David Gregocki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
David Gregocki has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Federica Baffigi
Intense Laser Irradiation Laboratory, INO CNR (National Council of Research) 6 , Pisa, Italy
2 shared publications - Fernando Brandi
Istituto Italiano di Tecnologia
2 shared publications - Gabriele Bandini
Intense Laser Irradiation Laboratory, National Institute of Optics, Consiglio Nazionale delle Ricerche (CNR), Via Giuseppe Moruzzi 1, 56124 Pisa, Italy
2 shared publications - Leonida Antonio Gizzi
Istituto Nazionale di Ottica
2 shared publications - Lorenzo Fulgentini
Intense Laser Irradiation Laboratory, National Institute of Optics, Consiglio Nazionale delle Ricerche (CNR), Via Giuseppe Moruzzi 1, 56124 Pisa, Italy
2 shared publications - Luca Labate
National Institute of Optics, National Research Council CNR-INO 1 , Pisa
2 shared publications
Latest Publications
- Open Access
- 23 October 2025
- Published by MDPI AG in Instruments
- Vol. 9 (4) , 25
Real-Time Dose Monitoring via Non-Destructive Charge Measurement of Laser-Driven Electrons for Medical Applications
Laser-accelerated electron beams, in the so-called Very High-Energy Electron (VHEE) energy range, are of great interest for biomedical applications. For instance, laser-driven VHEE beams are envisaged to offer suitable compact accelerators for the promising field of FLASH radiotherapy. Radiobiology experiments carried out using laser-driven beams require the real-time knowledge of the dose delivered to the sample. We have developed an online dose monitoring procedure, using an Integrating Current Transformer (ICT) coupled to a suitable collimator, that allows the estimation of the delivered dose on a shot-to-shot basis under suitable assumptions. The cross-calibration of the measured charge with standard offline dosimetry measurements carried out with RadioChromic Films (RCFs) is discussed, demonstrating excellent correlation between the two measurements.
- 23 October 2025
- Published by MDPI AG in Instruments
- Vol. 9 (4) , 25
Open AccessReal-Time Dose Monitoring via Non-Destructive Charge Measurement of Laser-Driven Electrons for Medical Applications
Laser-accelerated electron beams, in the so-called Very High-Energy Electron (VHEE) energy range, are of great interest for biomedical applications. For instance, laser-driven VHEE beams are envisaged to offer suitable compact accelerators for the promising field of FLASH radiotherapy. Radiobiology experiments carried out using laser-driven beams require the real-time knowledge of the dose delivered to the sample. We have developed an online dose monitoring procedure, using an Integrating Current Transformer (ICT) coupled to a suitable collimator, that allows the estimation of the delivered dose on a shot-to-shot basis under suitable assumptions. The cross-calibration of the measured charge with standard offline dosimetry measurements carried out with RadioChromic Films (RCFs) is discussed, demonstrating excellent correlation between the two measurements.
- Open Access
- 27 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Single-shot spectrometer with pointing angle correction for laser-driven electron beams featuring pointing instability and transverse inhomogeneity
- 27 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Open AccessSingle-shot spectrometer with pointing angle correction for laser-driven electron beams featuring pointing instability and transverse inhomogeneity