Oscar Liljeström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oscar Liljeström has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Anja Enell
Swedish Geotechnical Institute (SGI), Olaus Magnus Väg 35, SE-581 93, Linköping, Sweden
4 shared publicationsDahn Rosenquist
Laqua Treatment AB, Siriusvägen 16, SE-296 92, Yngsjö, Sweden
3 shared publicationsLutz Ahrens
Swedish University of Agricultural Sciences (SLU), Department of Aquatic Sciences and Assessment, P. O. Box 7050, SE-750 07, Uppsala, Sweden
3 shared publicationsDan B. Kleja
Swedish Geotechnical Institute (SGI), Olaus Magnus Väg 35, SE-581 93, Linköping, Sweden
2 shared publications- Lutz Ahrens
Department of Aquatic Sciences and Assessment, Swedish University of Agricultural Sciences (SLU), P.O. Box 7050, SE-75007 Uppsala, Sweden
2 shared publications - Anja Enell
Swedish Geotechnical Institute (SGI), SE-581 93 Linköping, Sweden
1 shared publication
Latest Publications
- 15 November 2026
- Vol. 420, 131363
Partitioning and retention of PFAS in a Salix-planted constructed wetland treating foam-fractionated leachate and groundwater.
Per- and polyfluoroalkyl substances (PFAS) are persistent and mobile contaminants frequently detected in landfill leachate and leachate-impacted groundwater, posing risks to environmental and human health. In this study, a pilot-scale (147 m2) subsurface flow constructed wetland (CW), planted with Salix sp. in a peat-biochar substrate, was evaluated as a post-foam fractionation treatment step. Over 176 days, 72.9 m3 of PFAS-contaminated water was treated. The CW reduced the water volume by 48% via evapotranspiration (2.11 L m-2 d-1), but PFAS concentrations did not decrease significantly between influent and effluent. In contrast, a mass balance indicated that 51% (50.7 mg) of the influent PFAS mass was retained within the system. The PFAS retention was primarily associated with the evapotranspiration-driven volume reduction and sorption to the filter substrate, particularly for long-chain PFAS. Short-chain PFAS were retained to a lower extent by the substrate but preferentially accumulated in Salix biomass. Plant uptake accounted for 6.9% of total retained PFAS, with 82-84% of accumulated PFAS located in leaves. No evidence of retranslocation during senescence was observed, indicating potential remobilization via leaf litter unless biomass is managed. The estimated phytoextraction potential of the system for PFAS ranged from 77 to 230 mg ha-1 yr-1, dominated by short-chain compounds. Overall, this CW configuration reduced PFAS mass load rather than aqueous concentrations, suggesting limited suitability as a polishing step. The CW technology could instead be useful as a pre-treatment step prior to advanced treatment, in order to reduce both water volume and contaminant load.
- 15 November 2026
- Vol. 420, 131363
Partitioning and retention of PFAS in a Salix-planted constructed wetland treating foam-fractionated leachate and groundwater.
Per- and polyfluoroalkyl substances (PFAS) are persistent and mobile contaminants frequently detected in landfill leachate and leachate-impacted groundwater, posing risks to environmental and human health. In this study, a pilot-scale (147 m2) subsurface flow constructed wetland (CW), planted with Salix sp. in a peat-biochar substrate, was evaluated as a post-foam fractionation treatment step. Over 176 days, 72.9 m3 of PFAS-contaminated water was treated. The CW reduced the water volume by 48% via evapotranspiration (2.11 L m-2 d-1), but PFAS concentrations did not decrease significantly between influent and effluent. In contrast, a mass balance indicated that 51% (50.7 mg) of the influent PFAS mass was retained within the system. The PFAS retention was primarily associated with the evapotranspiration-driven volume reduction and sorption to the filter substrate, particularly for long-chain PFAS. Short-chain PFAS were retained to a lower extent by the substrate but preferentially accumulated in Salix biomass. Plant uptake accounted for 6.9% of total retained PFAS, with 82-84% of accumulated PFAS located in leaves. No evidence of retranslocation during senescence was observed, indicating potential remobilization via leaf litter unless biomass is managed. The estimated phytoextraction potential of the system for PFAS ranged from 77 to 230 mg ha-1 yr-1, dominated by short-chain compounds. Overall, this CW configuration reduced PFAS mass load rather than aqueous concentrations, suggesting limited suitability as a polishing step. The CW technology could instead be useful as a pre-treatment step prior to advanced treatment, in order to reduce both water volume and contaminant load.
