Francesca Camagni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Francesca Camagni has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Chiara Paganelli
2 shared publicationsGuido Baroni
2 shared publicationsAgnieszka Chalaszczyk
Radiation Oncology Unit, Clinical Department, CNAO National Center of Oncological Hadrontherapy, Pavia, Italy
1 shared publicationAlessandro Vai
Medical Physics Unit, Clinical Department, CNAO National Center of Oncological Hadrontherapy, Pavia, Italy
1 shared publicationAmelia Barcellini
Radiation Oncology Unit, Clinical Department, CNAO National Center of Oncological Hadrontherapy, Pavia, Italy
1 shared publicationAndrea Pella
Bioengineering Unit, Clinical Department, CNAO National Center of Oncological Hadrontherapy, Pavia, Italy
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
CycleGAN for Kernel-to-Kernel CT harmonization and low-dose CT denoising via transfer learning
- 11 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Open AccessCycleGAN for Kernel-to-Kernel CT harmonization and low-dose CT denoising via transfer learning
- Open Access
- 27 September 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (1) , 263-284
Generation of multimodal realistic computational phantoms as a test-bed for validating deep learning-based cross-modality synthesis techniques
The validation of multimodal deep learning models for medical image translation is limited by the lack of high-quality, paired datasets. We propose a novel framework that leverages computational phantoms to generate realistic CT and MRI images, enabling reliable ground-truth datasets for robust validation of artificial intelligence (AI) methods that generate synthetic CT (sCT) from MRI, specifically for radiotherapy applications. Two CycleGANs (cycle-consistent generative adversarial networks) were trained to transfer the imaging style of real patients onto CT and MRI phantoms, producing synthetic data with realistic textures and continuous intensity distributions. These data were evaluated through paired assessments with original phantoms, unpaired comparisons with patient scans, and dosimetric analysis using patient-specific radiotherapy treatment plans. Additional external validation was performed on public CT datasets to assess the generalizability to unseen data. The resulting, paired CT/MRI phantoms were used to validate a GAN-based model for sCT generation from abdominal MRI in particle therapy, available in the literature. Results showed strong anatomical consistency with original phantoms, high histogram correlation with patient images (HistCC = 0.998 ± 0.001 for MRI, HistCC = 0.97 ± 0.04 for CT), and dosimetric accuracy comparable to real data. The novelty of this work lies in using generated phantoms as validation data for deep learning-based cross-modality synthesis techniques. Graphical Abstract
- 27 September 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 64 (1) , 263-284
Open AccessGeneration of multimodal realistic computational phantoms as a test-bed for validating deep learning-based cross-modality synthesis techniques
The validation of multimodal deep learning models for medical image translation is limited by the lack of high-quality, paired datasets. We propose a novel framework that leverages computational phantoms to generate realistic CT and MRI images, enabling reliable ground-truth datasets for robust validation of artificial intelligence (AI) methods that generate synthetic CT (sCT) from MRI, specifically for radiotherapy applications. Two CycleGANs (cycle-consistent generative adversarial networks) were trained to transfer the imaging style of real patients onto CT and MRI phantoms, producing synthetic data with realistic textures and continuous intensity distributions. These data were evaluated through paired assessments with original phantoms, unpaired comparisons with patient scans, and dosimetric analysis using patient-specific radiotherapy treatment plans. Additional external validation was performed on public CT datasets to assess the generalizability to unseen data. The resulting, paired CT/MRI phantoms were used to validate a GAN-based model for sCT generation from abdominal MRI in particle therapy, available in the literature. Results showed strong anatomical consistency with original phantoms, high histogram correlation with patient images (HistCC = 0.998 ± 0.001 for MRI, HistCC = 0.97 ± 0.04 for CT), and dosimetric accuracy comparable to real data. The novelty of this work lies in using generated phantoms as validation data for deep learning-based cross-modality synthesis techniques. Graphical Abstract