Maryam Ghandhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maryam Ghandhari has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Armin Doostparast
Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
18 shared publications - Alireza Eslampoor
Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
8 shared publications - Farbod Semnani
School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
6 shared publications - Ali Ahmadi
Student Research Committee, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
5 shared publications - Amir Hossein Khosronejad
Student Research Committee, Mazandaran University of Medical Sciences, Sari, Iran
5 shared publications - Sajjad Sadeghpour
Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
4 shared publications
Latest Publications
- 15 October 2026
- Published by Wolters Kluwer Health in Cornea
Methodological Considerations Regarding Repeatability of Epithelial Thickness Mapping in Normal and Keratoconus Eyes Using a Novel Hybrid Scheimpflug–Optical Coherence Tomography Device
Was not provided for this article.
- 15 October 2026
- Published by Wolters Kluwer Health in Cornea
Methodological Considerations Regarding Repeatability of Epithelial Thickness Mapping in Normal and Keratoconus Eyes Using a Novel Hybrid Scheimpflug–Optical Coherence Tomography Device
Was not provided for this article.
- Open Access
- 12 September 2026
- Published by Elsevier in European Journal of Radiology Open
- Vol. 17
MRI-based radiomics analysis and machine learning in the differentiation of endometriomas from hemorrhagic ovarian cysts
- 12 September 2026
- Published by Elsevier in European Journal of Radiology Open
- Vol. 17
Open AccessMRI-based radiomics analysis and machine learning in the differentiation of endometriomas from hemorrhagic ovarian cysts
- Open Access
- 8 September 2026
- Published by Springer Nature in BMC Pediatrics
Utility of ultrasonography in distinguishing pediatric small bowel and ileocolic intussusceptions: a clinicoradiological study
Background: Intussusception is a common pediatric abdominal emergency, categorized as small bowel intussusception (SBI) or ileocolic intussusception (ICI). The management of SBI and ICI differs significantly. Therefore, timely diagnosis and distinguishing between SBI and ICI are essential. This study aimed to determine and compare the diagnostic value of clinicoradiological characteristics in differentiating SBI from ICI. Materials and methods: One hundred one children (55 with SBI and 46 with ICI) with clinical suspicion of intussusception were enrolled. All clinicoradiological characteristics were compared between SBI and ICI. Univariate Logistic regression analysis was also used to assess the strength of associations. Receiver operating characteristic curves were constructed to determine optimal cut-off values, and the area under the curve (AUC) was calculated to evaluate diagnostic performance. Results: Age, sex, vomiting, and diarrhea were not significantly different between ICI and SBI cases ( P > 0.05). In contrast, abdominal pain, bloody stool, lymph nodes within the intussusception, free peritoneal fluid, length of intussusception (AUC: 0.94, sensitivity = 87%, specificity = 87%, cut-off point = 40 mm), lesion diameter (AUC: 0.96, sensitivity = 91%, specificity = 89%, cut-off point = 25 mm), fat core diameter (AUC: 0.91, sensitivity = 85%, specificity = 84%, cut-off point = 7 mm), outer wall thickness (AUC: 0.61, sensitivity = 74%, specificity = 53%, cut-off point = 5 mm), core-to-wall index (AUC: 0.93, sensitivity = 91%, specificity = 89%, cut-off point = 1.33), and core-to-wall index > 1 (AUC: 0.87, sensitivity = 93%, specificity = 80%, cut-off point = 1) were significantly higher in ICI than SBI cases ( P < 0.05). Conclusion: Our findings suggested that US is a reliable tool and demonstrates very high diagnostic utility in distinguishing SBI from ICI. Among them, the lesion diameter, length of intussusception, and core-to-wall index were the most useful variables. Therefore, ultrasound findings could assist clinicians beyond clinical symptoms and physical examination findings in an effective diagnosis and management of intussusception and in improving clinical decision-making.
