Chenju Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenju Zhou has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jie Li
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications - Shunmin Yang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications - Yi Bo
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications - Chenjun Hu
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
1 shared publication - Kaiqiang Feng
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
1 shared publication - Yutao Tian
School of Instrument and Electronics, North University of China, Taiyuan 030051, China
1 shared publication
Latest Publications
- Open Access
Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates
To address the challenge of detecting internal defects in medium-thick titanium alloy laser welds, a combined simulation and experimental study on ultrasonic testing was conducted. A finite element model employing a 5 MHz shear wave angle transducer for inspecting titanium alloy welds was established. An ultrasonic testing system was developed, incorporating a DPR300 pulser-receiver (JSR Ultrasonics, Pittsford, NY, USA) and an MSO5204 oscilloscope (RIGOL, Suzhou, China), and was calibrated using standard reference blocks. The inspection results for four prefabricated internal defects at various depths demonstrated that all defects were effectively detected, with the minimum detectable equivalent defect size reaching 1 mm. The measured signal-to-noise ratio (SNR) averaged 17.6 dB, validating the high sensitivity of the proposed system. The mean absolute error for defect localization was 0.438 mm, achieving a positioning accuracy better than 0.5 mm. This study indicates that the pro-posed method enables effective detection and accurate localization of internal defects in titanium alloy laser welds, providing critical technical support for laser welding quality assessment.
Open AccessUltrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates
To address the challenge of detecting internal defects in medium-thick titanium alloy laser welds, a combined simulation and experimental study on ultrasonic testing was conducted. A finite element model employing a 5 MHz shear wave angle transducer for inspecting titanium alloy welds was established. An ultrasonic testing system was developed, incorporating a DPR300 pulser-receiver (JSR Ultrasonics, Pittsford, NY, USA) and an MSO5204 oscilloscope (RIGOL, Suzhou, China), and was calibrated using standard reference blocks. The inspection results for four prefabricated internal defects at various depths demonstrated that all defects were effectively detected, with the minimum detectable equivalent defect size reaching 1 mm. The measured signal-to-noise ratio (SNR) averaged 17.6 dB, validating the high sensitivity of the proposed system. The mean absolute error for defect localization was 0.438 mm, achieving a positioning accuracy better than 0.5 mm. This study indicates that the pro-posed method enables effective detection and accurate localization of internal defects in titanium alloy laser welds, providing critical technical support for laser welding quality assessment.
- Open Access
Research on Ultrasonic Focusing Stacked Transducers for Composite
Most existing carbon fiber composite materials are formed by high-temperature molding of multiple layers of fiber cloth. During the manufacturing and usage processes, materials are prone to defects such as voids, delamination, and inclusions, which seriously threaten their service life and safety performance. Ultrasonic testing is currently a widely adopted method for detecting defects in carbon fiber composite materials. However, existing narrow-pulse ultrasonic transducers often have to sacrifice emission energy to achieve narrow-pulse emission, which results in their limited ability to penetrate thicker carbon fiber composite materials. To address this issue, this paper proposes the design of a focused laminated transducer. By stacking and bonding lead titanate piezoelectric wafers and using a concave lens made of organic glass to focus ultrasonic waves, the emission sound intensity of the ultrasonic transducer is enhanced. The simulation results show that the designed focused double-stack transducer has a directivity gain that is 4.49 dB higher than that of the traditional single-piezoelectric-wafer transducer. The transducer fabricated based on this design has successfully achieved effective detection of internal defects in carbon fiber composite materials.
Open AccessResearch on Ultrasonic Focusing Stacked Transducers for Composite
Most existing carbon fiber composite materials are formed by high-temperature molding of multiple layers of fiber cloth. During the manufacturing and usage processes, materials are prone to defects such as voids, delamination, and inclusions, which seriously threaten their service life and safety performance. Ultrasonic testing is currently a widely adopted method for detecting defects in carbon fiber composite materials. However, existing narrow-pulse ultrasonic transducers often have to sacrifice emission energy to achieve narrow-pulse emission, which results in their limited ability to penetrate thicker carbon fiber composite materials. To address this issue, this paper proposes the design of a focused laminated transducer. By stacking and bonding lead titanate piezoelectric wafers and using a concave lens made of organic glass to focus ultrasonic waves, the emission sound intensity of the ultrasonic transducer is enhanced. The simulation results show that the designed focused double-stack transducer has a directivity gain that is 4.49 dB higher than that of the traditional single-piezoelectric-wafer transducer. The transducer fabricated based on this design has successfully achieved effective detection of internal defects in carbon fiber composite materials.