Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luca Di Stefano has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    CORRIGENDUM: Hybrid additive manufacturing and data-guided design of graded scaffolds for soft-to-hard tissues engineering (2026 Biomed. Mater. 21 015013)

    by Simone Micalizzi, Alberto Bevilacqua, Luca Di Stefano, Francesco De Gaetano, Federica Potere, Arianna Callera, Edoardo D’IMprima, Martin Centola, Alberto Favaro, Daniele D’ARrigo, et al.

    CORRIGENDUM: Hybrid additive manufacturing and data-guided design of graded scaffolds for soft-to-hard tissues engineering (2026 Biomed. Mater. 21 015013), Micalizzi, Simone, Bevilacqua, Alberto, Di Stefano, Luca, De Gaetano, Francesco, Potere, Federica, Callera, Arianna, D’Imprima, Edoardo, Centola, Martin, Favaro, Alberto, D’Arrigo, Daniele, Bonanzinga, Tommaso, Marcacci, Maurilio, Oliva, Paolo

  • Open Access

    And Artificial Intelligence Created the Polyps….

    by Tommy Rizkala, Luca Di Stefano, Cesare Hassan

  • Open Access

    AI in High-Frequency Micro-Ultrasound: Advancing Prostate Imaging from Segmentation to Cancer Detection

    by Ludovica Cella, Marco Paciotti, Pier Paolo Avolio, Vittorio Fasulo, Andrea Piccolini, Rebecca Canneto, Giacomo Cavadini, Luca Di Stefano, Alberto Saita, Paolo Casale, et al.

    Background/Objective: High-frequency micro-ultrasound (micro-US) offers real-time, high-resolution imaging for prostate cancer. Although artificial intelligence (AI) has shown potential in enhancing micro-US interpretation, a comprehensive review of this emerging field is currently missing. This review synthesizes current evidence on AI applied to ExactVu 29 MHz micro-US for prostate cancer. Methods: PubMed/MEDLINE, Embase, Scopus, Web of Science and the Cochrane Library were searched up to December 2025. Studies were included if they applied machine learning or deep learning directly to 29 MHz micro-US data and reported quantitative performance metrics. Results: Ten studies met the inclusion criteria: six on prostate cancer detection, three on prostate segmentation and one on micro-US–histopathology registration. Detection models ranged from classical quantitative ultrasound machine learning to deep architectures using self-supervision, transformers, multiple-instance learning, ensemble calibration and 3D segmentation-based pipelines. Among core-level models for clinically significant cancer, area under the receiver operating characteristic curve (AUROC) values clustered around 0.76–0.81; one lesion-level framework reported an AUROC of 0.92, though at a non-comparable analytical unit. Segmentation studies achieved accurate prostate delineation (Dice similarity coefficient ≈ 0.94), and a single study demonstrated high-precision 3D registration to whole-mount histopathology (Dice similarity coefficient 0.97 and landmark error < 3 mm). All studies evaluated AI on previously acquired data, without real-time clinical implementation. Conclusions: AI for micro-US shows promising and reproducible early results across detection, segmentation and registration, but evidence is still limited. In view of the potential of AI to optimize micro-US utilization and its related advantages, additional efforts are warranted to achieve clinical adoption.


  • Open Access

    Enhancing accuracy and explainability in colorectal lesion classification with attention-supervised Vision Transformers

    by Luca Carlini, Luca Di Stefano, Chiara Lena, Davide Massimi, Tommy Rizkala, Cesare Hassan, Elena De Momi


  • Open Access

    Hybrid additive manufacturing and data-guided design optimization for graded anterior cruciate ligament engineering

    by Simone Micalizzi, Alberto Bevilacqua, Luca Di Stefano, Francesco De Gaetano, Federica Potere, Arianna Callera, Edoardo D’iMprima, Martin Centola, Alberto Favaro, Daniele D’aRrigo, et al.

    Interface tissues, such as the enthesis connecting ligaments to bone, present multiphasic architectures with continuous gradients in structure, composition, and mechanics. Engineering such complex transitions remains a major challenge in biofabrication. This study aims to develop a hybrid manufacturing and machine learning (ML)-guided design strategy to create functionally graded scaffolds for anterior cruciate ligament (ACL) reconstruction. A hybrid biofabrication platform was used to integrate extrusion-based three-dimensional printing and electrospinning within a single workflow. Polycaprolactone was used as the common biomaterial for both modalities. Four scaffold designs, varying in electrospun midsection length, slit patterning, and core geometry, were fabricated to replicate the native ACL’s zonal architecture. Scaffolds were characterized through scanning electron microscopy (SEM) and uniaxial tensile testing. Resulting data were used to train a ML model to predict mechanical performance from geometric features. The model was then used to generate a fifth scaffold design optimized for enhanced performance. The hybrid process successfully fabricated multiscale scaffolds with integrated bone-like, enthesis-like, and ligament-like regions. SEM confirmed morphological integration between printed and electrospun structures. Mechanical testing revealed design-dependent variations in strength and stiffness. The ML model identified slit number and outer diameter as key predictors and guided the design of an optimized scaffold that combined the compliance of slitted geometries with enhanced mechanical strength. The ML-optimized scaffold achieved the highest tensile force among the slitted designs and improved stiffness compared to the other slitted configurations this study demonstrates a predictive and performance-driven biofabrication strategy that integrates hybrid additive manufacturing and ML. The approach enables rational scaffold optimization, reduces empirical iterations, and supports the development of biomimetic constructs for soft-to-hard tissue engineering. While focused on ACL reconstruction, the workflow is adaptable to a wide range of tissue interfaces.


  • Open Access

    Large language model for interpreting the Paris classification of colorectal polyps

    by Davide Massimi, Luca Carlini, Yuichi Mori, Luca Di Stefano, Giulio Antonelli, Tommy Rizkala, Marco Spadaccini, Roberto de Sire, Ludovico Alfarone, Chiara Lena, et al.

    Reporting of colorectal polyp morphology using the Paris classification is often inaccurate. Multimodal large language models (M-LLMs) may support morphological assessment. This study aimed to evaluate the accuracy of an M-LLM (GPT-4o) in classifying colorectal polyp morphology compared with expert and non-expert endoscopists.We used the SUN dataset of colonoscopy videos from 100 unique colorectal polyps, each labeled with the validated Paris classification. An M-LLM (GPT-4o) classified five representative frames per lesion. Three expert and three non-expert endoscopists, blinded to one another, performed the same task. The primary outcome was accuracy in differentiating non-polypoid (IIa/IIc) from polypoid (Is/Ip/Isp) lesions. The secondary outcome was accuracy in differentiating sessile (Is) from pedunculated (Ip/Isp) lesions. Given the exploratory design, no multiplicity correction was applied; point estimates are presented with 95% confidence intervals (CIs), and P values are interpreted descriptively.M-LLM accuracy for differentiating non-polypoid from polypoid lesions was 73% (95% CI 63%-81%), comparable to experts (75%, 65%-83%; P = 0.84) and non-experts (77%, 68%-85%; P = 0.52), with similar sensitivity and specificity. Accuracy for differentiating sessile from pedunculated lesions was 55% (95% CI 42%-67%), lower than experts (76%; P = 0.02) and non-experts (77%; P = 0.01), primarily due to poor specificity (12% vs. experts 82% and non-experts 88%; P < 0.01 for both comparisons).M-LLMs performed comparably to endoscopists in distinguishing non-polypoid from polypoid lesions but failed to reliably identify pedunculated morphology.