- 8 September 2026
- Published by Springer Nature in BMC Pediatrics
Open AccessUtility of ultrasonography in distinguishing pediatric small bowel and ileocolic intussusceptions: a clinicoradiological study
Background: Intussusception is a common pediatric abdominal emergency, categorized as small bowel intussusception (SBI) or ileocolic intussusception (ICI). The management of SBI and ICI differs significantly. Therefore, timely diagnosis and distinguishing between SBI and ICI are essential. This study aimed to determine and compare the diagnostic value of clinicoradiological characteristics in differentiating SBI from ICI. Materials and methods: One hundred one children (55 with SBI and 46 with ICI) with clinical suspicion of intussusception were enrolled. All clinicoradiological characteristics were compared between SBI and ICI. Univariate Logistic regression analysis was also used to assess the strength of associations. Receiver operating characteristic curves were constructed to determine optimal cut-off values, and the area under the curve (AUC) was calculated to evaluate diagnostic performance. Results: Age, sex, vomiting, and diarrhea were not significantly different between ICI and SBI cases ( P > 0.05). In contrast, abdominal pain, bloody stool, lymph nodes within the intussusception, free peritoneal fluid, length of intussusception (AUC: 0.94, sensitivity = 87%, specificity = 87%, cut-off point = 40 mm), lesion diameter (AUC: 0.96, sensitivity = 91%, specificity = 89%, cut-off point = 25 mm), fat core diameter (AUC: 0.91, sensitivity = 85%, specificity = 84%, cut-off point = 7 mm), outer wall thickness (AUC: 0.61, sensitivity = 74%, specificity = 53%, cut-off point = 5 mm), core-to-wall index (AUC: 0.93, sensitivity = 91%, specificity = 89%, cut-off point = 1.33), and core-to-wall index > 1 (AUC: 0.87, sensitivity = 93%, specificity = 80%, cut-off point = 1) were significantly higher in ICI than SBI cases ( P < 0.05). Conclusion: Our findings suggested that US is a reliable tool and demonstrates very high diagnostic utility in distinguishing SBI from ICI. Among them, the lesion diameter, length of intussusception, and core-to-wall index were the most useful variables. Therefore, ultrasound findings could assist clinicians beyond clinical symptoms and physical examination findings in an effective diagnosis and management of intussusception and in improving clinical decision-making.
- Open Access
- 1 August 2026
- Published by Brieflands in International Journal of Cancer Management
- Vol. 19 (1) , e168427
Association Between Computed Tomography Characteristics and Ultrasound-Based Risk Stratification in Incidental Thyroid Nodules of Oncologic Patients
Background: Incidental thyroid nodules (ITNs) are frequently detected in oncologic patients undergoing computed tomography (CT). However, the diagnostic accuracy of CT for these nodules, particularly in comparison with ultrasound-based Thyroid Imaging Reporting and Data System (TIRADS) and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) classifications, remains unclear. Objectives: We evaluated the diagnostic accuracy of CT for characterizing high-risk sonographic patterns in ITNs in oncologic patients by comparing CT findings with ultrasound-based classifications. Methods: This retrospective study analyzed 420 oncologic patients who underwent contrast-enhanced chest CT. Of the 65 patients with ITNs, 55 were included in the final analysis, comprising 81 nodules. CT findings, including density, enhancement, calcification, and size, were compared with the TIRADS and K-TIRADS ultrasound classifications. Fine-needle aspiration (FNA) was performed when indicated according to the K-TIRADS criteria. Statistical analyses included the intraclass correlation coefficient (ICC), chi-squared tests, logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: ROC analysis of enhancement-based prediction yielded an area under the curve of 0.86 (95% CI, 0.78 - 0.94) for K-TIRADS and 0.88 (95% CI, 0.80 - 0.94) for TIRADS. The optimal enhancement threshold for high-risk sonographic patterns was 38.8 Hounsfield units (HU). Diagnostic accuracy was 80.0% (95% CI, 69.0%-88.0%) for K-TIRADS and 78.0% (95% CI, 68.0%-87.0%) for TIRADS. Calcification was significantly associated with both TIRADS (P < 0.01) and K-TIRADS (P = 0.04). CT and ultrasound measurements of nodule size were strongly correlated (ICC = 0.96; P < 0.001). Follicular adenoma was the most common final diagnosis after FNA (63.2%). Conclusions: CT enhancement and calcification patterns provide complementary diagnostic value for ITNs in oncologic patients and may facilitate more targeted management. However, ultrasound remains essential for evaluating high-risk patterns. These findings suggest that CT may serve as a useful adjunct in ITN triage.
