Johanna Bayer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Johanna Bayer has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Amar Gupta
Division of Abdominal Transplantation, Department of Surgery, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX
5 shared publications - Anji Wall
Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, Dallas, TX, USA
5 shared publications - Eric Martinez
Division of Abdominal Transplantation, Department of Surgery, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX
5 shared publications - Giuliano Testa
Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, Dallas, TX, USA
5 shared publications - Juan Sebastian Danobeitia
Annette C. and Harold C. Simmons Transplant Institute, Baylor University Medical Center, Dallas, Texas
4 shared publications - Seung Hee Lee
Division of Abdominal Transplantation, Department of Surgery, Baylor University Medical Center, Baylor Scott and White Health, Dallas, TX
4 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 12 (10) , e2006
Intra-abdominal Versus Descending Thoracic Cannulation Techniques for Abdominal Normothermic Regional Perfusion
Background.: Abdominal normothermic regional perfusion (A-NRP) is postmortem perfusion of organs in the abdominal cavity and can be performed using multiple approaches, including femoral, intra-abdominal, and thoracic. Our program began with surgeons performing intra-abdominal cannulations with mechanical or balloon occlusion of the descending thoracic aorta for A-NRP procedures. Recently, we developed a novel technique using the descending thoracic aorta for arterial cannulation with right atrial venous drainage. Methods.: All A-NRP cases performed by Regional Perfusion Services from July 1, 2024, to June 30, 2025, were retrospectively reviewed. Intraoperative parameters were collected for comparison. Results.: During the study period, 28 intra-abdominal normothermic regional perfusion (IA-NRP) cannulations and 47 descending thoracic normothermic regional perfusion (DT-NRP) cannulations were performed by 16 surgeons. Median cannulation time was shorter in the DT-NRP cohort (8.5 versus 10.0 min; P = 0.016). Median time on NRP was shorter in the IA-NRP cohort (61.5 versus 91.0 min; P = 0.006). The median decrease in lactate was larger in the DT-NRP cohort (2.9 versus 2.3 mmol/dL; P = 0.024). The median number of transfusions used was higher in the IA-NRP cohort (3.0 versus 0.0; P < 0.001). The learning curves show a quicker descent in time and a lower nadir for the DT-NRP cases, indicating this technique may have a quicker learning curve and be a more efficient approach to cannulation. Conclusions.: DT-NRP cannulation can be implemented for A-NRP with a quick learning curve, providing an additional cannulation option to the IA-NRP approach.
- 9 September 2026
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 12 (10) , e2006
Open AccessIntra-abdominal Versus Descending Thoracic Cannulation Techniques for Abdominal Normothermic Regional Perfusion
Background.: Abdominal normothermic regional perfusion (A-NRP) is postmortem perfusion of organs in the abdominal cavity and can be performed using multiple approaches, including femoral, intra-abdominal, and thoracic. Our program began with surgeons performing intra-abdominal cannulations with mechanical or balloon occlusion of the descending thoracic aorta for A-NRP procedures. Recently, we developed a novel technique using the descending thoracic aorta for arterial cannulation with right atrial venous drainage. Methods.: All A-NRP cases performed by Regional Perfusion Services from July 1, 2024, to June 30, 2025, were retrospectively reviewed. Intraoperative parameters were collected for comparison. Results.: During the study period, 28 intra-abdominal normothermic regional perfusion (IA-NRP) cannulations and 47 descending thoracic normothermic regional perfusion (DT-NRP) cannulations were performed by 16 surgeons. Median cannulation time was shorter in the DT-NRP cohort (8.5 versus 10.0 min; P = 0.016). Median time on NRP was shorter in the IA-NRP cohort (61.5 versus 91.0 min; P = 0.006). The median decrease in lactate was larger in the DT-NRP cohort (2.9 versus 2.3 mmol/dL; P = 0.024). The median number of transfusions used was higher in the IA-NRP cohort (3.0 versus 0.0; P < 0.001). The learning curves show a quicker descent in time and a lower nadir for the DT-NRP cases, indicating this technique may have a quicker learning curve and be a more efficient approach to cannulation. Conclusions.: DT-NRP cannulation can be implemented for A-NRP with a quick learning curve, providing an additional cannulation option to the IA-NRP approach.
