Caleb M. Wagner
Research Subjects
Caleb M. Wagner has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alan T. Wall
Air Force Research Laboratory, Wright-Patterson AFB 3 , Ohio 45433, USA
1 shared publication - Chucri A. Kardous
National Institute for Occupational Safety and Health, 1090 Tusculum Avenue, Cincinnati, Ohio, USA
1 shared publication - Kent L. Gee
Department of Physics and Astronomy, Brigham Young University , Provo, Utah 84602
1 shared publication - Reese David Rasband
Ball Aerosp., 2875 Presidential Dr., Fairborn, OH 45324
1 shared publication - S. Hales Swift
Department of Photonic and Phononic Microsystems, Sandia National Laboratories, Albuquerque, NM, 87114, USA
1 shared publication - William J. Murphy
Hearing Loss Prevention Team, Centers for Disease Control and Prevention, National Inst. for Occupational Safety and Health, 1090 Tusculum Ave., Mailstop C-27, Cincinnati, OH 45226-1998
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 33 (1) , 040003
Impulse noise measurements of M16 rifles at Marine Base Quantico
This paper describes a study conducted at U.S. Marine Corps Base Quantico to determine firing range impulse noise levels and assess noise exposures. Measurements were performed with M16A4 rifles at an outdoor firing range, using a 113-channel array of 6.35 and 3.18 mm microphones that spanned potential locations for both shooters and instructors. Data were acquired using 24-bit cards at a sampling rate of 204.8 kHz. Single weapon measurements were made with and without an occupied range, with a shooter and with a remotely triggered gun stand. In addition, measurements were made with multiple shooters to simulate exposures for a realistic range environment. Results are shown for the various range configurations as a function of angle and distance. Analyses include waveforms, spectra, and peak levels, as well as the 10 ms equivalent level. All measurements met guidelines of the applicable military standard MIL-STD-1474E and the data are shown to be of high fidelity and useful for future in-depth analyses and noise dosage model development.
- 1 January 2018
- Published by Acoustical Society of America (ASA) in Proceedings of Meetings on Acoustics
- Vol. 33 (1) , 040003
Open AccessImpulse noise measurements of M16 rifles at Marine Base Quantico
This paper describes a study conducted at U.S. Marine Corps Base Quantico to determine firing range impulse noise levels and assess noise exposures. Measurements were performed with M16A4 rifles at an outdoor firing range, using a 113-channel array of 6.35 and 3.18 mm microphones that spanned potential locations for both shooters and instructors. Data were acquired using 24-bit cards at a sampling rate of 204.8 kHz. Single weapon measurements were made with and without an occupied range, with a shooter and with a remotely triggered gun stand. In addition, measurements were made with multiple shooters to simulate exposures for a realistic range environment. Results are shown for the various range configurations as a function of angle and distance. Analyses include waveforms, spectra, and peak levels, as well as the 10 ms equivalent level. All measurements met guidelines of the applicable military standard MIL-STD-1474E and the data are shown to be of high fidelity and useful for future in-depth analyses and noise dosage model development.