- 1 August 2026
- Published by Brieflands in International Journal of Cancer Management
- Vol. 19 (1) , e168427
Open AccessAssociation Between Computed Tomography Characteristics and Ultrasound-Based Risk Stratification in Incidental Thyroid Nodules of Oncologic Patients
Background: Incidental thyroid nodules (ITNs) are frequently detected in oncologic patients undergoing computed tomography (CT). However, the diagnostic accuracy of CT for these nodules, particularly in comparison with ultrasound-based Thyroid Imaging Reporting and Data System (TIRADS) and Korean Thyroid Imaging Reporting and Data System (K-TIRADS) classifications, remains unclear. Objectives: We evaluated the diagnostic accuracy of CT for characterizing high-risk sonographic patterns in ITNs in oncologic patients by comparing CT findings with ultrasound-based classifications. Methods: This retrospective study analyzed 420 oncologic patients who underwent contrast-enhanced chest CT. Of the 65 patients with ITNs, 55 were included in the final analysis, comprising 81 nodules. CT findings, including density, enhancement, calcification, and size, were compared with the TIRADS and K-TIRADS ultrasound classifications. Fine-needle aspiration (FNA) was performed when indicated according to the K-TIRADS criteria. Statistical analyses included the intraclass correlation coefficient (ICC), chi-squared tests, logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: ROC analysis of enhancement-based prediction yielded an area under the curve of 0.86 (95% CI, 0.78 - 0.94) for K-TIRADS and 0.88 (95% CI, 0.80 - 0.94) for TIRADS. The optimal enhancement threshold for high-risk sonographic patterns was 38.8 Hounsfield units (HU). Diagnostic accuracy was 80.0% (95% CI, 69.0%-88.0%) for K-TIRADS and 78.0% (95% CI, 68.0%-87.0%) for TIRADS. Calcification was significantly associated with both TIRADS (P < 0.01) and K-TIRADS (P = 0.04). CT and ultrasound measurements of nodule size were strongly correlated (ICC = 0.96; P < 0.001). Follicular adenoma was the most common final diagnosis after FNA (63.2%). Conclusions: CT enhancement and calcification patterns provide complementary diagnostic value for ITNs in oncologic patients and may facilitate more targeted management. However, ultrasound remains essential for evaluating high-risk patterns. These findings suggest that CT may serve as a useful adjunct in ITN triage.
- 9 July 2026
- Published by Springer Nature in Emergency Radiology
- Vol. 33 (5) , 1037-1046
Predictive role of ultrasonography in the early diagnosis of Hirschsprung’s disease in neonates and infants: an observational diagnostic study
We aimed to evaluate the diagnostic performance of conventional transabdominal ultrasound (US) in detecting Hirschsprung's disease (HD). This cross-sectional observational study enrolled infants (≤ six months) with clinical suspicion of HD. They subsequently underwent a standardized transabdominal US, followed by a confirmatory rectal biopsy. US parameters included the presence and location of a transition zone (TZ), proximal colonic dilation, upstream and downstream bowel lumen diameter and wall thickness, and luminal diameter ratio (LDR). Diagnostic performance metrics were calculated using histopathology as the reference standard. Of 72 infants (mean age: 25.9 ± 31.6 days; 37 (51.4%) females), 40 (55.6%) were diagnosed with HD. TZ on US showed the highest diagnostic performance (area under the curve (AUC) = 0.73 [0.63-0.83], sensitivity = 92%, specificity = 53%), followed by LDR (AUC = 0.66 [0.53-0.79], sensitivity = 82%, specificity = 56%) and upstream bowel wall thickness (AUC = 0.66 [0.52-0.79], sensitivity = 80%, specificity = 56%). Both LDR and upstream wall thickness were significantly higher in HD compared to non-HD infants (P = 0.02 for both). Demographic and perinatal characteristics did not differ significantly between groups (P > 0.05). Conventional transabdominal US demonstrates high sensitivity but moderate specificity for detecting HD in neonates and young infants. TZ, increased upstream bowel wall thickness, and elevated LDR are significant sonographic predictors. Therefore, although US may serve as a useful non-invasive triage or screening adjunct in clinically suspected cases of HD, it should not be considered a standalone diagnostic test, and rectal biopsy remains essential for definitive diagnosis.
