Jianda Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jianda Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Baojun Hui
China Southern Power Grid Electric Power Research Institute, Guangzhou 510663, China
1 shared publication - Linjie Zhao
High Voltage Technology Institute, CSG Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
1 shared publication - Shuai Hou
CSG Electric Power Research Institute Co., Ltd
1 shared publication - Tao Han
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
1 shared publication - Wenbo Zhu
China Southern Power Grid Electric Power Research Institute, Guangzhou, Guangdong, China
1 shared publication
Latest Publications
- Open Access
Frequency Domain Reflectometry for Power Cable Defect Localization: A Comparative Study of FFT and IFFT Methods
At present, the development of power cables shows three notable trends: higher voltage, longer distance and more complex environments. Against this backdrop, the limitations of traditional detection techniques in locating local defects have become increasingly apparent. Frequency Domain Reflectometry (FDR) has garnered sustained research attention both domestically and internationally due to its high sensitivity and accuracy in detecting localized defects. This paper aims to compare the defect localization effectiveness of the Fast Fourier Transform (FFT) method and the Inverse Fast Fourier Transform (IFFT) method within FDR. First, the differences between the two methods are analyzed from a theoretical perspective. Then, field tests are conducted on cables of varying voltage levels and lengths, with comparisons made using parameters such as full width at half maximum (FWHM) and signal-to-noise ratio (SNR). The results indicate that the FFT method is more suitable for low-interference or short cables, while the IFFT method is more suitable for high-noise, high-resolution, or long cables.
Open AccessFrequency Domain Reflectometry for Power Cable Defect Localization: A Comparative Study of FFT and IFFT Methods
At present, the development of power cables shows three notable trends: higher voltage, longer distance and more complex environments. Against this backdrop, the limitations of traditional detection techniques in locating local defects have become increasingly apparent. Frequency Domain Reflectometry (FDR) has garnered sustained research attention both domestically and internationally due to its high sensitivity and accuracy in detecting localized defects. This paper aims to compare the defect localization effectiveness of the Fast Fourier Transform (FFT) method and the Inverse Fast Fourier Transform (IFFT) method within FDR. First, the differences between the two methods are analyzed from a theoretical perspective. Then, field tests are conducted on cables of varying voltage levels and lengths, with comparisons made using parameters such as full width at half maximum (FWHM) and signal-to-noise ratio (SNR). The results indicate that the FFT method is more suitable for low-interference or short cables, while the IFFT method is more suitable for high-noise, high-resolution, or long cables.