Regan Varner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Regan Varner has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Boland
Department of Electrical Engineering, Molinaroli College of Engineering and Computing, University of South Carolina, Columbia, SC, USA
1 shared publication - Aqarib Hussain
Dept. of Electrical Engineering, University of South Carolina Columbia
1 shared publication David W. Matolak
University of South Carolina
1 shared publication- David W. Matolak
Department of Electrical Engineering, University of South Carolina, Columbia, SC, USA
1 shared publication - Kristen Booth
Department of Electrical Engineering, University of South Carolina, Columbia, SC, USA
1 shared publication
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A 1-MHz, 5-kW LLC Converter for Electrified Transportation
This paper presents the design, implementation, and experimental validation of a 1-MHz, 5-kW LLC resonant converter, establishing a benchmark for kilowatt-class power conversion at megahertz frequencies. A unified methodology is developed to minimize total losses in GaN devices and magnetic components through co-optimization of the resonant tank and a closed-form, time-domain model for dead-time estimation. This model accurately captures the nonlinear output-capacitance behavior of GaN switches, ensuring zero voltage switching while reducing conduction losses. To achieve high power density, integrated PCB-based magnetics are employed, yielding a compact 40 W/cm3 design. The integration approach and layout inherently limit loop area and parasitic coupling, which are factors known to influence radiated EMI. A predictive radiated-EMI model, derived from time-domain waveforms, is validated against hardware measurements, demonstrating strong correlation. The research efforts coalesce in the experimental demonstration of a 1-MHz, 5-kW power converter, which is the largest power transfer demonstrated at 1 MHz to date.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A 1-MHz, 5-kW LLC Converter for Electrified Transportation
This paper presents the design, implementation, and experimental validation of a 1-MHz, 5-kW LLC resonant converter, establishing a benchmark for kilowatt-class power conversion at megahertz frequencies. A unified methodology is developed to minimize total losses in GaN devices and magnetic components through co-optimization of the resonant tank and a closed-form, time-domain model for dead-time estimation. This model accurately captures the nonlinear output-capacitance behavior of GaN switches, ensuring zero voltage switching while reducing conduction losses. To achieve high power density, integrated PCB-based magnetics are employed, yielding a compact 40 W/cm3 design. The integration approach and layout inherently limit loop area and parasitic coupling, which are factors known to influence radiated EMI. A predictive radiated-EMI model, derived from time-domain waveforms, is validated against hardware measurements, demonstrating strong correlation. The research efforts coalesce in the experimental demonstration of a 1-MHz, 5-kW power converter, which is the largest power transfer demonstrated at 1 MHz to date.
- Open Access
- 15 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Fourier Analysis of Power Converter Radiated Electromagnetic Interference
Power converters are widely used in industry for a variety of applications. For compactness and energy efficiency, higher switching frequency power converters are being designed. In addition to other challenges, the higher (MHz-range) switching frequencies produce larger amounts of radiated electromagnetic interference (EMI) at higher frequencies as well. This EMI needs to be characterized so that its effect on other nearby systems can be assessed. In this paper, we report on a Fourier analysis of the largest amplitude time-domain switching waveforms of a 1-MHz, 5-kW converter, conducted to estimate the radiated EMI. Our analytical results show good agreement with actual radiated EMI measurements for the frequency range from approximately 1 MHz to 25 MHz. At higher frequencies, the measured EMI shows larger values than predicted by analytical. One explanation for a portion of this higher EMI was found to be radiated tones from an auxiliary power supply and gate driver circuit. When these external tones are added to our analytical spectrum result, the agreement between analysis and measurements improves.
- 15 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessFourier Analysis of Power Converter Radiated Electromagnetic Interference
Power converters are widely used in industry for a variety of applications. For compactness and energy efficiency, higher switching frequency power converters are being designed. In addition to other challenges, the higher (MHz-range) switching frequencies produce larger amounts of radiated electromagnetic interference (EMI) at higher frequencies as well. This EMI needs to be characterized so that its effect on other nearby systems can be assessed. In this paper, we report on a Fourier analysis of the largest amplitude time-domain switching waveforms of a 1-MHz, 5-kW converter, conducted to estimate the radiated EMI. Our analytical results show good agreement with actual radiated EMI measurements for the frequency range from approximately 1 MHz to 25 MHz. At higher frequencies, the measured EMI shows larger values than predicted by analytical. One explanation for a portion of this higher EMI was found to be radiated tones from an auxiliary power supply and gate driver circuit. When these external tones are added to our analytical spectrum result, the agreement between analysis and measurements improves.