- 9 July 2026
- Published by Springer Nature in Emergency Radiology
- Vol. 33 (5) , 1037-1046
Predictive role of ultrasonography in the early diagnosis of Hirschsprung’s disease in neonates and infants: an observational diagnostic study
We aimed to evaluate the diagnostic performance of conventional transabdominal ultrasound (US) in detecting Hirschsprung's disease (HD). This cross-sectional observational study enrolled infants (≤ six months) with clinical suspicion of HD. They subsequently underwent a standardized transabdominal US, followed by a confirmatory rectal biopsy. US parameters included the presence and location of a transition zone (TZ), proximal colonic dilation, upstream and downstream bowel lumen diameter and wall thickness, and luminal diameter ratio (LDR). Diagnostic performance metrics were calculated using histopathology as the reference standard. Of 72 infants (mean age: 25.9 ± 31.6 days; 37 (51.4%) females), 40 (55.6%) were diagnosed with HD. TZ on US showed the highest diagnostic performance (area under the curve (AUC) = 0.73 [0.63-0.83], sensitivity = 92%, specificity = 53%), followed by LDR (AUC = 0.66 [0.53-0.79], sensitivity = 82%, specificity = 56%) and upstream bowel wall thickness (AUC = 0.66 [0.52-0.79], sensitivity = 80%, specificity = 56%). Both LDR and upstream wall thickness were significantly higher in HD compared to non-HD infants (P = 0.02 for both). Demographic and perinatal characteristics did not differ significantly between groups (P > 0.05). Conventional transabdominal US demonstrates high sensitivity but moderate specificity for detecting HD in neonates and young infants. TZ, increased upstream bowel wall thickness, and elevated LDR are significant sonographic predictors. Therefore, although US may serve as a useful non-invasive triage or screening adjunct in clinically suspected cases of HD, it should not be considered a standalone diagnostic test, and rectal biopsy remains essential for definitive diagnosis.
- Open Access
- 6 June 2026
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 20 (1)
Scimitar syndrome and horseshoe lung presenting with syncope and hemoptysis in late childhood, management challenges, and outcomes: a case report
Background: Horseshoe lung (HL) and scimitar syndrome are rare congenital cardiopulmonary anomalies that may coexist, posing complex diagnostic and management challenges. The following case presents the clinical manifestation of repeated hemoptysis episodes and syncope, a combination that has rarely been reported in this context. Moreover, there were treatment challenges regarding the utility of minimally invasive techniques in the iatrogenic occlusion of aberrant vessels, which has more recently been suggested in the literature to yield comparable outcomes compared with open surgeries. Case presentation: We described the case of a 15-year-old Iranian boy who presented with syncope and hemoptysis following physical activity. Imaging findings were consistent with concomitant HL, partial anomalous pulmonary venous return (PAPVR), right lung hypoplasia, and scimitar syndrome. The patient successfully underwent transcatheter arterial embolization (TAE); however, another episode of hemoptysis occurred after three weeks. This recurrence indicated the failure of TAE and necessitated a right lower lobe segmentectomy. After the surgical excision, the patient showed improvement in respiratory status, with no further episodes of hemoptysis. He was discharged on postoperative day seven. At the 2-month follow-up, there were no signs of recurrence or complications. Nonetheless, the patient was scheduled for subsequent open-heart repair of the PAPVR defect. Conclusions: This case highlights that when HL or scimitar syndrome is identified, clinicians should be aware of associated congenital cardiopulmonary and vascular anomalies and perform a comprehensive clinical exam and multimodality imaging. Moreover, although TAE may yield outcomes comparable to open surgery with faster recovery and fewer postoperative complications, its effectiveness is questionable in patients with complex underlying conditions. Therefore, although the choice between the minimally invasive and invasive managements requires a multidisciplinary approach, it is recommended that patients with complications such as infections, bronchiectasis, large lumen aberrant vessels, multiple aberrant vessels, or unusual anatomies be planned for surgical resection of sequestrated lung tissue to avoid potentially less effective interventions.
