Haoyu Ming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Haoyu Ming has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Bing Zhou
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication - Bo Sun
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication - Changlong Li
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication Cong Cui
Qilu Hydrogen Energy (Shandong) Development Co., Ltd, Yinan Road, Linzi District, Zibo, China
1 shared publication- Dong Lu
School of Control Science and Engineering, Shandong University, Jinan, China
1 shared publication Fei Ren
1 shared publication
Latest Publications
- 4 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
An Interpretable Fault Diagnosis Method for Hydrogen-Related Equipment in Hydrogen Refueling Stations via TSK Fuzzy System
Equipment such as dispensers and compressors in hydrogen refueling stations operates under prolonged high-pressure and high-frequency conditions. Traditional fault diagnosis methods for hydrogen-related equipment typically rely on data-driven deep learning models.Although these models can achieve high diagnostic accuracy, their “black-box” nature hinders fault cause tracing. Moreover, they cannot verify the reliability of the inference process, which limits their interpretability. To address these issues, this study proposes an interpretable equipment-level fault diagnosis method based on sensor data. First, a fuzzy parameter optimization algorithm is developed to jointly optimize the antecedent and consequent parameters of a multi-rule-based Takagi–Sugeno–Kang (TSK) fuzzy system. The diagnostic accuracy reaches 96.54%. Second, an interpretability matrix is constructed to characterize the relationships between sensor data and fuzzy rules, facilitating fault cause tracing. In addition, an inference-based interpretability method is proposed to reveal the internal logical chain from multi-sensor inputs to the final diagnostic results, thereby verifying the accuracy of the inference process. Finally, a case study is conducted using real multi-sensor monitoring data collected from an operating hydrogen refueling station. The results demonstrate that the proposed method maintains high diagnostic accuracy, while providing clear interpretability in decision-making and inference processes. Thus, the proposed method can support the reliable operation and maintenance of hydrogen energy equipment.
- 4 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
An Interpretable Fault Diagnosis Method for Hydrogen-Related Equipment in Hydrogen Refueling Stations via TSK Fuzzy System
Equipment such as dispensers and compressors in hydrogen refueling stations operates under prolonged high-pressure and high-frequency conditions. Traditional fault diagnosis methods for hydrogen-related equipment typically rely on data-driven deep learning models.Although these models can achieve high diagnostic accuracy, their “black-box” nature hinders fault cause tracing. Moreover, they cannot verify the reliability of the inference process, which limits their interpretability. To address these issues, this study proposes an interpretable equipment-level fault diagnosis method based on sensor data. First, a fuzzy parameter optimization algorithm is developed to jointly optimize the antecedent and consequent parameters of a multi-rule-based Takagi–Sugeno–Kang (TSK) fuzzy system. The diagnostic accuracy reaches 96.54%. Second, an interpretability matrix is constructed to characterize the relationships between sensor data and fuzzy rules, facilitating fault cause tracing. In addition, an inference-based interpretability method is proposed to reveal the internal logical chain from multi-sensor inputs to the final diagnostic results, thereby verifying the accuracy of the inference process. Finally, a case study is conducted using real multi-sensor monitoring data collected from an operating hydrogen refueling station. The results demonstrate that the proposed method maintains high diagnostic accuracy, while providing clear interpretability in decision-making and inference processes. Thus, the proposed method can support the reliable operation and maintenance of hydrogen energy equipment.
- Open Access
- 4 October 2025
- Published by Elsevier in Green Energy and Intelligent Transportation
- Vol. 5 (4)
Fusing coupled degradation mechanisms with machine learning: A multi-fidelity framework for lithium-ion battery lifespan prediction
- 4 October 2025
- Published by Elsevier in Green Energy and Intelligent Transportation
- Vol. 5 (4)
Open AccessFusing coupled degradation mechanisms with machine learning: A multi-fidelity framework for lithium-ion battery lifespan prediction