Xiaogang Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaogang Sun has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Gao Cheng
School of Highway, Chang’an University, Xi’an 710064, China
2 shared publications - Guangjin Zhou
School of Highway, Chang’an University, Xi’an 710064, China
2 shared publications - Baojun Zhao
School of Highway, Chang’an University, Xi’an 710064, China
1 shared publication - Chuyin Wei
Dongguan Jiaoye Engineering Quality Testing Co., Ltd., Dongguan 523000, China
1 shared publication - Shaojie Zheng
Dongguan Communications Investment Holding Group Co., Ltd., Dongguan 523000, China
1 shared publication
Latest Publications
- Open Access
Study on Mechanical Performance of Steel Truss–Concrete Composite Girder During Post-Rotation Jacking Process
Post-rotation jacking is a critical construction stage for load-path reconstruction and alignment adjustment in rotation-constructed bridges, particularly for ultra-wide double-deck composite girder systems. Taking a two-span continuous steel truss–concrete composite girder bridge with spans of 2 × 85 m as the engineering background, this study investigates the mechanical behavior during post-rotation jacking through theoretical derivation, finite element simulation, and on-site monitoring. Based on the force method of structural mechanics, a linear relationship between vertical synchronous jacking force and displacement is derived, and an analytical formulation for bearing reaction redistribution under laterally asynchronous jacking is established by considering the coupling effects of vertical bending, torsion, and transverse multi-bearing support. A full-bridge spatial finite element model was developed in MIDAS Civil NX 2024 V1.1 to analyze the redistribution of bearing reactions and the stress response of the concrete crossbeam under different jacking conditions. The results show that, for the investigated bridge, the jacking force–displacement response remains highly linear during synchronous jacking. The B-axis middle bearing is more sensitive to jacking displacement than the two side bearings, with its fitted stiffness being approximately 2.19 times the average stiffness of the side bearings. Eccentric jacking causes reaction concentration at the jacked point and reaction reduction at adjacent supports, and the magnitude of reaction variation increases approximately linearly with jacking displacement. When the transverse non-uniform jacking magnitude reaches 20 mm, a tensile stress of 0.3 MPa appears at the bottom flange of the concrete crossbeam; therefore, a project-specific stroke-difference limit of 20 mm is recommended for this bridge, while the actual construction achieved a stroke control accuracy of ±0.5 mm and a transverse elevation difference within 1 mm. Field monitoring results validate the proposed analytical and numerical methods. The Pearson correlation coefficients of the measured jacking forces with the finite element and theoretical results are 0.9987 and 0.9988, respectively, and the corresponding mean relative errors are 3.84% and 4.23%. For stress responses, the measured and calculated values show a strong correlation, with a Pearson correlation coefficient of 0.9980 and a mean relative error of 12.77%; the critical mid-span monitoring point shows a relative error of only 0.65%. The final bridge alignment deviation is controlled within ±3 cm. The overall mean verification coefficient is 0.968, with a 95% empirical agreement range of [0.888, 1.048], indicating that the proposed mechanical analysis framework and combined force–displacement control strategy can provide a useful reference for refined construction control of similar ultra-wide double-deck composite girder bridges with comparable span arrangement and transverse bearing layout.
Open AccessStudy on Mechanical Performance of Steel Truss–Concrete Composite Girder During Post-Rotation Jacking Process
Post-rotation jacking is a critical construction stage for load-path reconstruction and alignment adjustment in rotation-constructed bridges, particularly for ultra-wide double-deck composite girder systems. Taking a two-span continuous steel truss–concrete composite girder bridge with spans of 2 × 85 m as the engineering background, this study investigates the mechanical behavior during post-rotation jacking through theoretical derivation, finite element simulation, and on-site monitoring. Based on the force method of structural mechanics, a linear relationship between vertical synchronous jacking force and displacement is derived, and an analytical formulation for bearing reaction redistribution under laterally asynchronous jacking is established by considering the coupling effects of vertical bending, torsion, and transverse multi-bearing support. A full-bridge spatial finite element model was developed in MIDAS Civil NX 2024 V1.1 to analyze the redistribution of bearing reactions and the stress response of the concrete crossbeam under different jacking conditions. The results show that, for the investigated bridge, the jacking force–displacement response remains highly linear during synchronous jacking. The B-axis middle bearing is more sensitive to jacking displacement than the two side bearings, with its fitted stiffness being approximately 2.19 times the average stiffness of the side bearings. Eccentric jacking causes reaction concentration at the jacked point and reaction reduction at adjacent supports, and the magnitude of reaction variation increases approximately linearly with jacking displacement. When the transverse non-uniform jacking magnitude reaches 20 mm, a tensile stress of 0.3 MPa appears at the bottom flange of the concrete crossbeam; therefore, a project-specific stroke-difference limit of 20 mm is recommended for this bridge, while the actual construction achieved a stroke control accuracy of ±0.5 mm and a transverse elevation difference within 1 mm. Field monitoring results validate the proposed analytical and numerical methods. The Pearson correlation coefficients of the measured jacking forces with the finite element and theoretical results are 0.9987 and 0.9988, respectively, and the corresponding mean relative errors are 3.84% and 4.23%. For stress responses, the measured and calculated values show a strong correlation, with a Pearson correlation coefficient of 0.9980 and a mean relative error of 12.77%; the critical mid-span monitoring point shows a relative error of only 0.65%. The final bridge alignment deviation is controlled within ±3 cm. The overall mean verification coefficient is 0.968, with a 95% empirical agreement range of [0.888, 1.048], indicating that the proposed mechanical analysis framework and combined force–displacement control strategy can provide a useful reference for refined construction control of similar ultra-wide double-deck composite girder bridges with comparable span arrangement and transverse bearing layout.
