Rifqi Fajar Maulana
Research Subjects
Rifqi Fajar Maulana has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ai-Phuong Nguyen
Institute of Atomic and Molecular Sciences, Academia Sinica
1 shared publication Akhmad Sabarudin
Department of Chemistry, Faculty of Mathematics and Natural Sciences Brawijaya University Malang Indonesia
1 shared publication- Andri Hardiansyah
Research Center for Nanotechnology Systems, National Research and Innovation Agency (BRIN), Tangerang Selatan, Indonesia
1 shared publication Angga Hermawan
Research Center for Nanotechnology Systems, National Research and Innovation Agency (BRIN) Tangerang Selatan Indonesia
1 shared publication- Carlos Jose Quiroz Reyes
Institute of Atomic and Molecular Sciences, Academia Sinica
1 shared publication - Chi-Ling Chiang
Institute of Zoology, National Taiwan University, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 25 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Bright alkyl quantum defects govern early carbon nanotube pharmacokinetics in mice
Fluorescent quantum defects in single-wall carbon nanotubes (SWCNTs) are a major advance in nanocarbon research, owing to their bright, single-photon emission at telecom wavelengths and versatile conjugation chemistries for biomedical sensing and disease targeting. Here, we introduce an efficient, oxygen-free sonochemical route that generates long-chain alkyl defects, simultaneously shortening nanotubes and producing a bright, homogeneously emissive (6,5) SWCNT ensemble. Among 15 screened surfactants and initiators, the branched-chain Niaproof ® 4, which molecular dynamics simulations show packs more densely and uniformly than linear surfactants, yields a 3.4-fold brightness enhancement and a sharp emission peak near 1108 nm. Single-particle spectroscopy reveals J-aggregate emission redshifts at high defect densities, and fibrinogen titration shows defect chemistry governs protein-driven coating displacement. Using a home-built short-wave infrared imaging system (25 mW cm −2 , 989 nm excitation, 1150 nm longpass collection), we show that these sparse defects (~15.2 μm −1 ) drive different, nonmonotonic pharmacokinetics between Niaproof ® 4– and lipid-PEG–functionalized (6,5) at early time points, converging as protein-corona formation masks the underlying chemistry. Histology localizes the nanotubes within macrophages of mononuclear phagocyte system–associated organs. Intravenous administration (50 μg kg −1 ) shows no acute toxicity and short ~2-day retention, while the Niaproof ® 4 group depletes more myeloid cells after corona formation.
- 25 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessBright alkyl quantum defects govern early carbon nanotube pharmacokinetics in mice
Fluorescent quantum defects in single-wall carbon nanotubes (SWCNTs) are a major advance in nanocarbon research, owing to their bright, single-photon emission at telecom wavelengths and versatile conjugation chemistries for biomedical sensing and disease targeting. Here, we introduce an efficient, oxygen-free sonochemical route that generates long-chain alkyl defects, simultaneously shortening nanotubes and producing a bright, homogeneously emissive (6,5) SWCNT ensemble. Among 15 screened surfactants and initiators, the branched-chain Niaproof ® 4, which molecular dynamics simulations show packs more densely and uniformly than linear surfactants, yields a 3.4-fold brightness enhancement and a sharp emission peak near 1108 nm. Single-particle spectroscopy reveals J-aggregate emission redshifts at high defect densities, and fibrinogen titration shows defect chemistry governs protein-driven coating displacement. Using a home-built short-wave infrared imaging system (25 mW cm −2 , 989 nm excitation, 1150 nm longpass collection), we show that these sparse defects (~15.2 μm −1 ) drive different, nonmonotonic pharmacokinetics between Niaproof ® 4– and lipid-PEG–functionalized (6,5) at early time points, converging as protein-corona formation masks the underlying chemistry. Histology localizes the nanotubes within macrophages of mononuclear phagocyte system–associated organs. Intravenous administration (50 μg kg −1 ) shows no acute toxicity and short ~2-day retention, while the Niaproof ® 4 group depletes more myeloid cells after corona formation.
