Latest Publications
- Open Access
- 1 November 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Solar radiation performance of courtyard proportions in a hot-dry climate: a validated simulation study of Ameri’s House, Kashan
- 1 November 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessSolar radiation performance of courtyard proportions in a hot-dry climate: a validated simulation study of Ameri’s House, Kashan
- Open Access
Context-Grounded Conceptual Design of an Environmentally Sustainable Hotel in Shiraz, Iran: Biomimicry, Voronoi Geometry, and Solar Energy Generation
This study presents a context-grounded conceptual design for an environmentally sustainable hotel in Shiraz, Iran, integrating three complementary strategies: a biomimicry-inspired responsive façade, a Voronoi-based façade and landscape design, and solar energy generation. Inspired by the adaptive behavior of morning glory flowers, the responsive façade is designed to adjust dynamically to environmental conditions with the aim of improving daylight utilization and thermal performance. Voronoi patterns are incorporated into the façade and landscape with the design intent of enhancing natural light distribution, airflow, structural efficiency, and aesthetic quality. In addition, photovoltaic panels installed on the hotel and parking roofs provide renewable energy to improve building sustainability. The façade and landscape geometry are developed parametrically in Rhinoceros 3D with Grasshopper, and the rooftop photovoltaic system is simulated using site-specific climate data for the project location. The System Advisor Model (SAM) simulations indicate that the proposed solar system can generate approximately 4,281,172 kWh of electricity annually, corresponding to approximately 9,889,507 lb (4486 t) of avoided CO2 relative to the cited U.S. coal generation benchmark. The integration of biomimicry, computational design, and renewable energy demonstrates an integrated conceptual approach to environmentally sustainable hotel architecture, with quantified solar energy generation and emissions reduction potential, and design-intent strategies for daylighting, thermal comfort, and occupant well-being that warrant further validation. This work presents an integrated design framework, not a validated or constructed building. Consistent with this scope, the term sustainability is used here in its environmental sense; the economic and social pillars are not assessed, and the study does not claim that Voronoi geometry is necessary for, or superior to, more regular and repetitive façade alternatives, a question that would require a controlled comparative study. The proposed design illustrates how nature-inspired strategies and advanced digital design methods can be combined to create innovative, resilient, and environmentally responsible buildings, providing a context-specific design proposition for future sustainable hospitality research.
Open AccessContext-Grounded Conceptual Design of an Environmentally Sustainable Hotel in Shiraz, Iran: Biomimicry, Voronoi Geometry, and Solar Energy Generation
This study presents a context-grounded conceptual design for an environmentally sustainable hotel in Shiraz, Iran, integrating three complementary strategies: a biomimicry-inspired responsive façade, a Voronoi-based façade and landscape design, and solar energy generation. Inspired by the adaptive behavior of morning glory flowers, the responsive façade is designed to adjust dynamically to environmental conditions with the aim of improving daylight utilization and thermal performance. Voronoi patterns are incorporated into the façade and landscape with the design intent of enhancing natural light distribution, airflow, structural efficiency, and aesthetic quality. In addition, photovoltaic panels installed on the hotel and parking roofs provide renewable energy to improve building sustainability. The façade and landscape geometry are developed parametrically in Rhinoceros 3D with Grasshopper, and the rooftop photovoltaic system is simulated using site-specific climate data for the project location. The System Advisor Model (SAM) simulations indicate that the proposed solar system can generate approximately 4,281,172 kWh of electricity annually, corresponding to approximately 9,889,507 lb (4486 t) of avoided CO2 relative to the cited U.S. coal generation benchmark. The integration of biomimicry, computational design, and renewable energy demonstrates an integrated conceptual approach to environmentally sustainable hotel architecture, with quantified solar energy generation and emissions reduction potential, and design-intent strategies for daylighting, thermal comfort, and occupant well-being that warrant further validation. This work presents an integrated design framework, not a validated or constructed building. Consistent with this scope, the term sustainability is used here in its environmental sense; the economic and social pillars are not assessed, and the study does not claim that Voronoi geometry is necessary for, or superior to, more regular and repetitive façade alternatives, a question that would require a controlled comparative study. The proposed design illustrates how nature-inspired strategies and advanced digital design methods can be combined to create innovative, resilient, and environmentally responsible buildings, providing a context-specific design proposition for future sustainable hospitality research.