- 6 June 2026
- Published by Springer Nature in Journal of Medical Case Reports
- Vol. 20 (1)
Open AccessScimitar syndrome and horseshoe lung presenting with syncope and hemoptysis in late childhood, management challenges, and outcomes: a case report
Background: Horseshoe lung (HL) and scimitar syndrome are rare congenital cardiopulmonary anomalies that may coexist, posing complex diagnostic and management challenges. The following case presents the clinical manifestation of repeated hemoptysis episodes and syncope, a combination that has rarely been reported in this context. Moreover, there were treatment challenges regarding the utility of minimally invasive techniques in the iatrogenic occlusion of aberrant vessels, which has more recently been suggested in the literature to yield comparable outcomes compared with open surgeries. Case presentation: We described the case of a 15-year-old Iranian boy who presented with syncope and hemoptysis following physical activity. Imaging findings were consistent with concomitant HL, partial anomalous pulmonary venous return (PAPVR), right lung hypoplasia, and scimitar syndrome. The patient successfully underwent transcatheter arterial embolization (TAE); however, another episode of hemoptysis occurred after three weeks. This recurrence indicated the failure of TAE and necessitated a right lower lobe segmentectomy. After the surgical excision, the patient showed improvement in respiratory status, with no further episodes of hemoptysis. He was discharged on postoperative day seven. At the 2-month follow-up, there were no signs of recurrence or complications. Nonetheless, the patient was scheduled for subsequent open-heart repair of the PAPVR defect. Conclusions: This case highlights that when HL or scimitar syndrome is identified, clinicians should be aware of associated congenital cardiopulmonary and vascular anomalies and perform a comprehensive clinical exam and multimodality imaging. Moreover, although TAE may yield outcomes comparable to open surgery with faster recovery and fewer postoperative complications, its effectiveness is questionable in patients with complex underlying conditions. Therefore, although the choice between the minimally invasive and invasive managements requires a multidisciplinary approach, it is recommended that patients with complications such as infections, bronchiectasis, large lumen aberrant vessels, multiple aberrant vessels, or unusual anatomies be planned for surgical resection of sequestrated lung tissue to avoid potentially less effective interventions.
- Open Access
- 1 June 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Physiological Responses During Phacoemulsification Cataract Surgery and Perceived Stress Among Ophthalmology Trainees: A Cross-Sectional Study
Background: Intraoperative stress can adversely affect surgical performance and trainee well-being, particularly in ophthalmic surgeries where micro-level precision plays a paramount role. This study aimed to evaluate both subjective measures of general perceived stress and objective physiological responses during phacoemulsification cataract surgery among ophthalmology trainees. Materials and Methods: In this cross-sectional study, 59 ophthalmology residents and fellows were enrolled. Objective physiological responses, including systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), and arterial oxygen saturation (SpO2), were recorded before and during key steps of surgery (incision, capsulorhexis, and lens removal with intraocular lens (IOL) implantation) by an ambulatory electrocardiograph (ECG) device. General perceived stress was also assessed during the preoperative resting period using the 14-item perceived stress scale (PSS-14). Results: SBP and HR increased significantly throughout the surgical steps, with the highest values observed during lens removal and IOL implantation (all P < 0.03). In contrast, changes in DBP and SpO2 were not statistically significant (P > 0.05). Less experienced trainees demonstrated higher overall DBP trends compared to more experienced counterparts (P = 0.01). Based on PSS-14 scores, female surgeons and those with lower levels of training reported significantly higher perceived stress (P = 0.04 and P < 0.001, respectively). Pre-operative propranolol use was associated with lower perceived stress (P = 0.02), although it did not significantly affect physiological parameters. Conclusion: Physiological responses in ophthalmology trainees increase during phacoemulsification cataract surgery, which may be translated into higher intra-operative stress. This increase is particularly higher in later stages, and is influenced by experience level and individual factors. As a result, these findings underscore the importance of implementing targeted strategies to enhance ophthalmology trainee well-being and improve surgical training environments, especially for individuals more susceptible to elevated stress levels.
