Jihu Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jihu Zhao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dayong Qi
Stroke Center, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai, China
1 shared publication - Meng Du
Stroke Center, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai, China
1 shared publication - Si Zhao Tang
Division of Interventional Radiology, Department of Diagnostic Imaging, National University Hospital (NUH), National University Health System (NUHS), Singapore, Singapore
1 shared publication - Yibin Fang
Translational Research Institute of Brain and Brain-like Intelligence, Department of Neurovascular Disease, Shanghai Fourth People’s Hospital, School of Medicine, Tongji University, Shanghai 200434, China
1 shared publication
Latest Publications
- 27 September 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
Subclavian loop catheterization technique (SLOT): novel transradial salvage technique for challenging vertebral artery ostial stenosis
Objective To evaluate the efficacy and safety of the subclavian loop catheter technique for endovascular stenting of vertebral artery ostial stenosis (VAOS). Methods We retrospectively reviewed all patients who underwent vertebral artery stenting between January 2022 and April 2025. The analysis included only those in whom standard transradial access (TRA) failed and the subclavian artery loop technique was used. Outcomes assessed included vascular access and surgical complications, postoperative modified Rankin Scale (mRS) scores, and in-stent restenosis on follow-up. Results Of 134 vertebral artery stenting procedures, 12 cases in which standard TRA failed were successfully completed using the subclavian loop catheter technique. Patients were aged 18–80 years, and VAOS was more frequent on the right side (n=11/12). Mean preoperative stenosis was 79%, reduced to 7.5% after stenting. No major periprocedural complications occurred. Median time from catheter loop formation to stent deployment was 33 min. Median follow-up was 3 months, during which 67% of patients were assessed and no in-stent restenosis was detected. Conclusions The subclavian loop catheter technique via TRA was a safe, effective, and feasible option for VAOS stenting when conventional radial or transfemoral access was limited by vascular anatomy. The technique provided stable access, enabled precise stent deployment, and demonstrated a favorable safety profile in this series.
- 27 September 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
Subclavian loop catheterization technique (SLOT): novel transradial salvage technique for challenging vertebral artery ostial stenosis
Objective To evaluate the efficacy and safety of the subclavian loop catheter technique for endovascular stenting of vertebral artery ostial stenosis (VAOS). Methods We retrospectively reviewed all patients who underwent vertebral artery stenting between January 2022 and April 2025. The analysis included only those in whom standard transradial access (TRA) failed and the subclavian artery loop technique was used. Outcomes assessed included vascular access and surgical complications, postoperative modified Rankin Scale (mRS) scores, and in-stent restenosis on follow-up. Results Of 134 vertebral artery stenting procedures, 12 cases in which standard TRA failed were successfully completed using the subclavian loop catheter technique. Patients were aged 18–80 years, and VAOS was more frequent on the right side (n=11/12). Mean preoperative stenosis was 79%, reduced to 7.5% after stenting. No major periprocedural complications occurred. Median time from catheter loop formation to stent deployment was 33 min. Median follow-up was 3 months, during which 67% of patients were assessed and no in-stent restenosis was detected. Conclusions The subclavian loop catheter technique via TRA was a safe, effective, and feasible option for VAOS stenting when conventional radial or transfemoral access was limited by vascular anatomy. The technique provided stable access, enabled precise stent deployment, and demonstrated a favorable safety profile in this series.