Ahmed M Eltohamy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed M Eltohamy has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Abdelrahman A. Elsherief
Department of Civil Engineering Faculty of Engineering, Aswan University and Nahda University, Aswan and Beni Suef, Egypt
2 shared publications - Ali G. Hafez
Seismology Department, National Research Institute of Astronomy and Geophysics (NRIAG), Helwan 11421, Egypt Control and Computer Department, College of Engineering, Almaaqal University, Basrah, Iraq. R&D Division, LTLab, Inc
2 shared publications - Hany Madkour
Faculty of Engineering, Aswan University, Aswan 81528, Egypt
2 shared publications - Safia Mohamed Khodary
Civil Engineering Department, Faculty of Engineeing, Aswan University, Aswan, Egypt
2 shared publications - ِaHmed M Reda
Department of Mechanical Engineering Faculty of Energy Engineering Aswan university Aswan, Egypt
2 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by Egyptian Knowledge Bank in International Journal of Applied Energy Systems
- Vol. 7 (2) , 69-78
Evaluation of Inlet Temperature Impacts on Heat Transfer and Soil Thermal Behavior in Horizontal Spiral Ground Heat Exchangers
This study investigates the thermal performance of a Horizontal Spiral Ground Heat Exchanger (HSGHE) under varying inlet temperatures in hot climates, with a focus on ground source heat pumps (GSHPs) as a sustainable energy solution. The experimental setup utilized a spiral tube embedded in dry sand placed within a controlled environment. The results indicated that inlet temperature significantly influences heat exchange rates (HER). Higher inlet temperatures initially resulted in higher HER, but these values declined over time due to the diminishing temperature gradient between the circulating fluid and surrounding soil. For an inlet temperature of 50°C, reductions in HER of approximately 40% and 63% were observed at 45°C and 40°C, respectively. After six hours, HER decreased by 58%, 50%, and 36% for 50°C, 45°C, and 40°C, respectively. These findings highlight the long-term impact of inlet temperature on system efficiency, where higher initial HER does not always correlate with sustained high performance.The study also assessed soil thermal dispersion and found that heat dissipation was highly localized. For 50°C, the thermal effect extended up to 0.4 meters, while at 45°C, it diminished to 0.3 meters, and at 40°C, the effect was minimal beyond a short distance. Based on these results, an optimal spacing of 0.8 meters between exchangers is recommended to minimize thermal interference and maximize system efficiency. These findings underscore the importance of temperature gradients and operational parameters in optimizing ground heat exchanger performance in hot climates.
- 1 July 2025
- Published by Egyptian Knowledge Bank in International Journal of Applied Energy Systems
- Vol. 7 (2) , 69-78
Open AccessEvaluation of Inlet Temperature Impacts on Heat Transfer and Soil Thermal Behavior in Horizontal Spiral Ground Heat Exchangers
This study investigates the thermal performance of a Horizontal Spiral Ground Heat Exchanger (HSGHE) under varying inlet temperatures in hot climates, with a focus on ground source heat pumps (GSHPs) as a sustainable energy solution. The experimental setup utilized a spiral tube embedded in dry sand placed within a controlled environment. The results indicated that inlet temperature significantly influences heat exchange rates (HER). Higher inlet temperatures initially resulted in higher HER, but these values declined over time due to the diminishing temperature gradient between the circulating fluid and surrounding soil. For an inlet temperature of 50°C, reductions in HER of approximately 40% and 63% were observed at 45°C and 40°C, respectively. After six hours, HER decreased by 58%, 50%, and 36% for 50°C, 45°C, and 40°C, respectively. These findings highlight the long-term impact of inlet temperature on system efficiency, where higher initial HER does not always correlate with sustained high performance.The study also assessed soil thermal dispersion and found that heat dissipation was highly localized. For 50°C, the thermal effect extended up to 0.4 meters, while at 45°C, it diminished to 0.3 meters, and at 40°C, the effect was minimal beyond a short distance. Based on these results, an optimal spacing of 0.8 meters between exchangers is recommended to minimize thermal interference and maximize system efficiency. These findings underscore the importance of temperature gradients and operational parameters in optimizing ground heat exchanger performance in hot climates.
- Open Access
- 1 July 2025
- Published by Egyptian Knowledge Bank in International Journal of Applied Energy Systems
- Vol. 7 (2) , 61-68
Experimental Study on the Effect of Flow Rate on the Performance of Horizontal Ground Heat Exchangers in Sand Soil during Hot Climates
Ground heat exchangers (GHE) are extensively utilized in geothermal heating and cooling systems due to their efficiency and sustainability. This research presents an experimental study on the effect of flow rate on the performance of horizontal ground heat exchangers (HGHE) in sand soil. The study investigates how varying flow rates impact heat exchange efficiency, soil temperature distribution, and thermal performance during hot climates. A laboratory setup was developed to simulate real-world conditions, incorporating a spiral coil heat exchanger buried in sand soil. Experiments were conducted at different flow rates (5 L/min, 6 L/min, and 7 L/min), while monitoring temperature variations in both the soil and circulating fluid. The results indicate that increasing the flow rate enhances convective heat transfer, leading to a 31.8% improvement in heat exchange rate (HER) when increasing from 5 L/min to 7 L/min. However, the benefits diminish over time, with HER decreasing by approximately 55% within the first three hours as thermal equilibrium is approached.In terms of soil temperature distribution, the study found that heat dissipation in the horizontal direction becomes negligible beyond 0.4 meters, while in the vertical direction, temperature influence fades beyond 0.4 meters. At lower flow rates, soil temperature gain increased by up to 38% compared to higher flow rates, due to prolonged heat retention. This study focuses the importance of optimizing flow rates to balance energy efficiency and thermal performance in ground heat exchangers
- 1 July 2025
- Published by Egyptian Knowledge Bank in International Journal of Applied Energy Systems
- Vol. 7 (2) , 61-68
Open AccessExperimental Study on the Effect of Flow Rate on the Performance of Horizontal Ground Heat Exchangers in Sand Soil during Hot Climates
Ground heat exchangers (GHE) are extensively utilized in geothermal heating and cooling systems due to their efficiency and sustainability. This research presents an experimental study on the effect of flow rate on the performance of horizontal ground heat exchangers (HGHE) in sand soil. The study investigates how varying flow rates impact heat exchange efficiency, soil temperature distribution, and thermal performance during hot climates. A laboratory setup was developed to simulate real-world conditions, incorporating a spiral coil heat exchanger buried in sand soil. Experiments were conducted at different flow rates (5 L/min, 6 L/min, and 7 L/min), while monitoring temperature variations in both the soil and circulating fluid. The results indicate that increasing the flow rate enhances convective heat transfer, leading to a 31.8% improvement in heat exchange rate (HER) when increasing from 5 L/min to 7 L/min. However, the benefits diminish over time, with HER decreasing by approximately 55% within the first three hours as thermal equilibrium is approached.In terms of soil temperature distribution, the study found that heat dissipation in the horizontal direction becomes negligible beyond 0.4 meters, while in the vertical direction, temperature influence fades beyond 0.4 meters. At lower flow rates, soil temperature gain increased by up to 38% compared to higher flow rates, due to prolonged heat retention. This study focuses the importance of optimizing flow rates to balance energy efficiency and thermal performance in ground heat exchangers