- Open Access
- 26 May 2026
- Published by MDPI AG in Preprints.org
Post-Occupancy Evaluation to Examine the Quality of Female Student Housing Facilities: A Case Study of Iran
Student living environments have a significant impact on educational quality and academic outcomes. However, limited empirical research has focused on the condition of female student housing in Iran. This study conducts a post-occupancy evaluation (POE) of a representative on-campus female dormitory (Eram 3) at Shiraz University. A comprehensive evaluation framework was developed through an extensive literature review and structured into eleven performance indicators across three key dimensions: technical, functional, and behavioral. Data was collected using a 65-item questionnaire completed by 62 students who had resided in the building for at least one semester. Additional qualitative insights were gathered through focus group discussions and systematic observation, enhancing the reliability and contextual depth of the findings. Results indicate widespread dissatisfaction among residents, particularly in relation to indoor air quality, lighting, room layout, and privacy. The technical dimension received the lowest satisfaction scores, especially concerning air quality and lighting. Functionally, residents reported inadequate room sizes and limited flexibility in furniture arrangement. The behavioral dimension revealed dissatisfaction with visual privacy and the aesthetic quality of interior spaces. Based on these findings, the study proposes targeted improvements to ventilation systems, artificial and natural lighting, acoustic performance, and spatial layout. The research contributes to a gender-sensitive, user-centered POE framework applicable to similar residential environments in developing countries.
- 26 May 2026
- Published by MDPI AG in Preprints.org
Open AccessPost-Occupancy Evaluation to Examine the Quality of Female Student Housing Facilities: A Case Study of Iran
Student living environments have a significant impact on educational quality and academic outcomes. However, limited empirical research has focused on the condition of female student housing in Iran. This study conducts a post-occupancy evaluation (POE) of a representative on-campus female dormitory (Eram 3) at Shiraz University. A comprehensive evaluation framework was developed through an extensive literature review and structured into eleven performance indicators across three key dimensions: technical, functional, and behavioral. Data was collected using a 65-item questionnaire completed by 62 students who had resided in the building for at least one semester. Additional qualitative insights were gathered through focus group discussions and systematic observation, enhancing the reliability and contextual depth of the findings. Results indicate widespread dissatisfaction among residents, particularly in relation to indoor air quality, lighting, room layout, and privacy. The technical dimension received the lowest satisfaction scores, especially concerning air quality and lighting. Functionally, residents reported inadequate room sizes and limited flexibility in furniture arrangement. The behavioral dimension revealed dissatisfaction with visual privacy and the aesthetic quality of interior spaces. Based on these findings, the study proposes targeted improvements to ventilation systems, artificial and natural lighting, acoustic performance, and spatial layout. The research contributes to a gender-sensitive, user-centered POE framework applicable to similar residential environments in developing countries.
- Open Access
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Stack Ventilation vs. Cross Ventilation in Educational Buildings: Effect of Central Courtyard Design in a Hot and Dry Climate
Natural ventilation is a passive strategy for reducing cooling energy demand, improving indoor air quality, and ensuring occupant comfort, particularly in hot and arid regions. However, the comparative performance of different natural ventilation mechanisms in complex educational buildings remains underexplored. This study investigates and optimizes stack and cross ventilation in a courtyard-integrated art school in Kashan, Iran. Using high-resolution Computational Fluid Dynamics (CFD) simulations through Eddy3D(OpenFOAM engine), the research compares two ventilation scenarios: (1) cross ventilation through façade openings and (2) stack ventilation activated by courtyard openings. The coupled indoor–outdoor CFD model employs the RANS k–ε turbulence model, steady-state simulation, and a refined mesh of 1.7 million cells. Simulations were validated by airflow consistency across comparable rooms, identical meshing parameters, and convergence at 646 iterations with residuals of 10−4. Air velocity fields and thermal comfort were then assessed using the CBE Thermal Comfort Tool, considering local climatic conditions and occupant activity levels. The results demonstrate that stack ventilation significantly improves indoor airflow uniformity and enhances thermal comfort potential during operational periods (spring and early summer). Unlike cross ventilation, which generates uneven high-velocity zones near openings, stack ventilation balances airflow by reducing excessive velocities in exposed areas and increasing air movement in stagnant zones. This balance minimizes temperature gradients and supports comfort at up to 4°C higher indoor temperatures. The findings highlight the potential of courtyard-integrated stack ventilation to enhance passive cooling in educational buildings, offering a validated framework for architects and engineers to optimize natural ventilation performance in arid climates.