- 1 June 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Open AccessPhysiological Responses During Phacoemulsification Cataract Surgery and Perceived Stress Among Ophthalmology Trainees: A Cross-Sectional Study
Background: Intraoperative stress can adversely affect surgical performance and trainee well-being, particularly in ophthalmic surgeries where micro-level precision plays a paramount role. This study aimed to evaluate both subjective measures of general perceived stress and objective physiological responses during phacoemulsification cataract surgery among ophthalmology trainees. Materials and Methods: In this cross-sectional study, 59 ophthalmology residents and fellows were enrolled. Objective physiological responses, including systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), and arterial oxygen saturation (SpO2), were recorded before and during key steps of surgery (incision, capsulorhexis, and lens removal with intraocular lens (IOL) implantation) by an ambulatory electrocardiograph (ECG) device. General perceived stress was also assessed during the preoperative resting period using the 14-item perceived stress scale (PSS-14). Results: SBP and HR increased significantly throughout the surgical steps, with the highest values observed during lens removal and IOL implantation (all P < 0.03). In contrast, changes in DBP and SpO2 were not statistically significant (P > 0.05). Less experienced trainees demonstrated higher overall DBP trends compared to more experienced counterparts (P = 0.01). Based on PSS-14 scores, female surgeons and those with lower levels of training reported significantly higher perceived stress (P = 0.04 and P < 0.001, respectively). Pre-operative propranolol use was associated with lower perceived stress (P = 0.02), although it did not significantly affect physiological parameters. Conclusion: Physiological responses in ophthalmology trainees increase during phacoemulsification cataract surgery, which may be translated into higher intra-operative stress. This increase is particularly higher in later stages, and is influenced by experience level and individual factors. As a result, these findings underscore the importance of implementing targeted strategies to enhance ophthalmology trainee well-being and improve surgical training environments, especially for individuals more susceptible to elevated stress levels.
- 5 May 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (9) , 5535-5546
Diagnostic value of the inner ear computed tomography measurements in detecting congenital sensorineural hearing loss: a comparative study
Congenital sensorineural hearing loss (CSNHL) is a very common subtype of pediatric hearing loss disorders. Less severe deformities in CSNHL might not be recognized during a simple visual inspection in computed tomography (CT) of the temporal bone. Therefore, the present study aimed to compare the inner ear measurements between CSNHL patients with grossly normal CT appearance and the healthy population. Children with confirmed CSNHL were enrolled along with a control group of healthy children. Their CT scans of the temporal bone were retrospectively reviewed. Ten inner ear radiologic measurements, including cochlea height (CH) and width (CW), width of cochlear nerve bony canal (WCN), superior and lateral semicircular canals (SSCC and LSCC) bony island widths, posterior semicircular canal (PSCC) inferior limb length, vestibule height (VH) and width (VW), and vestibular aqueduct (VA) width at the midpoint and operculum were compared between the two groups. 62 children (30 CSNHL, 37 females, mean age: 7.1 ± 3.4 years) were included. The intra-observer repeatability was very good to excellent across all parameters (Intraclass correlation coefficient: 0.83-0.96). CH (P ≤ 0.001) and VA midpoint width (P ≤ 0.001) were significantly higher in CSNHL patients than healthy individuals, and WCN (P ≤ 0.001), SSCC bony island width (P ≤ 0.001) and LSCC bony island width (P = 0.01) were significantly lower. There was no statistically significant difference in terms of CW (P = 0.83), PSCC inferior limb length (P = 0.54), VH (P = 0.67), VW (P = 0.83), and VA operculum width (P = 0.15). WCN (ROC-AUC: 0.80, cut-off point = 1.9 mm, sensitivity = 60%, specificity = 84%) and VA midpoint width (ROC-AUC: 0.80, cut-off point = 1 mm, sensitivity = 77%, specificity = 75%) demonstrated the highest diagnostic utility in identifying CSNHL, followed by CH, SSCC and LSCC bony island widths. Inner ear radiologic measurements, particularly WCN and VA midpoint width, demonstrate relatively high diagnostic value in identifying CSNHL with subtle malformations on temporal bone CT.
