Dvir Teitelbaum
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dvir Teitelbaum has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Yael Hanein
Tel Aviv University
2 shared publications Daniele Re
Tel Aviv University
1 shared publicationDvir Ben-Dov
School of Electrical and Computer Engineering, Tel Aviv University 1 , Tel Aviv
1 shared publication- Hava Tova Siegelmann
Manning College of Information and Computer Sciences, University of Massachusetts Amherst
1 shared publication - Hila Man
Tel Aviv University
1 shared publication Nitzan Luxembourg
Tel Aviv University
1 shared publication
Latest Publications
- Open Access
- 22 July 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046029
Multimodal quantification of cognitive load using a printed wearable facial bio-potential system
Objective. Cognitive load refers to the amount of mental effort required to process information and perform tasks. It has a strong impact on both learning and task performance and, therefore, plays a central role in cognitive neuroscience, psychology, neurology, human-machine interaction, and education research. Despite its significance, measuring cognitive load is challenging due to its complex and dynamic nature, influenced by task complexity, individual differences, and emotional states. While standard methods are based on subjective self-reports, numerous objective methods have been explored to assess cognitive load, such as electroencephalography (EEG), heart rate variability, and performance-based metrics. Despite these efforts, it remains challenging to objectively measure cognitive load in stationary and even more so in freely moving individuals. Approach. In this study, a wireless wearable system was employed to collect facial bio-potential markers and systematically compare their sensitivity to cognitive load. A dedicated task paradigm was developed and validated to induce graded cognitive load, allowing precise synchronization of physiological signals with task events. Facial muscle activity, eye movements, and brain activity were acquired simultaneously using a single facial electrode array. Main results. Across nine participants, entropy-based features tracked cognitive load more closely than conventional band-power measures. Facial EMG was the most informative modality: a cross-subject (leave-one-subject-out) model predicted the NASA-TLX weighted workload score with a mean Spearman correlation ρ = 0.792 (95% CI [0.747, 0.836]; mean absolute error ≈ 4.3, on a NASA-TLX 0–100 scale), and a single forehead-EMG entropy feature (the EMG-band entropy of forehead channel Ch14, above the right eyebrow) was selected in every cross-subject fold, generalizing across all participants without subject-specific calibration. An EEG-only model carried weaker but genuine cross-subject information ( ρ = 0.739), whereas EOG features did not pass the feature-selection threshold in this seated paradigm. Significance. Facial bio-potentials offer a practical, wearable system for objective cognitive load assessment. An outdoor pilot experiment further demonstrated electrophysiological measures under non-laboratory conditions. These findings offer insights into the suitability of different physiological indicators for assessing cognitive load, particularly the informativeness of facial EMG for seated assessment and the robustness of blink-based measures under ambulatory motion, contributing to the future development of practical measurement techniques in dynamic everyday settings.
- 22 July 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (4) , 046029
Open AccessMultimodal quantification of cognitive load using a printed wearable facial bio-potential system
Objective. Cognitive load refers to the amount of mental effort required to process information and perform tasks. It has a strong impact on both learning and task performance and, therefore, plays a central role in cognitive neuroscience, psychology, neurology, human-machine interaction, and education research. Despite its significance, measuring cognitive load is challenging due to its complex and dynamic nature, influenced by task complexity, individual differences, and emotional states. While standard methods are based on subjective self-reports, numerous objective methods have been explored to assess cognitive load, such as electroencephalography (EEG), heart rate variability, and performance-based metrics. Despite these efforts, it remains challenging to objectively measure cognitive load in stationary and even more so in freely moving individuals. Approach. In this study, a wireless wearable system was employed to collect facial bio-potential markers and systematically compare their sensitivity to cognitive load. A dedicated task paradigm was developed and validated to induce graded cognitive load, allowing precise synchronization of physiological signals with task events. Facial muscle activity, eye movements, and brain activity were acquired simultaneously using a single facial electrode array. Main results. Across nine participants, entropy-based features tracked cognitive load more closely than conventional band-power measures. Facial EMG was the most informative modality: a cross-subject (leave-one-subject-out) model predicted the NASA-TLX weighted workload score with a mean Spearman correlation ρ = 0.792 (95% CI [0.747, 0.836]; mean absolute error ≈ 4.3, on a NASA-TLX 0–100 scale), and a single forehead-EMG entropy feature (the EMG-band entropy of forehead channel Ch14, above the right eyebrow) was selected in every cross-subject fold, generalizing across all participants without subject-specific calibration. An EEG-only model carried weaker but genuine cross-subject information ( ρ = 0.739), whereas EOG features did not pass the feature-selection threshold in this seated paradigm. Significance. Facial bio-potentials offer a practical, wearable system for objective cognitive load assessment. An outdoor pilot experiment further demonstrated electrophysiological measures under non-laboratory conditions. These findings offer insights into the suitability of different physiological indicators for assessing cognitive load, particularly the informativeness of facial EMG for seated assessment and the robustness of blink-based measures under ambulatory motion, contributing to the future development of practical measurement techniques in dynamic everyday settings.
- Open Access
- 1 October 2025
- Published by AIP Publishing in APL Bioengineering
- Vol. 9 (4) , 046103
Finger joint angle and gesture estimation under natural conditions with a soft printed electrode array
Innovative methods for finger gesture recognition have been an active research area, with surface electromyography (sEMG) emerging as a promising approach in human-machine interface applications, especially when visual imaging is impractical. However, sEMG-based gesture recognition is highly susceptible to movement artifacts, individual muscle activation, and changes in hand position, making dynamic gesture recognition challenging. While progress has been made in sEMG data collection and analysis, most studies focus on controlled, static hand positions, limiting real-world applicability. This study integrates a soft wearable sEMG sensor, a Video-Vision-Transform model, and motion sensor-based training to predict finger joint angles and recognize gestures across both static and dynamic hand positions. Despite inter-subject variability, results demonstrate differentiation of finger angles and gestures. For the highly performing subject, recognition accuracy reached 0.85 for static and 0.87 for dynamic settings. This work advances sEMG-based gesture recognition, indicating stable performance across tested static and dynamic conditions, suggesting potential suitability for natural and real-world applications.
- 1 October 2025
- Published by AIP Publishing in APL Bioengineering
- Vol. 9 (4) , 046103
Open AccessFinger joint angle and gesture estimation under natural conditions with a soft printed electrode array
Innovative methods for finger gesture recognition have been an active research area, with surface electromyography (sEMG) emerging as a promising approach in human-machine interface applications, especially when visual imaging is impractical. However, sEMG-based gesture recognition is highly susceptible to movement artifacts, individual muscle activation, and changes in hand position, making dynamic gesture recognition challenging. While progress has been made in sEMG data collection and analysis, most studies focus on controlled, static hand positions, limiting real-world applicability. This study integrates a soft wearable sEMG sensor, a Video-Vision-Transform model, and motion sensor-based training to predict finger joint angles and recognize gestures across both static and dynamic hand positions. Despite inter-subject variability, results demonstrate differentiation of finger angles and gestures. For the highly performing subject, recognition accuracy reached 0.85 for static and 0.87 for dynamic settings. This work advances sEMG-based gesture recognition, indicating stable performance across tested static and dynamic conditions, suggesting potential suitability for natural and real-world applications.