- Open Access
- 22 August 2026
- Published by Elsevier in Journal of Liver Transplantation
- Vol. 24
A single-center comparison of liver grafts from donation after brain death and donation after circulatory death with normothermic regional perfusion
- 22 August 2026
- Published by Elsevier in Journal of Liver Transplantation
- Vol. 24
Open AccessA single-center comparison of liver grafts from donation after brain death and donation after circulatory death with normothermic regional perfusion
- Open Access
- 23 October 2025
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 11 (11) , e1870
Utilization of Liver Grafts From Donation After Circulatory Death Donors on Extracorporeal Membrane Oxygenation Support Using Normothermic Regional Perfusion
Background.: Normothermic regional perfusion (NRP) is an organ procurement technique developed for donation after circulatory death (DCD). NRP is associated with better liver transplant outcomes and allows increased risk thresholds for medically complex DCD donors. DCD donors on extracorporeal membrane oxygenation (ECMO) are a category of medically complex donors lacking significant reported experience. Objectives.: This brief report describes the utilization of liver grafts from ECMO-DCD donors using an NRP procurement technique. Methods.: Retrospective analysis of donor and recipient outcomes in 3 cases following abdominal DCD-NRP with ECMO cannula exchange to an NRP circuit. Existing cannulas and tubing can be used for NRP inflow, outflow, or both depending on the configuration. Results.: All donors were older than the age of 50 y and had a functional warm ischemia time of <30 min. NRP duration ranged from 66 to 134 min. All 3 donors demonstrated lactate clearance while on NRP. Recipient age ranged from 52 to 68 and model for end-stage liver disease scores were 22, 26, and 7. All had a 1-d intensive care unit stay and 5- to 7-d total hospital length of stay. One of the 3 recipients had a biliary anastomotic stricture. Conclusions.: This report demonstrates the technical and clinical feasibility of liver transplantation from ECMO-DCD-NRP donors. Preoperative planning for the utilization of existing cannulas, the addition of needed inflow or outflow, and circuit exchange logistics is essential for a smooth transition to NRP in these cases.
- 23 October 2025
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 11 (11) , e1870
Open AccessUtilization of Liver Grafts From Donation After Circulatory Death Donors on Extracorporeal Membrane Oxygenation Support Using Normothermic Regional Perfusion
Background.: Normothermic regional perfusion (NRP) is an organ procurement technique developed for donation after circulatory death (DCD). NRP is associated with better liver transplant outcomes and allows increased risk thresholds for medically complex DCD donors. DCD donors on extracorporeal membrane oxygenation (ECMO) are a category of medically complex donors lacking significant reported experience. Objectives.: This brief report describes the utilization of liver grafts from ECMO-DCD donors using an NRP procurement technique. Methods.: Retrospective analysis of donor and recipient outcomes in 3 cases following abdominal DCD-NRP with ECMO cannula exchange to an NRP circuit. Existing cannulas and tubing can be used for NRP inflow, outflow, or both depending on the configuration. Results.: All donors were older than the age of 50 y and had a functional warm ischemia time of <30 min. NRP duration ranged from 66 to 134 min. All 3 donors demonstrated lactate clearance while on NRP. Recipient age ranged from 52 to 68 and model for end-stage liver disease scores were 22, 26, and 7. All had a 1-d intensive care unit stay and 5- to 7-d total hospital length of stay. One of the 3 recipients had a biliary anastomotic stricture. Conclusions.: This report demonstrates the technical and clinical feasibility of liver transplantation from ECMO-DCD-NRP donors. Preoperative planning for the utilization of existing cannulas, the addition of needed inflow or outflow, and circuit exchange logistics is essential for a smooth transition to NRP in these cases.
- Open Access
- 3 October 2025
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 11 (11) , e1858
The Landscape of In Situ and Ex Situ Machine Perfusion Utilization for Liver Grafts From Noncardiac Donation After Circulatory Death Donors in the Early era of Machine Perfusion in the United States
Background.: Donation after circulatory death (DCD) is the major contributor to the growth in deceased organ donation in the United States. Normothermic regional perfusion (NRP) and ex situ machine perfusion (es-MP) have been vital for improving organ assessment and preservation in DCD donor organs. The procurement procedure and storage strategy for noncardiac donors were determined by liver transplant centers in the early era of machine perfusion in the United States. In this study, we analyzed the landscape of liver utilization from noncardiac DCD donors in the United States during the early era of machine perfusion. Methods.: All adult (18 y and older) DCD donors in the United States for which the heart was not used for transplantation from October 1, 2020, to December 31, 2023, were compared using procurement technique (NRP versus super rapid recovery [SRR]) and storage strategy (ex situ machine perfusion [es-MP] versus static cold storage). Results.: One hundred fifty-six livers were transplanted from 284 NRP donors (55% utilization) versus 2497 liver transplants from 9132 SRR donors (27% utilization). Es-MP was used in 19% (n = 30) of liver NRP cases versus 28% (n = 695) of liver SRR cases. Eight hundred fifty-one liver grafts (32%) were exposed to NRP, es-MP, or both. Conclusions.: Given the variation in liver graft management, further research needs to be conducted on the optimal strategies for using technologies such as NRP and es-MP in liver transplantation in the United States; better data collection is necessary to support this research and additional strategies are required to increase access to machine perfusion on a national level are needed.
