HBHaiquan Bi

Haiquan Bi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haiquan Bi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The diffusion of pollutants from diesel locomotives in high‐altitude railway tunnels

    by Xiaoping Xie, Yuanlong Zhou, Fulin Xia, Haiquan Bi, Honglin Wang

    With the continuous expansion of high‐altitude railway construction, pollutants emitted by diesel locomotives operating in long railway tunnels have become a major concern for tunnel air quality and passenger health. Therefore, a CFD‐based coupled tunnel–train–carriage model was established to investigate the dispersion characteristics of CO and NOx. The effects of fresh‐air ratio, train speed, and longitudinal ventilation velocity on pollutant distribution were systematically analyzed. The results indicate that NOx is the dominant pollutant affecting passenger exposure in high‐altitude railway tunnels. Pollutant concentrations within the tunnel were closely associated with train position, whereas in‐car pollutant concentrations continuously increased during train operation. Increasing the fresh‐air ratio from 20% to 50% increased the in‐car NOx concentration by approximately 104%. Even at a 20% fresh‐air ratio, the in‐car NOx concentration remained more than 100 times higher than the guideline value of 0.25 mg/m 3 . Increasing train speed significantly reduced pollutant concentrations in both the tunnel and passenger compartments. Dimensionless analysis revealed similar attenuation patterns for CO and NOx, despite their different concentrations. However, even at 110 km/h, the in‐car NOx concentration still exceeded the guideline value. Longitudinal ventilation reduced pollutant residence time within the tunnel but increased pollutant concentrations near roof‐mounted fresh‐air intakes, resulting in higher in‐car exposure levels. These findings provide a theoretical basis for tunnel ventilation design, train operation management, and air quality control in high‐altitude railway systems.

  • Cyclic salt‐spray study of pitting corrosion of coastal air‐conditioner aluminum fins with varying spacing, surface flatness, and placement angle

    by Congyun Lin, Yuanlong Zhou, Haiquan Bi, Honglin Wang, Tianxiao Zhu

    Pitting corrosion of aluminum fins in coastal air‐conditioner units degrades heat‐exchange performance. This study quantifies pitting corrosion of 6063 aluminum fin assemblies under cyclic neutral salt spray. A salt‐spray protocol (720 h, 42 cycles) was applied to fins with different spacings, surface flatness, dehumidification/desalination strategies, and placement angles. Net mass change was measured by a loss‐on‐drying gravimetric method and analyzed statistically. Fins with smaller spacing and corrugated surfaces showed a mass increase of approximately 2% from adherent corrosion products after 31 cycles. This increase was substantially larger than for smooth, widely spaced fins, indicating that narrow spacing and poor flatness intensify pitting damage. Under summer conditions, periodic water‐mist spraying combined with enclosure and desiccant produced the lowest cumulative mass change among all mitigation measures. In contrast, ozone treatment yielded only modest. The installation angle also significantly affected pitting corrosion. After 42 cycles, vertically mounted fins exhibited a corrosion weight‐loss ratio of 12.1%, approximately three times that of horizontal fins (4.0%), while tilted orientations showed intermediate behavior. These results demonstrate that liquid‐film thickness and renewal significantly influence the pitting corrosion of coastal aluminum fins, providing quantitative guidance for fin geometry, dehumidification scheduling, and placement angle in coastal air‐conditioning design.

  • A prediction model for concentration of gaseous pollutants in deeply buried water pipelines under longitudinal ventilation

    by Lingwei Feng, Yuanlong Zhou, Haiquan Bi, Shengxian Ou, Gongliang Liu, Li Li, Bo Lei

    This study investigates the diffusion mechanism of gaseous pollutants within the water pipeline under longitudinal ventilation by analyzing the effects of ventilation velocity, release rate, and distance to the air inlet vent. According to previous studies, NH 3 was chosen as the gaseous pollutant, and a series of numerical simulations were conducted. The results demonstrate that the airflow within the water pipeline is piston flow, the direction of which is determined by ventilation mode. Affected by the Coanda effect, the ununiform velocity leads to an uneven distribution of NH 3 on the water pipeline cross‐sections. The mean cross‐sectional values are chosen for further analysis. The concentration of NH 3 in the water pipeline is proportional to the release rate of NH 3 and distance to the air inlet vent, respectively. When the release rate is fixed, increasing the ventilation velocity can effectively remove the pollutant, and the concentration of NH 3 is proportional to the −1 power of the ventilation velocity. Finally, a prediction model of the mean cross‐sectional concentration of NH 3 is obtained by combining it with theoretical analysis. Therefore, this study can not only optimize the operation of the ventilation system in this Inter‐basin Water Transfer (IBWT) project but also guide the design of the ventilation system in other IBWT projects with deep buried long‐distance water pipelines.