- 20 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessStack Ventilation vs. Cross Ventilation in Educational Buildings: Effect of Central Courtyard Design in a Hot and Dry Climate
Natural ventilation is a passive strategy for reducing cooling energy demand, improving indoor air quality, and ensuring occupant comfort, particularly in hot and arid regions. However, the comparative performance of different natural ventilation mechanisms in complex educational buildings remains underexplored. This study investigates and optimizes stack and cross ventilation in a courtyard-integrated art school in Kashan, Iran. Using high-resolution Computational Fluid Dynamics (CFD) simulations through Eddy3D(OpenFOAM engine), the research compares two ventilation scenarios: (1) cross ventilation through façade openings and (2) stack ventilation activated by courtyard openings. The coupled indoor–outdoor CFD model employs the RANS k–ε turbulence model, steady-state simulation, and a refined mesh of 1.7 million cells. Simulations were validated by airflow consistency across comparable rooms, identical meshing parameters, and convergence at 646 iterations with residuals of 10−4. Air velocity fields and thermal comfort were then assessed using the CBE Thermal Comfort Tool, considering local climatic conditions and occupant activity levels. The results demonstrate that stack ventilation significantly improves indoor airflow uniformity and enhances thermal comfort potential during operational periods (spring and early summer). Unlike cross ventilation, which generates uneven high-velocity zones near openings, stack ventilation balances airflow by reducing excessive velocities in exposed areas and increasing air movement in stagnant zones. This balance minimizes temperature gradients and supports comfort at up to 4°C higher indoor temperatures. The findings highlight the potential of courtyard-integrated stack ventilation to enhance passive cooling in educational buildings, offering a validated framework for architects and engineers to optimize natural ventilation performance in arid climates.
- Open Access
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Solar Radiation Performance of Courtyard Proportions in a Hot-Dry Climate: A Validated Simulation Study of Ameri’s House, Kashan
This study evaluates solar radiation patterns in the central courtyards of Ameri’s House (Kashan, Iran) to determine optimal geometric proportions and orientation strategies for hot–dry climates. High-resolution daylight measurements from a previous field study were collected on July 12 at 10-minute intervals and converted to solar radiation values to correspond with simulation outputs. A digital model was developed in Rhino-Grasshopper, and roof-level solar irradiance was simulated using Ladybug Tools for the same date, generating 14 hourly values from 6:30 to 19:30. Model reliability was assessed using the coefficient of variation of the root mean square error (CV-RMSE), which was 20.2%. This value falls within the recommended threshold for hourly data (<30%), indicating consistency between measured and simulated radiation profiles. Following validation, annual solar radiation and shading analyses were conducted for four cardinal orientations on four representative seasonal dates. Courtyard floor surfaces were examined at 10:00, 12:00, 14:00, and 16:00 to enable seasonal and diurnal comparisons of radiation intensity and shading distribution. The results indicate that courtyards with length-to-width ratios of approximately 1.34–1.35, combined with a north–south orientation, achieve the most balanced solar performance by providing effective summer shading and maintaining passive solar gains in winter. These findings present evidence-based guidelines for climate-responsive courtyard design and support heritage refurbishment, adaptive reuse, and orientation-driven environmental design at both building and urban scales.