- 5 May 2026
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 283 (9) , 5535-5546
Diagnostic value of the inner ear computed tomography measurements in detecting congenital sensorineural hearing loss: a comparative study
Congenital sensorineural hearing loss (CSNHL) is a very common subtype of pediatric hearing loss disorders. Less severe deformities in CSNHL might not be recognized during a simple visual inspection in computed tomography (CT) of the temporal bone. Therefore, the present study aimed to compare the inner ear measurements between CSNHL patients with grossly normal CT appearance and the healthy population. Children with confirmed CSNHL were enrolled along with a control group of healthy children. Their CT scans of the temporal bone were retrospectively reviewed. Ten inner ear radiologic measurements, including cochlea height (CH) and width (CW), width of cochlear nerve bony canal (WCN), superior and lateral semicircular canals (SSCC and LSCC) bony island widths, posterior semicircular canal (PSCC) inferior limb length, vestibule height (VH) and width (VW), and vestibular aqueduct (VA) width at the midpoint and operculum were compared between the two groups. 62 children (30 CSNHL, 37 females, mean age: 7.1 ± 3.4 years) were included. The intra-observer repeatability was very good to excellent across all parameters (Intraclass correlation coefficient: 0.83-0.96). CH (P ≤ 0.001) and VA midpoint width (P ≤ 0.001) were significantly higher in CSNHL patients than healthy individuals, and WCN (P ≤ 0.001), SSCC bony island width (P ≤ 0.001) and LSCC bony island width (P = 0.01) were significantly lower. There was no statistically significant difference in terms of CW (P = 0.83), PSCC inferior limb length (P = 0.54), VH (P = 0.67), VW (P = 0.83), and VA operculum width (P = 0.15). WCN (ROC-AUC: 0.80, cut-off point = 1.9 mm, sensitivity = 60%, specificity = 84%) and VA midpoint width (ROC-AUC: 0.80, cut-off point = 1 mm, sensitivity = 77%, specificity = 75%) demonstrated the highest diagnostic utility in identifying CSNHL, followed by CH, SSCC and LSCC bony island widths. Inner ear radiologic measurements, particularly WCN and VA midpoint width, demonstrate relatively high diagnostic value in identifying CSNHL with subtle malformations on temporal bone CT.
