Zhan'ANxin Tong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhan'ANxin Tong has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Asif Ali
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications - Frede Blaabjerg
Aalborg University
2 shared publications - Jian Zhang
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications - Jianhui Su
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications Gang Yang
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
1 shared publication- Gang Yang
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
1 shared publication
Latest Publications
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10376-10390
Physics-Informed Neural Networks for Joint Estimation of Multiparameters and Coil Misalignment in IPT Systems
In inductive power transfer (IPT) systems, real-time perception of mutual inductance and load parameters is critical for regulating operating states and monitoring system conditions. This article proposes a physics-informed neural network (PINN)-based multiparameter joint identification method. By embedding physical constraints of impedance angle-mutual inductance-load relationships as domain knowledge, PINN is guided to learn system dynamics. The performance is further enhanced by integrating the convolutional block attention module, which outperforms other attention mechanisms with very low convergence loss. Experiments on a 10 kW low-voltage, high-current IPT platform validate the high-precision identification: relative errors of 7.7% (coil displacement), 2.1% (mutual inductance), 2.0% (leakage inductance), and 1.8% (load). The method operates without system modification or additional hardware, making it suitable for online parameter identification and real-time monitoring in high misalignment and wide-load-range IPT applications.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10376-10390
Physics-Informed Neural Networks for Joint Estimation of Multiparameters and Coil Misalignment in IPT Systems
In inductive power transfer (IPT) systems, real-time perception of mutual inductance and load parameters is critical for regulating operating states and monitoring system conditions. This article proposes a physics-informed neural network (PINN)-based multiparameter joint identification method. By embedding physical constraints of impedance angle-mutual inductance-load relationships as domain knowledge, PINN is guided to learn system dynamics. The performance is further enhanced by integrating the convolutional block attention module, which outperforms other attention mechanisms with very low convergence loss. Experiments on a 10 kW low-voltage, high-current IPT platform validate the high-precision identification: relative errors of 7.7% (coil displacement), 2.1% (mutual inductance), 2.0% (leakage inductance), and 1.8% (load). The method operates without system modification or additional hardware, making it suitable for online parameter identification and real-time monitoring in high misalignment and wide-load-range IPT applications.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11714-11727
Analysis and Design of a Dual-Coupled LCC-S Compensated IPT System Considering Air Gap Variation
In inductive power transfer (IPT) systems, variations in the air gap can affect the self-inductance and mutual inductance of the loosely coupled transformer (LCT). As the resonant frequency is primarily determined by the self-inductance and the compensation capacitance, any variation in self-inductance can cause the resonant frequency to deviate from its designed value, resulting in reduced output gain and efficiency. To address this issue, a dual-coupled LCC-S compensated IPT system with a three-coil LCT is proposed. The key idea is to utilize the additional degree of freedom provided by the coupling between the compensation coil and the secondary coil to adjust the system’s resonant frequency. By introducing a compensation coupling factor and determining its optimal value through a cost function, the frequency for zero phase angle (ZPA) input can be converged into a minimal range across the predetermined air gap range. Based on this, by selecting an appropriate operating frequency near the resonant frequency range, zero-voltage switching (ZVS) can be achieved, leading to a reduction in reactive current and switching loss. Subsequently, the parametric design process of the LCT with an optimal compensation coupling factor is elaborated. A 4.5-kW prototype was built and the experimental results have verified the theoretical analysis. The system operates at 85.5 kHz with a maximum input impedance angle of 12.2° across the air gap range of 40–120 mm, while the self-inductance varies by 17.5% and mutual inductance by 245%. The peak efficiency of the system is 95.2%.
- 19 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11714-11727
Analysis and Design of a Dual-Coupled LCC-S Compensated IPT System Considering Air Gap Variation
In inductive power transfer (IPT) systems, variations in the air gap can affect the self-inductance and mutual inductance of the loosely coupled transformer (LCT). As the resonant frequency is primarily determined by the self-inductance and the compensation capacitance, any variation in self-inductance can cause the resonant frequency to deviate from its designed value, resulting in reduced output gain and efficiency. To address this issue, a dual-coupled LCC-S compensated IPT system with a three-coil LCT is proposed. The key idea is to utilize the additional degree of freedom provided by the coupling between the compensation coil and the secondary coil to adjust the system’s resonant frequency. By introducing a compensation coupling factor and determining its optimal value through a cost function, the frequency for zero phase angle (ZPA) input can be converged into a minimal range across the predetermined air gap range. Based on this, by selecting an appropriate operating frequency near the resonant frequency range, zero-voltage switching (ZVS) can be achieved, leading to a reduction in reactive current and switching loss. Subsequently, the parametric design process of the LCT with an optimal compensation coupling factor is elaborated. A 4.5-kW prototype was built and the experimental results have verified the theoretical analysis. The system operates at 85.5 kHz with a maximum input impedance angle of 12.2° across the air gap range of 40–120 mm, while the self-inductance varies by 17.5% and mutual inductance by 245%. The peak efficiency of the system is 95.2%.