Hongfei Ouyang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hongfei Ouyang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yong Cui
China‐Japan Friendship Hospital (Institute of Clinical Medical Sciences) Chinese Academy of Medical Sciences & Peking Union Medical College Beijing China
3 shared publications Jingkai Xu
Department of Dermatology, China-Japan Friendship Hospital, Beijing, People’s Republic of China
2 shared publicationsJungang Yang
Department of Dermatology, China-Japan Friendship Hospital, Beijing, People’s Republic of China
2 shared publications- Xiaoli Ning
Department of Dermatology, China-Japan Friendship Hospital, Beijing, People’s Republic of China
2 shared publications Jiahui Han
Department of Dermatology China‐Japan Friendship Hospital Beijing China
1 shared publication- Jiahui Han
China‐Japan Friendship Hospital (Institute of Clinical Medical Sciences) Chinese Academy of Medical Sciences & Peking Union Medical College Beijing China
1 shared publication
Latest Publications
- Open Access
- 13 November 2026
- Published by Wiley in Journal of Cosmetic Dermatology
- Vol. 25 (11)
755‐nm Picosecond Laser Versus Intense Pulsed Light for Diffuse Lip Hyperpigmentation: A Prospective, Randomized, Controlled, Evaluator‐Blinded Trial
Background: Lip hyperpigmentation is an aesthetic concern. Evidence supporting light‐based treatments for diffuse lip hyperpigmentation is limited. This study evaluated the efficacy and safety of 755‐nm picosecond laser versus intense pulsed light (IPL) for the treatment of diffuse lip hyperpigmentation. Methods: In this 12‐week, prospective, randomized, controlled, evaluator‐blinded trial, 50 patients were assigned 1:1 to five sessions of either a 755‐nm picosecond laser or IPL at 2‐week intervals. The primary endpoint was the Physician's Global Assessment (PGA) score at Week 12. Secondary endpoints included objective colorimetric parameters (CIE L *, a *, b *), Global Aesthetic Improvement Scale (GAIS), Dermatology Life Quality Index (DLQI), and pain Numerical Rating Scale (NRS). Treatment‐related adverse events were also recorded. Results: Forty‐four patients completed the study (IPL, n = 20; picosecond laser, n = 24). Among completers, the median PGA score at Week 12 was higher in the picosecond laser group than in the IPL group (2.5 [IQR, 2–3] vs. 1.5 [IQR, 1–2.375]; p = 0.007; Hodges–Lehmann estimate, 0.5 PGA points; 95% CI, 0–1.0), and more patients achieved at least moderate improvement (79.2% vs. 45.0%). In sensitivity analyses, statistical significance depended on assumptions about missing PGA outcomes. Objective colorimetric changes did not differ significantly between groups (all p > 0.05). All completers reported improvement on the GAIS, and DLQI scores decreased in both groups. Pain NRS scores were higher in the picosecond laser group ( p < 0.01). Transient scaling occurred in 2 ps‐laser recipients; no adverse events were reported with IPL. Conclusion: Both the 755‐nm picosecond laser and IPL showed improvement in diffuse lip hyperpigmentation, with favorable safety profiles. The picosecond laser showed greater physician‐assessed improvement among completers, whereas IPL was better tolerated. These findings may help guide individualized treatment selection. Trial Registration: Chinese Clinical Trial Registry, ChiCTR2600116083
- 13 November 2026
- Published by Wiley in Journal of Cosmetic Dermatology
- Vol. 25 (11)
Open Access755‐nm Picosecond Laser Versus Intense Pulsed Light for Diffuse Lip Hyperpigmentation: A Prospective, Randomized, Controlled, Evaluator‐Blinded Trial