- 3 October 2025
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 11 (11) , e1858
Open AccessThe Landscape of In Situ and Ex Situ Machine Perfusion Utilization for Liver Grafts From Noncardiac Donation After Circulatory Death Donors in the Early era of Machine Perfusion in the United States
Background.: Donation after circulatory death (DCD) is the major contributor to the growth in deceased organ donation in the United States. Normothermic regional perfusion (NRP) and ex situ machine perfusion (es-MP) have been vital for improving organ assessment and preservation in DCD donor organs. The procurement procedure and storage strategy for noncardiac donors were determined by liver transplant centers in the early era of machine perfusion in the United States. In this study, we analyzed the landscape of liver utilization from noncardiac DCD donors in the United States during the early era of machine perfusion. Methods.: All adult (18 y and older) DCD donors in the United States for which the heart was not used for transplantation from October 1, 2020, to December 31, 2023, were compared using procurement technique (NRP versus super rapid recovery [SRR]) and storage strategy (ex situ machine perfusion [es-MP] versus static cold storage). Results.: One hundred fifty-six livers were transplanted from 284 NRP donors (55% utilization) versus 2497 liver transplants from 9132 SRR donors (27% utilization). Es-MP was used in 19% (n = 30) of liver NRP cases versus 28% (n = 695) of liver SRR cases. Eight hundred fifty-one liver grafts (32%) were exposed to NRP, es-MP, or both. Conclusions.: Given the variation in liver graft management, further research needs to be conducted on the optimal strategies for using technologies such as NRP and es-MP in liver transplantation in the United States; better data collection is necessary to support this research and additional strategies are required to increase access to machine perfusion on a national level are needed.
- Open Access
- 29 April 2021
- Published by Wiley in Clinical Transplantation
- Vol. 35 (7) , e14331
Selective screening imaging of the aortoiliac arterial system in kidney transplant candidates with non‐contrast pelvic computed tomography
Non‐contrast pelvic computed tomography (CT) can detect severe iliac artery calcifications that present technical contraindications to kidney transplantation (TCT). We screened 454 asymptomatic patients with a history of any of the following: hemodialysis >10 years, diabetes mellitus >20 years, coronary artery disease (CAD) with percutaneous or surgical interventions, carotid disease, diabetes with below‐/above‐knee amputations, and heart‐kidney transplantation candidacy. Patients with normal dorsalis pedis and/or tibialis posterior pulses were not screened. A total of 8.4% had severe calcifications with TCT; CT determined laterality for implantation in 13.9%. No patients with the following characteristics were classified as TCT: age 10 years, carotid arterial disease, prior lower extremity amputation, or heart‐kidney transplantation candidacy. CAD was associated with TCT in univariate though not multivariate analysis. Limiting screening to patients >40 years, with DM >20 years, or with CAD, 9.8% had a TCT and CT determined transplant laterality in 14.2%. Screening for severe iliac artery calcifications is useful for selected kidney transplantation candidates over age 40. It can assist with laterality choice or surgeon determination of TCT. Cost and radiation exposure risks should be weighed against the morbidity risks from unnecessary surgery.
- 29 April 2021
- Published by Wiley in Clinical Transplantation
- Vol. 35 (7) , e14331
Open AccessSelective screening imaging of the aortoiliac arterial system in kidney transplant candidates with non‐contrast pelvic computed tomography
Non‐contrast pelvic computed tomography (CT) can detect severe iliac artery calcifications that present technical contraindications to kidney transplantation (TCT). We screened 454 asymptomatic patients with a history of any of the following: hemodialysis >10 years, diabetes mellitus >20 years, coronary artery disease (CAD) with percutaneous or surgical interventions, carotid disease, diabetes with below‐/above‐knee amputations, and heart‐kidney transplantation candidacy. Patients with normal dorsalis pedis and/or tibialis posterior pulses were not screened. A total of 8.4% had severe calcifications with TCT; CT determined laterality for implantation in 13.9%. No patients with the following characteristics were classified as TCT: age 10 years, carotid arterial disease, prior lower extremity amputation, or heart‐kidney transplantation candidacy. CAD was associated with TCT in univariate though not multivariate analysis. Limiting screening to patients >40 years, with DM >20 years, or with CAD, 9.8% had a TCT and CT determined transplant laterality in 14.2%. Screening for severe iliac artery calcifications is useful for selected kidney transplantation candidates over age 40. It can assist with laterality choice or surgeon determination of TCT. Cost and radiation exposure risks should be weighed against the morbidity risks from unnecessary surgery.
- 1 June 2013
- Published by Elsevier in Journal of Surgical Research
- Vol. 182 (2) , 192-197
Diagnosis of anastomotic leak: Electrolyte detection versus barium fluoroscopy
- 1 June 2013
- Published by Elsevier in Journal of Surgical Research
- Vol. 182 (2) , 192-197
Diagnosis of anastomotic leak: Electrolyte detection versus barium fluoroscopy