- Open Access
- 11 November 2026
- Published by Elsevier in Journal of Hazardous Materials Advances
Integrated Foam Fractionation and Electrochemical Oxidation for treatment of PFAS in a mixed Groundwater and Landfill Leachate stream
- 11 November 2026
- Published by Elsevier in Journal of Hazardous Materials Advances
Open AccessIntegrated Foam Fractionation and Electrochemical Oxidation for treatment of PFAS in a mixed Groundwater and Landfill Leachate stream
- Open Access
- 28 July 2026
- Published by Elsevier in Environmental Pollution
- Vol. 408, 128851
Evaluating the saturated paste extraction method for determining PFAS solid–liquid partitioning coefficients (Kd) in low-organic-carbon sand aquifers
- 28 July 2026
- Published by Elsevier in Environmental Pollution
- Vol. 408, 128851
Open AccessEvaluating the saturated paste extraction method for determining PFAS solid–liquid partitioning coefficients (Kd) in low-organic-carbon sand aquifers
- Open Access
- 18 February 2026
- Published by Elsevier in Environmental Pollution
- Vol. 395, 127809
Corrigendum to ‘Pilot scale treatment of PFAS-contaminated groundwater in a subsurface flow constructed wetland–evaluating multiple plant species’ [Environ. Pollut. 386 (2025) 127199]
- 18 February 2026
- Published by Elsevier in Environmental Pollution
- Vol. 395, 127809
Open AccessCorrigendum to ‘Pilot scale treatment of PFAS-contaminated groundwater in a subsurface flow constructed wetland–evaluating multiple plant species’ [Environ. Pollut. 386 (2025) 127199]
- 1 January 2026
- Published by Swedish University of Agricultural Sciences
Separation and destruction of PFAS from groundwater using an on-site treatment train
Per- and polyfluoroalkyl substances (PFAS) are persistent and mobile contaminants that pose a considerable risk to groundwater resources. At contaminated sites, such as landfills, PFAS can migrate into groundwater, where their low sorption and high mobility facilitate plume formation and aquifer transport. Addressing this challenge requires an improved understanding of PFAS transport and effective treatment strategies. This thesis investigates PFAS behavior in groundwater systems and evaluated a field-scale integrated treatment train combining foam fractionation (FF), electrochemical oxidation (EO), and a constructed wetland (CW) for remediation of landfill leachate-impacted groundwater. The saturated paste extraction method (SPEM) was evaluated for determining PFAS solid–liquid partitioning coefficients (Kd). SPEM-derived values showed good agreement with field-based estimates and performed better than conventional batch leaching tests (L/S = 1) in low-sorption systems, confirming low Kd values and strong chain-length dependence in sandy, low organic-carbon aquifers. Full-scale FF achieved high separation of long-chain PFAS (>90%). The addition of co-foaming surfactants significantly increased short-chain separation, although separation of ≤C4 perfluoroalkyl carboxylic acids (PFCA) remained limited. The concentrated FF foamate was treated using EO, enabling substantial PFAS degradation, with high fluorine mass balance recovery indicating extensive mineralization. CW, evaluated both as a standalone and polishing step following FF, separated PFAS through substrate sorption and plant uptake, but showed limited effectiveness in reducing aqueous short-chain concentrations. Overall, the results demonstrate that combining FF and EO effectively separated and mineralized long-chain PFAS from groundwater. While co-foaming surfactants improved short-chain separation, additional polishing capable of treating ≤C4 PFCA should be considered. The limited ability of CW to reduce PFAS concentrations, however, limits its suitability for this purpose.
- 1 January 2026
- Published by Swedish University of Agricultural Sciences
Separation and destruction of PFAS from groundwater using an on-site treatment train
Per- and polyfluoroalkyl substances (PFAS) are persistent and mobile contaminants that pose a considerable risk to groundwater resources. At contaminated sites, such as landfills, PFAS can migrate into groundwater, where their low sorption and high mobility facilitate plume formation and aquifer transport. Addressing this challenge requires an improved understanding of PFAS transport and effective treatment strategies. This thesis investigates PFAS behavior in groundwater systems and evaluated a field-scale integrated treatment train combining foam fractionation (FF), electrochemical oxidation (EO), and a constructed wetland (CW) for remediation of landfill leachate-impacted groundwater. The saturated paste extraction method (SPEM) was evaluated for determining PFAS solid–liquid partitioning coefficients (Kd). SPEM-derived values showed good agreement with field-based estimates and performed better than conventional batch leaching tests (L/S = 1) in low-sorption systems, confirming low Kd values and strong chain-length dependence in sandy, low organic-carbon aquifers. Full-scale FF achieved high separation of long-chain PFAS (>90%). The addition of co-foaming surfactants significantly increased short-chain separation, although separation of ≤C4 perfluoroalkyl carboxylic acids (PFCA) remained limited. The concentrated FF foamate was treated using EO, enabling substantial PFAS degradation, with high fluorine mass balance recovery indicating extensive mineralization. CW, evaluated both as a standalone and polishing step following FF, separated PFAS through substrate sorption and plant uptake, but showed limited effectiveness in reducing aqueous short-chain concentrations. Overall, the results demonstrate that combining FF and EO effectively separated and mineralized long-chain PFAS from groundwater. While co-foaming surfactants improved short-chain separation, additional polishing capable of treating ≤C4 PFCA should be considered. The limited ability of CW to reduce PFAS concentrations, however, limits its suitability for this purpose.
- Open Access
- 1 October 2025
- Published by Elsevier in Environmental Pollution
- Vol. 386, 127199
Pilot scale treatment of PFAS-contaminated groundwater in a subsurface flow constructed wetland–evaluating multiple plant species
- 1 October 2025
- Published by Elsevier in Environmental Pollution
- Vol. 386, 127199
Open AccessPilot scale treatment of PFAS-contaminated groundwater in a subsurface flow constructed wetland–evaluating multiple plant species