Background: Lip hyperpigmentation is an aesthetic concern. Evidence supporting light‐based treatments for diffuse lip hyperpigmentation is limited. This study evaluated the efficacy and safety of 755‐nm picosecond laser versus intense pulsed light (IPL) for the treatment of diffuse lip hyperpigmentation. Methods: In this 12‐week, prospective, randomized, controlled, evaluator‐blinded trial, 50 patients were assigned 1:1 to five sessions of either a 755‐nm picosecond laser or IPL at 2‐week intervals. The primary endpoint was the Physician's Global Assessment (PGA) score at Week 12. Secondary endpoints included objective colorimetric parameters (CIE L *, a *, b *), Global Aesthetic Improvement Scale (GAIS), Dermatology Life Quality Index (DLQI), and pain Numerical Rating Scale (NRS). Treatment‐related adverse events were also recorded. Results: Forty‐four patients completed the study (IPL, n = 20; picosecond laser, n = 24). Among completers, the median PGA score at Week 12 was higher in the picosecond laser group than in the IPL group (2.5 [IQR, 2–3] vs. 1.5 [IQR, 1–2.375]; p = 0.007; Hodges–Lehmann estimate, 0.5 PGA points; 95% CI, 0–1.0), and more patients achieved at least moderate improvement (79.2% vs. 45.0%). In sensitivity analyses, statistical significance depended on assumptions about missing PGA outcomes. Objective colorimetric changes did not differ significantly between groups (all p > 0.05). All completers reported improvement on the GAIS, and DLQI scores decreased in both groups. Pain NRS scores were higher in the picosecond laser group ( p < 0.01). Transient scaling occurred in 2 ps‐laser recipients; no adverse events were reported with IPL. Conclusion: Both the 755‐nm picosecond laser and IPL showed improvement in diffuse lip hyperpigmentation, with favorable safety profiles. The picosecond laser showed greater physician‐assessed improvement among completers, whereas IPL was better tolerated. These findings may help guide individualized treatment selection. Trial Registration: Chinese Clinical Trial Registry, ChiCTR2600116083
- Open Access
- 1 March 2026
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dermatology
- Vol. ume 19, 1-10
Bridging Accessibility and Precision: Evaluating the Reliability and Validity of a Smartphone-Based Skin Colorimeter
Background: Accurate quantification of skin color is essential for dermatologic research and clinical practice. Conventional methods rely on specialized equipment, trained operators, and high costs. Smartphone-based technologies provide a promising alternative for accessible skin color assessment. Objective: To evaluate the reliability and validity of the smartphone-based skin colorimeter application, You Look Good Today (YLGTD), for facial skin color assessment compared with two validated devices, VISIA and DermaLab Combo. Methods: A total of 105 Chinese participants with healthy facial skin were enrolled. Cheek skin color measurements were obtained using YLGTD (user self-assessment and physician measurement modes), VISIA, and DermaLab Combo. Inter-rater reliability between YLGTD measurement modes was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Criterion validity was evaluated using Pearson’s correlation coefficients between YLGTD measurements and the reference devices. Results: YLGTD demonstrated excellent inter-rater reliability across all parameters (ICC: 0.85– 0.95). Bland–Altman analysis showed small biases between the two measurement modes for the L, a, and b (− 0.05, 0.18, and − 0.99, respectively). For criterion validity, YLGTD in user mode showed strong correlations with DermaLab Combo for L* (r = 0.71), individual typology angle (ITA°, r = − 0.81), and chroma (C*, r = 0.78), and moderate correlations for b* (r = 0.59) and hue (h°, r = 0.57). Correlations were consistently stronger in physician mode (L*: r = 0.77; b*: r = 0.75; C*: r = 0.84; ITA°: r = − 0.87). VISIA showed a stronger correlation for a* (r = 0.55) but weaker correlations for L* (r = 0.56) and ITA° (r = − 0.68) compared with YLGTD. Conclusion: The smartphone-based application YLGTD demonstrated excellent reliability and acceptable validity for facial skin color assessment, particularly for pigmentation-related parameters. Its standardized measurement workflow and integrated algorithms enable consistent skin color evaluation across devices and real-world conditions, providing a convenient and cost-effective approach for objective skin color assessment.