- 13 April 2026
- Published by Springer Nature in International Ophthalmology
- Vol. 46 (1) , 204
Agreement of wavefront-based refraction with autorefraction and manifest refraction across refractive and astigmatic profiles in refractive surgery candidates
Background To assess the agreement between wavefront-based refraction (WFR) using a pyramidal aberrometer (PERAMIS) and conventional non-cycloplegic (NCR), cycloplegic (CR), and manifest refraction (MR) techniques across refractive types and astigmatic axes. Methods This cross-sectional study evaluated 111 right eyes of refractive surgery candidates. WFR from PERAMIS was compared with NCR, CR, and MR for sphere, cylinder, spherical equivalent (M), blur (B), and astigmatic vectors (J0, J45). Subgroup analyses examined ametropia status, myopia severity, and astigmatic axis. Results A consistent refractive trend: CR < MR < NCR < WFR was observed for M, even within the subgroups. WFR consistently yielded more myopic measurements than CR, MR, and NCR (M-MD: − 0.56 D (p < 0.001), − 0.39 D (p < 0.001), and − 0.10 D (p < 0.05), respectively). WFR demonstrated excellent correlation with NCR (ICC = 0.98), CR (ICC = 0.96), and MR (ICC = 0.97) for M. This correlation remained high for other refractive components (ICC > 0.90) except J45, where moderate correlation was observed (ICC: 0.75–0.82). The correlation was superior in myopic eyes (ICC values > 0.90 except for J45; MDs almost < 0.50 D) compared to hyperopic eyes (ICC values ranging from 0.71 (WFR-MR cylinder) to 0.93 (WFR-NCR sphere, MDs < 0.75 D). Furthermore, WFR showed an excellent correlation with NCR, CR, and MR across astigmatism types (M: ICCs: 0.93–0.99, MDs < 0.75 D). Despite the high correlation, the limits of agreement (LoA) were wide in the whole population, especially for WFR-CR (LoA for M: − 1.67:0.55 D) and WFR-MR (LoA for M: − 1.41:0.63 D), with similar patterns across all subgroups. Conclusion Pyramidal WFR may be a valuable complement to conventional refractive measurements, particularly in patients with myopia. However, its tendency toward myopic bias and wide LoAs limits its interchangeability with CR or MR. Clinicians should interpret WFR cautiously, especially in hyperopic eyes, and consider confirming measurements with subjective methods. These findings support the utility of pyramidal WFR as an efficient initial estimate in refractive evaluations, especially for surgical screening, but not as a standalone replacement for traditional refraction.
- 13 April 2026
- Published by Springer Nature in International Ophthalmology
- Vol. 46 (1) , 204
Agreement of wavefront-based refraction with autorefraction and manifest refraction across refractive and astigmatic profiles in refractive surgery candidates
Background To assess the agreement between wavefront-based refraction (WFR) using a pyramidal aberrometer (PERAMIS) and conventional non-cycloplegic (NCR), cycloplegic (CR), and manifest refraction (MR) techniques across refractive types and astigmatic axes. Methods This cross-sectional study evaluated 111 right eyes of refractive surgery candidates. WFR from PERAMIS was compared with NCR, CR, and MR for sphere, cylinder, spherical equivalent (M), blur (B), and astigmatic vectors (J0, J45). Subgroup analyses examined ametropia status, myopia severity, and astigmatic axis. Results A consistent refractive trend: CR < MR < NCR < WFR was observed for M, even within the subgroups. WFR consistently yielded more myopic measurements than CR, MR, and NCR (M-MD: − 0.56 D (p < 0.001), − 0.39 D (p < 0.001), and − 0.10 D (p < 0.05), respectively). WFR demonstrated excellent correlation with NCR (ICC = 0.98), CR (ICC = 0.96), and MR (ICC = 0.97) for M. This correlation remained high for other refractive components (ICC > 0.90) except J45, where moderate correlation was observed (ICC: 0.75–0.82). The correlation was superior in myopic eyes (ICC values > 0.90 except for J45; MDs almost < 0.50 D) compared to hyperopic eyes (ICC values ranging from 0.71 (WFR-MR cylinder) to 0.93 (WFR-NCR sphere, MDs < 0.75 D). Furthermore, WFR showed an excellent correlation with NCR, CR, and MR across astigmatism types (M: ICCs: 0.93–0.99, MDs < 0.75 D). Despite the high correlation, the limits of agreement (LoA) were wide in the whole population, especially for WFR-CR (LoA for M: − 1.67:0.55 D) and WFR-MR (LoA for M: − 1.41:0.63 D), with similar patterns across all subgroups. Conclusion Pyramidal WFR may be a valuable complement to conventional refractive measurements, particularly in patients with myopia. However, its tendency toward myopic bias and wide LoAs limits its interchangeability with CR or MR. Clinicians should interpret WFR cautiously, especially in hyperopic eyes, and consider confirming measurements with subjective methods. These findings support the utility of pyramidal WFR as an efficient initial estimate in refractive evaluations, especially for surgical screening, but not as a standalone replacement for traditional refraction.