- 9 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSolar Radiation Performance of Courtyard Proportions in a Hot-Dry Climate: A Validated Simulation Study of Ameri’s House, Kashan
This study evaluates solar radiation patterns in the central courtyards of Ameri’s House (Kashan, Iran) to determine optimal geometric proportions and orientation strategies for hot–dry climates. High-resolution daylight measurements from a previous field study were collected on July 12 at 10-minute intervals and converted to solar radiation values to correspond with simulation outputs. A digital model was developed in Rhino-Grasshopper, and roof-level solar irradiance was simulated using Ladybug Tools for the same date, generating 14 hourly values from 6:30 to 19:30. Model reliability was assessed using the coefficient of variation of the root mean square error (CV-RMSE), which was 20.2%. This value falls within the recommended threshold for hourly data (<30%), indicating consistency between measured and simulated radiation profiles. Following validation, annual solar radiation and shading analyses were conducted for four cardinal orientations on four representative seasonal dates. Courtyard floor surfaces were examined at 10:00, 12:00, 14:00, and 16:00 to enable seasonal and diurnal comparisons of radiation intensity and shading distribution. The results indicate that courtyards with length-to-width ratios of approximately 1.34–1.35, combined with a north–south orientation, achieve the most balanced solar performance by providing effective summer shading and maintaining passive solar gains in winter. These findings present evidence-based guidelines for climate-responsive courtyard design and support heritage refurbishment, adaptive reuse, and orientation-driven environmental design at both building and urban scales.
- 24 September 2025
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 19 (1) , 311-324
The Potential Role of the Physical Environment in Telehealth: A Patient-Centered Care Perspective
Background: The delivery of preventive and primary care has evolved through various physical environments, from early twentieth-century house calls to centralized settings like physician offices and hospitals, and more recently, through rapid adoption of telehealth. This shift occurred amidst an increasing emphasis on patient/person-centered care models. Aim: This article conceptually examines the role of the physical environment in optimizing patient/person-centered care within telehealth, focusing on preventive and primary care in the pre-acute stages. Method: A rapid scoping review was conducted to identify key underlying dimensions of patient/person-centered care. Each dimension was further examined to identify theoretical background and measurement instruments used in the field, to obtain a detailed comprehension of the concepts. A series of brainstorming sessions among contributing authors, in association with logical theory-supported arguments, were conducted to articulate conceptual associations and detect the potential role of the physical environment. Result: An articulation of the relationships between six underlying dimensions of patient/person-centered care is proposed: Shared Decision-Making, Autonomy, Communication, Empathy, Trust, and Privacy. Furthermore, the potential role of the physical environment in the pathway to patient outcomes is posited. Conclusions: Physical separation of providers and patients may present challenges to achieving optimal performance in key dimensions of patient/person-centered care. The physical environment of telehealth care has a potential role to play in care optimization.
- 24 September 2025
- Published by SAGE Publications in HERD: Health Environments Research & Design Journal
- Vol. 19 (1) , 311-324
The Potential Role of the Physical Environment in Telehealth: A Patient-Centered Care Perspective
Background: The delivery of preventive and primary care has evolved through various physical environments, from early twentieth-century house calls to centralized settings like physician offices and hospitals, and more recently, through rapid adoption of telehealth. This shift occurred amidst an increasing emphasis on patient/person-centered care models. Aim: This article conceptually examines the role of the physical environment in optimizing patient/person-centered care within telehealth, focusing on preventive and primary care in the pre-acute stages. Method: A rapid scoping review was conducted to identify key underlying dimensions of patient/person-centered care. Each dimension was further examined to identify theoretical background and measurement instruments used in the field, to obtain a detailed comprehension of the concepts. A series of brainstorming sessions among contributing authors, in association with logical theory-supported arguments, were conducted to articulate conceptual associations and detect the potential role of the physical environment. Result: An articulation of the relationships between six underlying dimensions of patient/person-centered care is proposed: Shared Decision-Making, Autonomy, Communication, Empathy, Trust, and Privacy. Furthermore, the potential role of the physical environment in the pathway to patient outcomes is posited. Conclusions: Physical separation of providers and patients may present challenges to achieving optimal performance in key dimensions of patient/person-centered care. The physical environment of telehealth care has a potential role to play in care optimization.