates measured waveforms. By decomposing the closely spaced waveforms, the method preserves waveform-level characteristics, enabling more detailed analysis of reflections. The method is experimentally validated on a branched cable testbed with comparable branch lengths, designed to emulate realistic diagnostic challenges. Experimental results demonstrate that the proposed algorithm improves reflection location accuracy compared to the state-of-the-art approach and reliably identifies the faulty branch under severe overlapped conditions.


  • Compensation for Connector-Induced Signal Distortion to Improve Reflectometry Performance

    by Gyeong Hwan Ji, Hobin Lim, Yong-June Shin

    A coaxial T-junction connector (TC) is a widely used cable accessory to split and integrate signals. This paper analyzes the side effects of the TC on the transmitted signal for an accurate measurement of its output signal in reflectometry. Two reflection phenomena are analyzed at the junction and the joints between the branch and the connected cables to estimate a precise output signal. To validate the proposed analysis, experiments with the TC are conducted for signal tracking. Three different experimental scenarios are investigated for comprehensive validation, and two estimated signals based on the assumption of impedance-matched conditions and the analyzed effect are comparatively interpreted with the measured signal. The similarity analysis between measurement and estimation demonstrates that the proposed calibration-based estimation is accurate in the measured signals of the TC in all scenarios. The uncertainty analysis of the characteristic impedance of the cable under test is performed to support the experimental validation.