- Open Access
Research on the Design Method of Laminated Glass Bridge Deck for Vehicle Applications
Owing to the light-transmitting, energy-saving, and load-bearing properties of glass, laminated glass has gradually been adopted as vehicle lane surfaces in scenarios such as multi-storey commercial complexes, glass walkways roads, and underground parking lots. However, currently, a mature design system for vehicle-borne glass bridge decks is still lacking, and the existing design system for pedestrian glass bridge decks cannot be directly applied to vehicle-borne scenarios. Combining domestic and international specifications and research, this study focused on material selection, structural configuration, and structural calculation of vehicle-borne glass bridge decks, proposed a targeted design method, and verified it with engineering examples. The key conclusions are as follows: (1) Laminated glass for bridge decks should preferably use homogenized tempered glass with SGP as the interlayer material; the number of glass layers should be controlled between 3 and 5, the aspect ratio of glass panels should be maintained between 1 and 2, the thickness of a single glass panel should not be less than 8 mm, and the interlayer thickness should be between 0.76 mm and 2.28 mm. (2) This study proposes design loads, load combination methods, calculation models, design criteria, and the equivalent thickness calculation method for vehicle-borne glass bridge decks; meanwhile, it incorporates the adverse working condition of single-layer glass breakage into design considerations. (3) The design method shows good agreement with numerical simulation results: both PVB and SGP-laminated glass can meet the load-bearing capacity requirements, but SGP-laminated glass has a larger safety redundancy under the same thickness; after single-layer glass breakage, the bridge deck still has sufficient load-bearing capacity; the calculation results of the design method are slightly more conservative than the finite element calculation results, but the calculation of stress and deflection for SGP-laminated glass is relatively accurate. (4) Future research will further deepen the study on the impact of the long-term performance of laminated glass on the full-life-cycle of vehicle-borne glass bridge decks and improve this design method.
Open AccessResearch on the Design Method of Laminated Glass Bridge Deck for Vehicle Applications
Owing to the light-transmitting, energy-saving, and load-bearing properties of glass, laminated glass has gradually been adopted as vehicle lane surfaces in scenarios such as multi-storey commercial complexes, glass walkways roads, and underground parking lots. However, currently, a mature design system for vehicle-borne glass bridge decks is still lacking, and the existing design system for pedestrian glass bridge decks cannot be directly applied to vehicle-borne scenarios. Combining domestic and international specifications and research, this study focused on material selection, structural configuration, and structural calculation of vehicle-borne glass bridge decks, proposed a targeted design method, and verified it with engineering examples. The key conclusions are as follows: (1) Laminated glass for bridge decks should preferably use homogenized tempered glass with SGP as the interlayer material; the number of glass layers should be controlled between 3 and 5, the aspect ratio of glass panels should be maintained between 1 and 2, the thickness of a single glass panel should not be less than 8 mm, and the interlayer thickness should be between 0.76 mm and 2.28 mm. (2) This study proposes design loads, load combination methods, calculation models, design criteria, and the equivalent thickness calculation method for vehicle-borne glass bridge decks; meanwhile, it incorporates the adverse working condition of single-layer glass breakage into design considerations. (3) The design method shows good agreement with numerical simulation results: both PVB and SGP-laminated glass can meet the load-bearing capacity requirements, but SGP-laminated glass has a larger safety redundancy under the same thickness; after single-layer glass breakage, the bridge deck still has sufficient load-bearing capacity; the calculation results of the design method are slightly more conservative than the finite element calculation results, but the calculation of stress and deflection for SGP-laminated glass is relatively accurate. (4) Future research will further deepen the study on the impact of the long-term performance of laminated glass on the full-life-cycle of vehicle-borne glass bridge decks and improve this design method.