Wentao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wentao Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jun Yang
Chongqing Institute of green and intelligent technology Chinese Academy of Sciences Chongqing China
1 shared publication - Keyu Meng
School of Electronic and Information Engineering, Changchun University, Changchun 130022, China
1 shared publication - Pei Li
Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
1 shared publication - Shipan Lang
Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China
1 shared publication - Yubo Sun
College of Electronic Information Engineering, Changchun University, Changchun 130022, China
1 shared publication
Latest Publications
- Open Access
Multi-Classification Model for PPG Signal Arrhythmia Based on Time–Frequency Dual-Domain Attention Fusion
Cardiac arrhythmia is a leading cause of sudden cardiac death. Its early detection and continuous monitoring hold significant clinical value. Photoplethysmography (PPG) signals, owing to their non-invasive nature, low cost, and convenience, have become a vital information source for monitoring cardiac activity and vascular health. However, the inherent non-stationarity of PPG signals and significant inter-individual variations pose a major challenge in developing highly accurate and efficient arrhythmia classification methods. To address this challenge, we propose a Fusion Deep Multi-domain Attention Network (Fusion-DMA-Net). Within this framework, we innovatively introduce a cross-scale residual attention structure to comprehensively capture discriminative features in both the time and frequency domains. Additionally, to exploit complementary information embedded in PPG signals across these domains, we develop a fusion strategy integrating interactive attention, self-attention, and gating mechanisms. The proposed Fusion-DMA-Net model is evaluated for classifying four major types of cardiac arrhythmias. Experimental results demonstrate its outstanding classification performance, achieving an overall accuracy of 99.05%, precision of 99.06%, and an F1-score of 99.04%. These results demonstrate the feasibility of the Fusion-DMA-Net model in classifying four types of cardiac arrhythmias using single-channel PPG signals, thereby contributing to the early diagnosis and treatment of cardiovascular diseases and supporting the development of future wearable health technologies.
Open AccessMulti-Classification Model for PPG Signal Arrhythmia Based on Time–Frequency Dual-Domain Attention Fusion
Cardiac arrhythmia is a leading cause of sudden cardiac death. Its early detection and continuous monitoring hold significant clinical value. Photoplethysmography (PPG) signals, owing to their non-invasive nature, low cost, and convenience, have become a vital information source for monitoring cardiac activity and vascular health. However, the inherent non-stationarity of PPG signals and significant inter-individual variations pose a major challenge in developing highly accurate and efficient arrhythmia classification methods. To address this challenge, we propose a Fusion Deep Multi-domain Attention Network (Fusion-DMA-Net). Within this framework, we innovatively introduce a cross-scale residual attention structure to comprehensively capture discriminative features in both the time and frequency domains. Additionally, to exploit complementary information embedded in PPG signals across these domains, we develop a fusion strategy integrating interactive attention, self-attention, and gating mechanisms. The proposed Fusion-DMA-Net model is evaluated for classifying four major types of cardiac arrhythmias. Experimental results demonstrate its outstanding classification performance, achieving an overall accuracy of 99.05%, precision of 99.06%, and an F1-score of 99.04%. These results demonstrate the feasibility of the Fusion-DMA-Net model in classifying four types of cardiac arrhythmias using single-channel PPG signals, thereby contributing to the early diagnosis and treatment of cardiovascular diseases and supporting the development of future wearable health technologies.