- 1 March 2026
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dermatology
- Vol. ume 19, 1-10
Open AccessBridging Accessibility and Precision: Evaluating the Reliability and Validity of a Smartphone-Based Skin Colorimeter
Background: Accurate quantification of skin color is essential for dermatologic research and clinical practice. Conventional methods rely on specialized equipment, trained operators, and high costs. Smartphone-based technologies provide a promising alternative for accessible skin color assessment. Objective: To evaluate the reliability and validity of the smartphone-based skin colorimeter application, You Look Good Today (YLGTD), for facial skin color assessment compared with two validated devices, VISIA and DermaLab Combo. Methods: A total of 105 Chinese participants with healthy facial skin were enrolled. Cheek skin color measurements were obtained using YLGTD (user self-assessment and physician measurement modes), VISIA, and DermaLab Combo. Inter-rater reliability between YLGTD measurement modes was assessed using intraclass correlation coefficients (ICC) and Bland-Altman analysis. Criterion validity was evaluated using Pearson’s correlation coefficients between YLGTD measurements and the reference devices. Results: YLGTD demonstrated excellent inter-rater reliability across all parameters (ICC: 0.85– 0.95). Bland–Altman analysis showed small biases between the two measurement modes for the L, a, and b (− 0.05, 0.18, and − 0.99, respectively). For criterion validity, YLGTD in user mode showed strong correlations with DermaLab Combo for L* (r = 0.71), individual typology angle (ITA°, r = − 0.81), and chroma (C*, r = 0.78), and moderate correlations for b* (r = 0.59) and hue (h°, r = 0.57). Correlations were consistently stronger in physician mode (L*: r = 0.77; b*: r = 0.75; C*: r = 0.84; ITA°: r = − 0.87). VISIA showed a stronger correlation for a* (r = 0.55) but weaker correlations for L* (r = 0.56) and ITA° (r = − 0.68) compared with YLGTD. Conclusion: The smartphone-based application YLGTD demonstrated excellent reliability and acceptable validity for facial skin color assessment, particularly for pigmentation-related parameters. Its standardized measurement workflow and integrated algorithms enable consistent skin color evaluation across devices and real-world conditions, providing a convenient and cost-effective approach for objective skin color assessment.
- 30 September 2025
- Published by Wiley in Pigment Cell & Melanoma Research
- Vol. 38 (6) , e70057
Noninvasive Assessment of Melasma Pathological Features: Side‐By‐Side Comparison of Two‐Photon Microscopy and Reflectance Confocal Microscopy
Melasma, a refractory hyperpigmentation disorder, requires noninvasive tools for accurate pathological assessment. This study compared two‐photon microscopy (TPM) and reflectance confocal microscopy (RCM) for the in vivo characterization of melasma pathology. In this cross‐sectional study, TPM and RCM features and imaging clarity were evaluated in 130 melasma patients. Spearman correlation analyses were performed between TPM‐quantified epidermal melanin, the melanin index (MI), and the individual typology angle (ITA). Features were also compared between active and stable disease stages. TPM and RCM showed substantial agreement in detecting increased epidermal melanin (κ = 0.651), activated melanocytes at the dermal‐epidermal junction (DEJ) (κ = 0.711), and flattened rete ridges (κ = 0.691) (all p < 0.001). TPM excelled in visualizing intracellular melanin distribution, pendulous melanocytes under the DEJ, and solar elastosis, while RCM better identified activated melanocytes at the DEJ. TPM‐quantified epidermal melanin content correlated positively with MI and negatively with ITA. RCM‐detected dermal inflammatory cells were more prevalent in active than in stable melasma. In conclusion, TPM and RCM synergistically capture critical melasma features, with TPM assessing disease severity via epidermal melanin quantification, whereas RCM reflects disease activity by detecting inflammatory cells. This provides clinicians with tailored imaging tools for precision management.
- 30 September 2025
- Published by Wiley in Pigment Cell & Melanoma Research
- Vol. 38 (6) , e70057
Noninvasive Assessment of Melasma Pathological Features: Side‐By‐Side Comparison of Two‐Photon Microscopy and Reflectance Confocal Microscopy
Melasma, a refractory hyperpigmentation disorder, requires noninvasive tools for accurate pathological assessment. This study compared two‐photon microscopy (TPM) and reflectance confocal microscopy (RCM) for the in vivo characterization of melasma pathology. In this cross‐sectional study, TPM and RCM features and imaging clarity were evaluated in 130 melasma patients. Spearman correlation analyses were performed between TPM‐quantified epidermal melanin, the melanin index (MI), and the individual typology angle (ITA). Features were also compared between active and stable disease stages. TPM and RCM showed substantial agreement in detecting increased epidermal melanin (κ = 0.651), activated melanocytes at the dermal‐epidermal junction (DEJ) (κ = 0.711), and flattened rete ridges (κ = 0.691) (all p < 0.001). TPM excelled in visualizing intracellular melanin distribution, pendulous melanocytes under the DEJ, and solar elastosis, while RCM better identified activated melanocytes at the DEJ. TPM‐quantified epidermal melanin content correlated positively with MI and negatively with ITA. RCM‐detected dermal inflammatory cells were more prevalent in active than in stable melasma. In conclusion, TPM and RCM synergistically capture critical melasma features, with TPM assessing disease severity via epidermal melanin quantification, whereas RCM reflects disease activity by detecting inflammatory cells. This provides clinicians with tailored imaging tools for precision management.