- 16 July 2025
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 72 (11) , 1290-1304
Fabrication and electrochemical performance of polypyrrole/ Fe 3 O 4 /graphene nanoplatelets‐modified glassy carbon electrode for detection of dopamine
Dopamine (DA) is a crucial neurotransmitter involved in metabolism, the immune system, and hormonal regulation. However, its accurate detection is challenging due to interference from compounds such as uric acid (UA) and ascorbic acid (AA). Here, we developed a polypyrrole/iron oxide/graphene nanoplatelet (PPy/Fe 3 O 4 /GNP)‐modified glassy carbon electrode (GCE) for the selective detection of DA. FESEM analysis revealed a spherical bead‐like morphology with a surface sheet of PPy, Fe 3 O 4 , and GNP. Electrochemical performance evaluation demonstrated that the PPy/Fe 3 O 4 /GNP‐modified GCE possessed a high electroactive surface area (ECSA), that is, 0.099 cm 2 , facilitating enhanced electron transfer. The sensor exhibited a linear detection range of 5.25–1000 μM and a limit of detection (LOD) of 5.25 μM for DA. Upon the addition of UA and AA, their oxidation peaks remained well‐separated from the DA oxidation peak, confirming the selectivity of the PPy/Fe 3 O 4 /GNP‐modified GCE. Furthermore, the sensor demonstrated excellent stability for 5 days with a Relative Standard Deviation (RSD) value of 28%, repeatability up to 50 cycles with an RSD value of 24.21%, and reproducibility on three different electrodes, giving the same response pattern with an RSD value of 5.55%. The real sample analysis using human serum yielded a recovery percentage of 82.17%–120.91%, indicating the sensor's reliability in biological sample detection. In conclusion, the PPy/Fe 3 O 4 /GNP‐modified GCE is a highly sensitive and selective electrochemical sensor for DA detection, effectively minimizing interference from UA and AA. These findings highlight its potential for reliable neurotransmitter‐sensing applications.
- 16 July 2025
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 72 (11) , 1290-1304
Fabrication and electrochemical performance of polypyrrole/ Fe 3 O 4 /graphene nanoplatelets‐modified glassy carbon electrode for detection of dopamine
Dopamine (DA) is a crucial neurotransmitter involved in metabolism, the immune system, and hormonal regulation. However, its accurate detection is challenging due to interference from compounds such as uric acid (UA) and ascorbic acid (AA). Here, we developed a polypyrrole/iron oxide/graphene nanoplatelet (PPy/Fe 3 O 4 /GNP)‐modified glassy carbon electrode (GCE) for the selective detection of DA. FESEM analysis revealed a spherical bead‐like morphology with a surface sheet of PPy, Fe 3 O 4 , and GNP. Electrochemical performance evaluation demonstrated that the PPy/Fe 3 O 4 /GNP‐modified GCE possessed a high electroactive surface area (ECSA), that is, 0.099 cm 2 , facilitating enhanced electron transfer. The sensor exhibited a linear detection range of 5.25–1000 μM and a limit of detection (LOD) of 5.25 μM for DA. Upon the addition of UA and AA, their oxidation peaks remained well‐separated from the DA oxidation peak, confirming the selectivity of the PPy/Fe 3 O 4 /GNP‐modified GCE. Furthermore, the sensor demonstrated excellent stability for 5 days with a Relative Standard Deviation (RSD) value of 28%, repeatability up to 50 cycles with an RSD value of 24.21%, and reproducibility on three different electrodes, giving the same response pattern with an RSD value of 5.55%. The real sample analysis using human serum yielded a recovery percentage of 82.17%–120.91%, indicating the sensor's reliability in biological sample detection. In conclusion, the PPy/Fe 3 O 4 /GNP‐modified GCE is a highly sensitive and selective electrochemical sensor for DA detection, effectively minimizing interference from UA and AA. These findings highlight its potential for reliable neurotransmitter‐sensing applications.